AIMTEC AMEPR30C-5070AZ Led driver / converter Datasheet

Click on Series name for product info on aimtec.com
Series AMEPR30C-AZ
up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
Models
Single output
• AC-DC Constant Current or Constant
Voltage LED Driver
• Input range 90-305VAC/47-440Hz
• High efficiency up to 83%
• Operating temperature -40 to 85°C
• Dimmable via resistive / 0-10Vdc / PWM
• 5 Years Limited Warranty
•
•
•
•
•
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
AMEPR30C-5070AZ
35
36-50
0.7
90-305/47-440
130-430
AMEPR30C-4864AZ
30.7
36-48
0.64
90-305/47-440
130-430
AMEPR30C-36100AZ
36
24-36
1
90-305/47-440
130-430
AMEPR30C-24140AZ
33.6
12-24
1.4
90-305/47-440
130-430
AMEPR30C-12250AZ
30
5-12
2.5
90-305/47-440
130-430
Model
①
Over temperature protection
Over current protection
Waterproof case rated IP68
Power Factor Correction
Short circuit protection
Mode of Operation
Efficiency
(%)
115
230
277
83
83
83
83
83
83
82
82
80
80
83
83
83
83
83
83
82
82
80
80
83
83
83
83
83
83
82
82
80
80
VAC
Constant Current
②
Constant Voltage
Constant Current
②
Constant Voltage
Constant Current
②
Constant Voltage
Constant Current
②
Constant Voltage
Constant Current
②
Constant Voltage
VAC
VAC
Exceeding the maximum output power will permanently damage the converter.
The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No
dimming option in the case.
③
In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models
can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number when
ordering.
②
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-sale
AMEPR30C-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
Power factor
External fuse
Start-up time
www.aimtec.com
F 052.1e R3.C
Conditions
Typical
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
0.96
0.90
0.85
1
450
Tel: +1 514 620 2722
1 of 9
Maximum
430
250
210
25
40
55
0.25
3.5
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR30C-AZ
Output Specifications
Parameters
Current accuracy
Line regulation
Load regulation
Ripple & Noise*
Hold-up time
Current adjustment range
up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
Conditions
Typical
Maximum
±3
±2
±3
100
50
100-10
(LL-HL)
0-100% load
Units
%
%
%
mV p-p
ms
%
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor.
Isolation Specifications
Parameters
Tested voltage
Isolation Resistance
I/O
I/FG
O/FG
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Over temperature protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Potting
Wires
Weight
Dimensions
MTBF
Conditions
Typical
500VDC
>1000
3sec
Conditions
Rated
Units
3750
2000
500
VAC
VAC
VAC
MΩ
Typical
130
≧105
≧105
Auto recovery
125°C
Refer to model application
Detect case temperature
With derating over °C
Maximum
Units
100
C
C
o
C
o
C
% / oC
KHz
%
%
o
o
-40 to +95
±0.02
Free air convection
Non condensing
20~95
Plastic
Epoxy (IP68 rated)
UL1015 18AWG * 20CM
540
137.33 x 60 x 40.50 mm (5.41 x 2.36 x 1.59 inches)
>400,000 hrs (MIL-HDBK-217F at t=+25°C)
% RH
g
Safety Specifications
Parameters
Agency approvals
Standards
www.aimtec.com
F 052.1e R3.C
cULus, CE
UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13
Information Technology Equipment
EN55022 Class B
Harmonic Current Emissions
IEC/EN 61000-3-2, Class C
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2 Level 3
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 2
Electrical Fast Transient / Burst Immunity
IEC 61000-4-4 Level 2
Surge Immunity
IEC 61000-4-5 Level 3
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8 Level 1
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Tel: +1 514 620 2722
2 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR30C-AZ
up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
Dimensions














£X
1.00 (£ X
0.04)





























  
  ¡ Ó
 ¡ Ó



Analog (Resistive) Dimming Application Circuit
AC
BROWN
L
GREEN
+Vout
AMEPR30-AZ
BLUE
N
F 052.1e R3.C
1
1st LED
BLUE
Model Number
AMEPR30C-5070AZ
-Vout
AMEPR30C-4864AZ
1
WHITE
www.aimtec.com
RED
BLACK
AMEPR30C-36100AZ
AMEPR30C-24140AZ
Pot
AMEPR30C-12250AZ
Tel: +1 514 620 2722
3 of 9
Maximum Pot
Value (kΩ)
See graphs
below
See graphs
below
See graphs
below
See graphs
below
See graphs
below
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR30C-AZ
Dimming Performance Graphs
AMEPR30C-4864AZ
www.aimtec.com
F 052.1e R3.C
up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
Tel: +1 514 620 2722
4 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR30C-AZ
AMEPR30C-5070AZ
www.aimtec.com
F 052.1e R3.C
up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
Tel: +1 514 620 2722
5 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR30C-AZ
AMEPR30C-12250AZ
www.aimtec.com
F 052.1e R3.C
up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
Tel: +1 514 620 2722
6 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR30C-AZ
AMEPR30C-24140AZ
www.aimtec.com
F 052.1e R3.C
up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
Tel: +1 514 620 2722
7 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR30C-AZ
AMEPR30C-36100AZ
www.aimtec.com
F 052.1e R3.C
up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
Tel: +1 514 620 2722
8 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEPR30C-AZ
up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
Derating
Free Air Convection
55 º C
100
80
Safe Operating Area
60
40
20
0
-40
-20
0
20
40
60
80
85
100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R3.C
Tel: +1 514 620 2722
9 of 9
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages