AIMTEC AMER90C-50180CAZ Led driver / converter Datasheet

Click on Series name for product info on aimtec.com
Series AMER90C-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
Models
Single output
•
•
•
•
•
•
•
Constant current LED Driver or Converter
Input range 90-305VAC/47-440Hz
High Efficiency up to 91%
115VAC Operating temperature -50 to 85°C
230VAC Operating temperature -55 to 85°C
Dimmable via resistive / 0-10Vdc / PWM
5 Years Limited Warranty
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
AMER90C-50180CAZ
90
36-50
1.8
90-305/47440
130-430
AMER90C-36250CAZ
90
24-36
2.5
90-305/47440
130-430
AMER90C-24375CAZ
90
12-24
3.75
90-305/47440
130-430
Model
•
•
•
•
•
Over Temperature Protection
Waterproof Case rated IP68
Power Factor Correction
Short Circuit Protection
Over Current Protection
Mode of Operation
Efficiency
(%)
115
230
277
Constant Current
②
Constant Voltage
Constant Current
87
88
86
87
86
87
87
87
87
Constant Voltage
Constant Current
88
87
87
86
86
86
Constant Voltage
87
86
86
VAC
②
②
VAC
VAC
①
Exceeding the maximum output power will permanently damage the converter.
②
The dimming feature is not supported when units are used in Constant Voltage mode only,
③
In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All
models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number
when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified.
See http://www.aimtec.com/terms-sale
AMER90C-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms(cold start)
Leakage current
Power factor
External fuse
Start-up time
www.aimtec.com
F 052.1e R3.B
Conditions
Typical
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
0.98
0.94
0.90
2.5
1000
Tel: +1 514 620 2722
1 of 6
Maximum
1500
600
500
40
50
60
0.25
3.5
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90C-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Conditions
Typical
Rated
Units
500VDC
>1000
Current accuracy
±3
%
Line regulation
(LL-HL)
±2
%
Load regulation
0-100% load
±3
%
Ripple & Noise*
150
mV p-p
Hold-up time
100
ms
Current adjustment range
100-10
%
④Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor.
Isolation Specifications
Parameters
Tested voltage
Isolation resistance
I/O
I/FG
O/FG
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
Over temperature protection
Operating temperature
(See Derating Table)
Cold Start-up Time
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Potting
Wires
Weight
Dimensions (L X H X W)
MTBF
3sec
Conditions
3750
2000
500
VAC
VAC
VAC
MΩ
Typical
Maximum
125
≧105
≧105
Continuous
Auto recovery
>105°C
-50 to +85
-55 to +85
(115VAC)
(230VAC)
-55°C
Units
KHz
%
%
o
35
100
C
C
Sec
o
C
o
C
% / oC
95
% RH
o
-55 to +95
±0.02
Free air convection
Aluminum
Epoxy (IP68 rated)
UL1015 18AWG Input & 14AWG Output *20CM
900
7.13 x 2.32 x 1.85 inches
181.00 x 59.00 x 47.00 mm
>400,000 hrs (MIL-HDBK-217F at +25°C)
g
Safety Specifications
Parameters
Agency approvals
Standards
www.aimtec.com
F 052.1e R3.B
CE
EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13
Note: also designed to meet cULus, UL8750, UL60950-1
Tel: +1 514 620 2722
2 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90C-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
Dimensions
Top View
181.00
(7.13)
4.00
(0.16)
41.00
(1.73)
27.00
(1.06)
8.00
(0.32)
11.00
(0.43)
23.00
(0.91)
End View
Side View
200.00
(8.00)
200.00
(8.00)
47.00
(1.85)
59.00
(2.32)
2.30
(0.09)
Input/Output Wires are 18 AWG 20cm
Measurements in Millimeters (inch)
Case Tolerance: ±0.5 (±0.02)
Temperature graph
Free Air Convection
55 º C
100
80
Safe Operating Area
60
40
20
0
-40
-20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 052.1e R3.B
Tel: +1 514 620 2722
3 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90C-CAZ
Dimming Performance
AMER90C-24375CAZ
www.aimtec.com
F 052.1e R3.B
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
Tel: +1 514 620 2722
4 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90C-CAZ
AMER90C-36250CAZ
www.aimtec.com
F 052.1e R3.B
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
Tel: +1 514 620 2722
5 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90C-CAZ
AMEPR90C-50180CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R3.B
Tel: +1 514 620 2722
6 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only