MINI BBP-30+ Bandpass filter Datasheet

Coaxial
Bandpass Filter
50Ω Elliptic Response
BBP-30+
27 to 33 MHz
Features
Maximum Ratings
Operating Temperature
-55°C to 100°C
Storage Temperature -55°C to 100°C
RF Power Input
0.5W max.
• low insertion loss, 1.5 dB max.
• good selectivity, 1.76 typ. 20 dB/3dB BW ratio
• rugged shielded case
CASE STYLE: FF55
Connectors Model
BNC
BBP-30+
Permanent damage may occur if any of these limits are exceeded.
Applications
• high rejection applications
• image rejection
• IF signal processing
+RoHS Compliant
The +Suffix identifies RoHS Compliance. See our web site
for RoHS Compliance methodologies and qualifications
Bandpass Filter Electrical Specifications­
CENTER
FREQ.
(MHz)
PASSBAND
(MHz)
30
Outline Drawing
3dB
BANDWIDTH
(MHz)
STOPBANDS
VSWR
(:1)
I.L. 1.5 dB
Max.
Typ.
(I. loss > 20 dB)
at MHz
(I. loss > 35 dB)
at MHz
Passband
Max.
Stopband
Typ.
27-33
25-35
22 &40
3.2 & 99-1000
1.7
16
AT T E NUAT ION, dB
typical frequency response
electrical schematic
3.00 fo
35.0
.60 fo
20.0
.34 fo
3.0
1.5
.2 fo
F R E QUE NC Y
Typical Performance Data
Outline Dimensions (
inch
mm
Frequency
(MHz)
)
1.0
1.4
1.9
2.3
2.8
3.2
4.0
16.0
22.0
23.0
23.7
24.3
25.0
27.0
29.3
30.5
32.8
35.0
36.0
37.3
38.7
40.0
50.0
82.7
99.0
190.0
392.5
595.0
797.5
1000.0
B
D
wt
.54
2.59 grams
13.72 65.79
40.0
INSERTION LOSS
25
80
60
40
20
0
1
10
100
FREQUENCY(MHz)
1000
at RF level of 0 dBm
x
σ
81.68
73.69
70.39
67.50
65.09
61.70
58.09
30.42
32.26
26.30
15.68
8.44
3.86
1.28
1.02
1.02
1.16
2.37
4.69
11.24
21.64
38.75
26.83
39.42
43.92
65.36
80.00
59.40
50.83
43.35
9.6
2.1
1.8
1.2
0.9
1.3
0.6
0.6
2.3
1.7
1.1
1.0
0.6
0.1
0.1
0.1
0.1
0.3
0.5
0.9
1.2
2.0
0.5
0.4
0.6
2.3
3.9
2.2
1.8
2.3
Frequency
(MHz)
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.4
0.6
0.8
1.2
2.5
6.3
20.8
21.6
20.0
18.6
8.8
4.5
1.7
0.9
0.7
0.3
0.3
0.3
0.3
0.4
0.4
0.6
0.8
RETURN LOSS
125
20
15
10
5
Group Delay
(nsec)
2.8
3.2
3.3
9.6
15.8
22.0
23.2
23.6
24.4
24.8
26.2
27.1
28.0
28.5
29.5
30.0
31.1
31.6
32.2
32.7
33.9
35.1
36.3
37.6
38.9
40.3
41.0
59.9
80.4
97.2
GROUP DELAY (nsec)
at RF level of 0 dBm
RETURN LOSS (dB)
INSERTION LOSS (dB)
100
Return Loss
(dB)
Insertion Loss
(dB)
_
at RF level of 0 dBm
30.059
21.884
12.226
7.216
11.923
89.768
56.479
40.798
22.806
103.619
115.164
99.025
78.962
72.223
64.660
62.760
61.836
62.724
64.652
67.765
76.095
80.917
75.838
9.558
16.978
34.601
41.413
3.448
1.230
0.971
GROUP DELAY
100
75
50
25
0
0
1
10
100
FREQUENCY(MHz)
1000
0
20
40
60
FREQUENCY (MHz)
80
100
Notes
A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.
B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions.
C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled
to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp
Mini-Circuits
®
www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 [email protected]
REV. C
M151107
BBP-30+
150601
Similar pages