AIMTEC AMES15-MAZ-1 Screw terminals on input & output Datasheet

Click on Series name for product info on aimtec.com
Series AMES15-MAZ
15 Watt | AC-DC / DC-DC Converter
FEATURES:





Screw Terminals on Input & Output
Operating temperature: -40 to +80°C
Over load, Over Voltage, Short Circuit Protection
Optional DIN Rail mounting bracket
Universal input: 90-264VAC, 47-440Hz





RoHS compliant
Soft start
Energy Star compliant
CE, cULus, CB approvals
4000VAC I/O Isolation
CB
Models
Single output
Model
Input Voltage
(VAC/Hz)
AMES15-3.3SMAZ
AMES15-5SMAZ
AMES15-12SMAZ
AMES15-15SMAZ
AMES15-24SMAZ
Input
voltage
(VDC)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
130-370
130-370
130-370
130-370
130-370
Input Voltage
(VAC/Hz)
Input
voltage
(VDC)
Max
Output
wattage
Output
Voltage
(V)
(W)
9.9
15
15
15
15
3.3
5
12
15
24
Output
Current
max (A)
3
3
1.25
1
0.63
Maximum
Capacitive
Load
(µF)
4700
2200
1000
680
470
Efficiency
(%)
115
230
VAC
VAC
74
75
81
81
83
74
76
82
83
83
Models
Dual output
Model
AMES15-5DMAZ
AMES15-12DMAZ
AMES15-15DMAZ
90-264/47-440
90-264/47-440
90-264/47-440
130-370
130-370
130-370
Max
Output
wattage
Output
Voltage
(V)
(W)
15
15
15
±5
±12
±15
Output
Current
max (A)
±1.5
±0.63
±0.5
Maximum
Capacitive
Load
(µF)
±1000
±470
±330
Efficiency
(%)
115
230
VAC
VAC
78
81
82
79
82
83
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External Fuse
Input Dissipation
Under Voltage Protection
Conditions
Typical
115VAC
230VAC
115 VAC
230 VAC
115 VAC
264 VAC
(recommend)slow blow type
(110/230Vac)
Maximum
Units
350
180
10
20
0.1
0.2
mA
mA
A
A
mA
mA
A
W
VAC
Maximum
Units
2
൑0.2
85
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Cross regulation (dual output)
Transient Recovery Time
Transient Recovery Deviation
Ripple & Noise*
Hold-up time
Conditions
Typical
LL-HL
0-100%
25% load - 1st out, 100% load – 2nd out
25% load step
3.3/5V models
12/15V models
24V models
min
±2
±1
±1
±5
300
±2
75
100
150
20
%
%
%
%
µs
% of Vout
mVp-p
ms
* Ripple and Noise are measured at 20MHz bandwidth by using 0.1μF (M/C) and 47μF (E/C) parallel capacitor.
www.aimtec.com
F 052e R7.R
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMES15-MAZ
15 Watt | AC-DC / DC-DC Converter
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Isolation resistance
Typical
60 sec
Rated
Units
4000
VAC
MΩ
Maximum
Units
>1000
General Specifications
Parameters
Conditions
Switching frequency
Protection class
Start up time
Over load protection
Over voltage protection
Short circuit protection
Case material
Operating temperature
Storage temperature
Max Case temperature
Temperature coefficient
Cooling
Humidity
Weight
Dimensions (L x W x H)
Foldback
With derating over 55 oC (10CFM)
MTBF
Typical
132
Class II
350
>130
Zener diode clamp
Auto recovery
Metal
-40 to +80
-50 to +100
KHz
mS
%
oC
oC
100
oC
±0.02
Free air convection
% / oC
95
100
3.62 x 2.56 x 0.94 inches
92.0 x 65.0 x 24.0 mm
> 400,000hrs (MIL-HDBK -217F, t=+25oC)
> 100,000hrs (MIL-HDBK -217F, t=at highest operating temperature)
% RH
g
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Parameters
Shock
Vibrations
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety & EMC Specifications
Parameters
Agency approvals
cULus, CE, CB
IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No.
601.1-M90
Information technology Equipment
EN 60950-1:2006+A11:2009
EMI - Conducted and radiated emission
EN55011, class B
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2 Level 3
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 2
Electrical Fast Transient/Burst Immunity
IEC 61000-4-4 Level 3
Surge Immunity
IEC 61000-4-5 Level 3
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8 Level 2
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Tel: +1 514 620 2722
Toll free: + 1 888 9 AIMTEC
(924 6832)
2 of 5
North America only
Medical Electrical Equipment
Standards
www.aimtec.com
F 052e R7.R
Series AMES15-MAZ
15 Watt | AC-DC / DC-DC Converter
Derating
A
A
B
100
Free Air
Convection
40 º C
80
B
60
40
10 CFM
55 º C
Safe Operating Area
20
0
- 40 - 20
0
20
40
60
80
85
100
Ambient Temperature º C
Pin Out Specifications
Pin
Single
Dual
1
2
3
4
5
AC Input (N)
AC Input (L)
-V Output
No Connection
+V Output
AC Input (N)
AC Input (L)
-V Output
Common
+V Output
www.aimtec.com
F 052e R7.R
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMES15-MAZ
15 Watt | AC-DC / DC-DC Converter
24
(0.94)
Dimensions
PCB Mounting
Screw
PCB Mounting
Screw
Side View
PCB
Mylar Film
Bracket
Mountin
g Screw
PCB
Mylar Film
2.6 mm Max
Customer Chassis
www.aimtec.com
F 052e R7.R
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMES15-MAZ
15 Watt | AC-DC / DC-DC Converter
Optional DIN Rail Bracket
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for
release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications
which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at
www.aimtec.com.
www.aimtec.com
F 052e R7.R
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages