Vishay MSS2P2 Surface mount schottky barrier rectifier Datasheet

New Product
MSS2P2 & MSS2P3
Vishay General Semiconductor
Surface Mount Schottky Barrier Rectifiers
FEATURES
• Very low profile - typical height of 0.68 mm
eSMP TM Series
• Ideal for automated placement
• Low forward voltage drop, low power
losses
• High efficiency
Top View
Bottom View
MicroSMP
• Meets MSL level 1, per J-STD-020, LF maximum
peak of 260 °C
• Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
• Halogen-free
PRIMARY CHARACTERISTICS
IF(AV)
2.0 A
VRRM
20 V, 30 V
IFSM
30 A
VF at IF = 2.0 A
0.47 V
TJ max.
150 °C
MECHANICAL DATA
Case: MicroSMP
Molding compound meets UL 94V-0 flammability
rating.
Base P/N-E3 - RoHS compliant, commercial grade
Base P/N-M3 - halogen-free and RoHS compliant,
commercial grade
TYPICAL APPLICATIONS
For use in low voltage high frequency inverters,
freewheeling, dc-to-dc converters, and polarity
protection applications.
Terminals: Matte tin plated leads, solderable per
J-STD-002 and JESD22-B102
E3 and M3 suffix meets JESD 201 class 1A whisker
test
Polarity: Color band denotes the cathode end
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
MSS2P2
MSS2P3
22
23
Maximum repetitive peak reverse voltage
VRRM
20
30
Maximum average forward rectified current (Fig. 1)
IF(AV)
2.0
A
Peak forward surge current 8.3 ms single half sine-wave
superimposed on rated load
IFSM
30
A
TJ, TSTG
- 55 to + 150
°C
Device marking code
Operating junction and storage temperature range
Document Number: 89054
Revision: 04-Aug-08
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
UNIT
V
www.vishay.com
1
New Product
MSS2P2 & MSS2P3
Vishay General Semiconductor
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
TEST CONDITIONS
IF = 1.0 A
IF = 2.0 A
Maximum instantaneous
forward voltage (1)
SYMBOL
TYP.
MAX.
0.44
0.52
0.60
0.36
0.47
0.55
IR
15
6.0
250
20
µA
mA
CJ
65
-
pF
MSS2P3
UNIT
TA = 25 °C
V
VF
IF = 1.0 A
IF = 2.0 A
TA = 125 °C
Maximum reverse current (2)
rated VR
TA = 25 °C
TA = 125 °C
Typical junction capacitance
4.0 V, 1 MHz
UNIT
Notes:
(1) Pulse test: 300 µs pulse width, 1 % duty cycle
(2) Pulse test: Pulse width ≤ 40 ms
THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
MSS2P2
105
15
20
RθJA
RθJL
RθJC
Typical thermal resistance (1)
°C/W
Note:
(1) Thermal resistance from junction to ambient and junction to lead mounted on P.C.B. with 6.0 x 6.0 mm copper pad areas. RθJL is measured
at the terminal of cathode band. RθJC is measured at the top center of the body
ORDERING INFORMATION (Example)
PREFERRED P/N
UNIT WEIGHT (g)
PREFERRED PACKAGE CODE
BASE QUANTITY
DELIVERY MODE
MSS2P3-E3/89A
0.006
89A
4500
7" diameter plastic tape and reel
MSS2P3-M3/89A
0.006
89A
4500
7" diameter plastic tape and reel
RATINGS AND CHARACTERISTICS CURVES
(TA = 25 °C unless otherwise noted)
1.4
D = 0.3
D = 0.5
D = 0.8
1.2
2.0
Average Power Loss (W)
Average Forward Rectified Current (A)
2.4
1.6
1.2
0.8
TL Measured
at the Cathode Band Terminal
0.4
D = 0.2
1.0
D = 0.1
D = 1.0
0.8
0.6
T
0.4
0.2
D = tp/T
tp
1.6
2.0
0
0
80
90
100
110
120
130
140
150
0
0.4
0.8
1.2
2.4
Lead Temperature (°C)
Average Forward Current (A)
Figure 1. Forward Current Derating Curve
Figure 2. Forward Power Loss Characteristics
www.vishay.com
2
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
Document Number: 89054
Revision: 04-Aug-08
New Product
MSS2P2 & MSS2P3
Vishay General Semiconductor
1000
TJ = 150 °C
Junction Capacitance (pF)
Instantaneous Forward Current (A)
10
TJ = 125 °C
1
TJ = 25 °C
0.1
0.01
10
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.1
1
10
100
Instantaneous Forward Voltage (V)
Reverse Voltage (V)
Figure 3. Typical Instantaneous Forward Characteristics
Figure 5. Typical Junction Capacitance
1000
Transient Thermal Impedance (°C/W)
100
Instantaneous Reverse Current (mA)
100
TJ = 150 °C
10
TJ = 125 °C
1
0.1
0.01
TJ = 25 °C
0.001
10
20
30
40
50
60
70
80
90
Junction to Ambient
100
10
1
0.01
100
0.1
1
10
100
1000
Percent of Rated Peak Reverse Voltage (%)
t - Pulse Duration (s)
Figure 4. Typical Reverse Characteristics
Figure 6. Typical Transient Thermal Impedance
PACKAGE OUTLINE DIMENSIONS in inches (millimeters)
MicroSMP
0.059 (1.50)
0.043 (1.10)
Cathode Band
0.055 (1.40)
0.047 (1.20)
0.030 (0.75)
0.022 (0.55)
0.039 (0.98)
0.031 (0.78)
0.091 (2.30)
0.083 (2.10)
0.106 (2.70)
0.091 (2.30)
0.030 (0.75)
0.022 (0.55)
Mounting Pad Layout
0.079
(2.00)
0.029 (0.73)
0.025 (0.63)
0.043
(1.10)
0.011 (0.27)
0.005 (0.12)
Document Number: 89054
Revision: 04-Aug-08
0.032
(0.80)
0.032
(0.80)
0.020
(0.50)
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
3
Legal Disclaimer Notice
Vishay
Disclaimer
All product specifications and data are subject to change without notice.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein
or in any other disclosure relating to any product.
Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any
information provided herein to the maximum extent permitted by law. The product specifications do not expand or
otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed
therein, which apply to these products.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Vishay.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless
otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such
applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting
from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding
products designed for such applications.
Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 18-Jul-08