ETC2 CTF100 Coaxial cables used in cabled distribution networks designed according the european Datasheet

TECHNICAL DATA SHEET
COAX CTF100
Code
version
date
page
CTF100
1
2008-04-09
1/2
APPLICATION
Coaxial cables used in cabled distribution networks designed according the European
Standard EN 50117-2-1 and En 50117-2-4 operating at frequencies between 5 MHz and 3000
MHz.
CONSTRUCTION
1 2 3.1 3.2
4
1
2
3.1
3.2
4
Solid soft annealed copper
Gas injected LDPE
Copper-polyester foil
Annealed copper
PVC according the European Standard HD 624.
Inner conductor
Dielectric
Foil
Braid
Sheath
REQUIREMENTS AND TEST METHODS
Test methods in accordance with European standard EN 50117-1.
Mechanical characteristics
1. Inner conductor.
Diameter:
2. Dielectric:
Diameter:
Adhesion:
3. Outer conductor:
Diameter screen:
Coverage braid:
4. Sheath:
Diameter:
Tensile strength:
Elongation at break:
5. Cable:
Storage/operation temperature:
Minimum installation temperature:
Minimum static bend radius:
0.96 mm ± 0.02 mm
4.7 mm ± 0.15 mm
7.5 – 75 N at 25 mm
5.35 mm ± 0.15 mm
55 % ± 5 %
6.65 mm ± 0.2 mm
≥ 12.5 N/mm2
≥ 150 %
-40°C to +70°C
-5 °C
35 mm
 Belden Wire & Cable B.V.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner
TECHNICAL DATA SHEET
COAX CTF100
Code
version
date
page
CTF100
1
2008-04-09
2/2
Electrical characteristics
Mean characteristic impedance:
Regularity of impedance:
DC loop resistance:
DC resistance inner conductor:
DC resistance outer conductor:
Capacitance:
Velocity ratio:
Insulation resistance:
Voltage test of dielectric:
Screening efficiency after flexing
30-1000 MHz:
1000 – 2000 MHz:
2000 – 3000 MHz:
Return loss at
5-30 MHz:
30-470 MHz:
470-1000 MHz:
1000-2000 MHz:
2000-3000 MHz:
75 ± 3 Ω
>40dB or <1%
≤ 41 Ohm/km
≤ 26 Ohm/km
≤ 15 Ohm/km
55.0 pF/m ± 2.0 pF/m
0.82 ± 0.02
> 104 MOhm.km
2 kVdc
≥ 75 dB
≥ 65 dB
≥ 55 dB
≥ 20 dB*
≥ 20 dB*
≥ 18 dB*
≥ 16 dB*
≥ 15 dB*
*Max. 3 peak values 4 dB lower than specified.
Attenuation at
5 MHz:
50 MHz:
100 MHz:
200 MHz:
460 MHz:
800 MHz:
Maximal
1.6 dB/100m
4.6 dB/100m
6.5 dB/100m
9.5 dB/100m
15.0 dB/100m
18.8 dB/100m
Attenuation at
860 MHz:
1000 MHz:
1750 MHz:
2150 MHz:
2400 MHz:
3000 MHz:
REVISIONS
# Description
Maximal
19.5 dB/100m
21.5 dB/100m
29.0 dB/100m
32.5 dB/100m
34.4 dB/100m
38.4 dB/100m
Date
Initials
Belden CDT believes this product to be in compliance with the environmental regulations EU RoHS (Directive 2002/95/EC,
27 January 2003); this is valid for all material produced after the RoHS compliant date for this product.