PHOENIX EMD-BL-PTC-PT Electronic monitoring relay for temperature monitoring Datasheet

EMD-BL-PTC(-PT)
Electronic monitoring relay for temperature monitoring
Data sheet
107385_en_00
1
© PHOENIX CONTACT - 2016-05-10
Description
Features
Safety and system availability requirements are constantly on –
the increase – across all industries. Processes are becoming
more and more complex, not only in machine building and the
chemical industry but also in building technology. The demands placed on energy technology are also constantly on
the rise.
It is only by continuously monitoring key network and system
parameters that error-free and therefore cost-effective operation can be achieved. Electronic monitoring relays from the
EMD series are available for a wide range of monitoring tasks
so that the consequences of errors can be avoided or kept within limits.
The operating states are signaled via color LEDs and any errors that occur can be sent to a controller via a floating contact
or can shut down a section of the system. All device versions
are equipped with response delays so that measured values
outside the set monitoring range can be briefly tolerated.
Winding temperature monitoring
WARNING: Risk of electric shock
Never carry out work when voltage is present.
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products.
EMD-BL-PTC(-PT)
2
Ordering data
Description
Type
Order No.
Electronic monitoring relay for temperature monitoring
EMD-BL-PTC-PT
2906253
1
Electronic monitoring relay for temperature monitoring
EMD-BL-PTC
2906252
1
3
Pcs./Pkt.
Technical data
Input data
Input name
Measuring input
Maximum input voltage
≤ 4 V DC (connection terminal blocks: T1 and T2)
Maximum temperature coefficient
< 0.05 %/K
Function
Winding temperature monitoring
Basic accuracy
± 10 % (of scale end value)
Total cold resistance
≤ 1.5 kΩ
Response value
≥ 3.6 kΩ (Relay drops out)
Release value
≤ 1.6 kΩ (Relay picks up)
Short-circuit detection
< 20 Ω
Recovery time
> 300 ms
Output data
Contact type
1 floating PDT
Maximum switching voltage
250 V AC (in acc. with IEC 60947-5-1)
Interrupting rating (ohmic load) max.
1250 VA (5 A/250 V AC)
Output fuse
5 A (fast-blow)
Supply
Supply voltage
230 V AC (-15 % ... +10 %)
Frequency range
50 Hz ... 60 Hz
Nominal power consumption
3.5 VA (0.5 W)
General data
Mechanical service life
15 x 106 cycles
Service life, electrical
1 x 105 cycles
Switching frequency
≤6
Voltage drop
> 30 % (Relative to the supply voltage)
Operating mode
100% operating factor
Degree of protection
IP40 (housing) / IP20 (connection terminal blocks)
Degree of pollution
2 (IEC 60947-5-1)
Overvoltage category
III (IEC 60947-5-1)
Mounting
on standard DIN rail NS 35 in accordance with EN 60715
Mounting position
any
Width
17.5 mm
Height
88 mm
Depth
65.5 mm
Type of housing
Polyamide PA66, self-extinguishing
Color
gray
107385_en_00
PHOENIX CONTACT
2
EMD-BL-PTC(-PT)
Connection data
Push-in-/Spring-cage
connection
Screw connection
Conductor cross section, solid
0.14 mm² ... 2.5 mm²
0.5 mm² ... 2.5 mm²
Conductor cross section, flexible
0.14 mm² ... 2.5 mm²
0.5 mm² ... 2.5 mm²
AWG
26 ... 14
20 ... 14
Stripping length
8 mm
8 mm
Tightening torque
1 Nm
Ambient conditions
Ambient temperature (operation)
-25 °C ... 55 °C
Ambient temperature (storage/transport)
-25 °C ... 70 °C
Permissible humidity (operation)
15 % ... 85 %
Climatic class
Conformance / approvals
Conformance
CE-compliant
UL, USA / Canada

Conformance with EMC Directive 2004/108/EC (valid until April 19, 2016) / 2014/30/EU (valid from April 20, 2016)
Noise immunity according to
EN 61000-6-2
Noise emission according to
EN 61000-6-3
Conformance with Low Voltage Directive 2006/95/EC (valid until April 19, 2016) / 2014/35/EU (valid from April 20, 2016)
Low voltage switchgear according to
107385_en_00
EN 60947-5-1
PHOENIX CONTACT
3
EMD-BL-PTC(-PT)
4
Block diagram
U = 230 V AC
12 14
T1
T2
11
A1
5
A2
Safety notes
WARNING: Risk of electric shock
Never carry out work when voltage is present.
6
Structure
1
2
3
A1
LED: failure
LED: supply U
Snap-on foot for DIN rail mounting
A2
T1
3
T2
2
EMD-BL-PTC-PT
1
Failure
U
7
Installation
WARNING: Risk of electric shock
Never carry out work when voltage is present.
The module can be snapped onto all 35 mm DIN rails according to EN 60715.
107385_en_00
PHOENIX CONTACT
4
EMD-BL-PTC(-PT)
8
Diagnostics
The LEDs indicate the following error states:
"U" LED (Green)
–
LED ON: Supply voltage present
"Failure" LED (red):
–
LED ON: indicates error
9
Connection examples
U
A1
A2
T1
T2
A1
11
R
A2 12 14
11
12
10
14
Function
Temperature Monitoring of the Motor Winding
LED
FAILURE
3,6 k
1,6 k
PTC
R
107385_en_00
If the PTC total resistance is less than 3.6 kΩ (normal temperature of the motor) when the supply voltage is applied, the
output relay R activates. If the total resistance rises over
3.6 kΩ, the output relay R deactivates. The output relay R reactivates when the PTC total resistance has fallen below
1.6 kΩ.
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany
phoenixcontact.com
5
Similar pages