Wall MRW10-24S24 10 watts dc/dc converter single and dual output Datasheet

MRW10 SERIES
10 Watts
DC/DC Converter
Single and Dual Output
Rev B
FEATURES
• Ultra Wide Input Range
• I/O Isolation 3000VAC with
Reinforced Insulation
• No Minimum Load Requirement
• Remote On/Off, Output Voltage
Trim
• RoHS & REACH Compliant
• Over Load, Over Voltage, and Short Circuit
Protection
• Railway Standard
• UL/cUL/IEC/EN 62368-1 (60950-1) Safety
Approval & CE Marking
DESCRIPTION
Size: 1in x 2in x 0.43in (25.4mm x 50.8mm x 11mm)
The MRW10 series of DC/DC converters offers up to 10 watts of output power in a
compact, industrial standard package. This series consists of single and dual output
models with ultra-wide input voltage range. Each model in this series has high
efficiency, no minimum load requirement, as well as over load, over voltage, and short
circuit protection. This series has UL/cUL/IEC/EN 62368-1 (60950-1) safety approvals
and CE markings.
MODEL SELECTION TABLE
Single Output Models
Model Number(1)
MRW10-24S05
MRW10-24S12
MRW10-24S15
MRW10-24S24
MRW10-48S05
MRW10-48S12
MRW10-48S15
MRW10-48S24
MRW10-110S05
MRW10-110S12
MRW10-110S15
MRW10-110S24
Input Voltage
Range
24VDC
(9~36VDC)
48VDC
(18~75VDC)
110VDC
(40~160VDC)
Output
Voltage
5VDC
12VDC
15VDC
24VDC
5VDC
12VDC
15VDC
24VDC
5VDC
12VDC
15VDC
24VDC
Input Current
Max. Output
Current
No Load Max. Load
2000mA
496mA
835mA
485mA
25mA
670mA
481mA
417mA
474mA
2000mA
245mA
835mA
240mA
15mA
670mA
241mA
417mA
242mA
2000mA
111mA
835mA
107mA
10mA
670mA
107mA
417mA
107mA
Over Voltage
Protection
Maximum
Capacitive Load
Efficiency
6.2VDC
15VDC
18VDC
30VDC
6.2VDC
15VDC
18VDC
30VDC
6.2VDC
15VDC
18VDC
30VDC
2200µF
330µF
220µF
100µF
2200µF
330µF
220µF
100µF
2200µF
330µF
220µF
100µF
84%
86%
87%
88%
85%
87%
87%
86%
82%
85%
85%
85%
Over Voltage
Protection
Maximum
Capacitive Load
Efficiency
±15VDC
±18VDC
±15VDC
±18VDC
±15VDC
±18VDC
150#µF
100#µF
150#µF
100#µF
150#µF
100#µF
86%
87%
89%
88%
86%
86%
Output
Power
10W
10W
10W
MODEL SELECTION TABLE
Single Output Models
Model Number(1)
Input Voltage
Range
Output
Voltage
MRW10-24D12
MRW10-24D15
MRW10-48D12
MRW10-48D15
MRW10-110D12
MRW10-110D15
24VDC
(9~36VDC)
±12VDC
±15VDC
±12VDC
±15VDC
±12VDC
±15VDC
1/9/2018
48VDC
(18~75VDC)
110VDC
(40~160VDC)
Input Current
Max. Output
Current
No Load Max. Load
±417mA
485mA
25mA
±335mA
481mA
±417mA
234mA
15mA
±335mA
238mA
±417mA
106mA
10mA
±335mA
106mA
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Output
Power
10W
10W
10W
Page 1 of 10
MRW10 SERIES
10 Watts
DC/DC Converter
Single and Dual Output
Rev B
SPECIFICATIONS
All specifications are based on 25°C, Resistive Load, Nominal Input Voltage, and Rated Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
9
18
40
-0.7
-0.7
-0.7
24
48
110
36
75
160
50
100
170
9
18
40
Unit
INPUT SPECIFICATIONS
Input Voltage Range
Input Surge Voltage (100ms. Max)
Start-Up Threshold Voltage
Under Voltage Shutdown
24V Input Models
48V Input Models
110V Input Models
24V Input Models
48V Input Models
110V Input Models
24V Input Models
48V Input Models
110V Input Models
24V Input Models
48V Input Models
110V Input Models
Input Filter
OUTPUT SPECIFICATIONS
Output Voltage
Voltage Accuracy
Line Regulation
Vin=Min. to Max. @ Full Load
Load Regulation
Io=0% to 100%
Voltage Balance
Output Power
Output Current
Minimum Load
Maximum Capacitive Load
Dual Outputs, Balanced Loads
7.5
16
37
Internal Pi Type
Case Material
Base Material
Pin Material
Potting Material
Insulated Frame Material
RFI
1/9/2018
VDC
VDC
VDC
See Table
±1.0
±0.2
±0.5
±1.0
±2.0
Single Output
Dual Output
5V Outputs Models
Measured with 10µF/25V MLCC
Ripple & Noise (20MHz bandwidth) 12V, 15V, ±12V, ±15V Output Models
24V Output Models
Measured with 4.7µF/50V MLCC
Transient Recovery Time(2)
25% Load Step Change
Transient Response Deviation
25% Load Step Change
Start-Up Time (Power On)
All Models
Temperature Coefficient
Trim Up/Down Range
% of Nominal Output Voltage
REMOTE ON/OFF CONTROL
Converter On
Converter Off
Control Input Current (On)
Vctrl=5.0V
Control Input Current (Off)
Vctrl=0V
Control Common
Standby Input Current
Nominal Vin
PROTECTION
Short Circuit Protection
Automatic Recovery
Over Load Protection
Hiccup Mode
Over Voltage Protection
GENERAL SPECIFICATIONS
Efficiency
Switching Frequency
Isolation Voltage
Reinforced Insulation, Rated for 60 seconds
Isolation Resistance
500VDC
Isolation Capacitance
100KHz, 1V
PHYSICAL SPECIFICATIONS
Weight
Dimensions (L x W x H)
VDC
%Vnom
%
%
%
See Table
See Table
No Minimum Load Requirement
See Table
50
100
mVp-p
150
300
µsec
±3
±5
%
50
mS
±0.02
%/ºC
±10
%
3.5V~12V or Open Circuit
0V~1.2V or Short Circuit
0.5
mA
-0.5
mA
Referenced to Negative Input
2.5
mA
Hiccup Mode 0.3Hz typ.
150
See Table
See Table
280
3000
1000
1500
%
kHz
VACrms
MΩ
pF
1.43oz (40.5g)
1in x 2in x 0.43in
(25.4mm x 50.8mm x 11mm)
Red Copper, Powder Coating
FR4 PCB (Flammability to UL 94V-0 Rated)
Tinned Copper
Epoxy (UL94-V0)
Non-Conductive Black Plastic (Flammability
to UL 94V-0 Rated)
Six Sided Shielded, Metal Case
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 2 of 10
MRW10 SERIES
10 Watts
DC/DC Converter
Single and Dual Output
Rev B
SPECIFICATIONS
All specifications are based on 25°C, Resistive Load, Nominal Input Voltage, and Rated Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
Unit
ENVIRONMENTAL SPECIFICATIONS
Min
Natural Convection,
Nominal Vin, Load
100% Inom.
Operating Temperature
MRW10-48D12
MRW10-24S24, 48D15
MRW10-24S15, 48S12, 48S15, 24D15
MRW10-24S12, 48S24, 24D12, 110D12, 110D15
MRW10-48S05, 110S12, 110S15, 110S24
MRW10-24S05
MRW10-110S05
Storage Temperature
Thermal Impedance
Humidity
Case Temperature
Lead Temperature
Cooling Test
Dry Heat
Damp Heat
Shock and Vibration Test
MTBF (Calculated)
SAFETY CHARACTERISTICS
Safety Approvals
General
EMI
EMS
Natural Convection without Heatsink
Natural Convection with Heatsink
100LFM Convection without Heatsink
100LFM Convection with Heatsink
200LFM Convection without Heatsink
200LFM Convection with Heatsink
400LFM Convection without Heatsink
400LFM Convection with Heatsink
Non-Condensing
1.5mm from case for 10Sec.
MIL-HDBK-217F@25ºC Full Load, Ground Benign
-40
-40
-40
-40
-40
-40
-40
-50
12.1
9.8
9.2
5.4
7.8
4.5
5.2
3.0
Max.
Without
With
Heatsink Heatsink
90
93
88
92
87
90
85
89
84
88
82
86
78
83
+125
ºC
ºC
ºC/W
95
%RH
+105
ºC
260
ºC
Compliance to IEC/EN60068-2-1
Compliance to IEC/EN60068-2-2
Compliance to IEC/EN60068-2-30
Compliance to IEC/EN 61373
2,845,385
Hours
UL/cUL 60950-1 Recognition (UL Certificate)
IEC/EN 60950-1 (CB Report)
EN 50155
IEC 60571
UL/cUL 62368-1 recognition (UL Certificate)
IEC/EN 62368-1 (CB-Report)
EN 50121-3-2 Railway Applications
Conduction
EN55032, EN55022, FCC Part 15
EN55024
ESD
Radiated Immunity
Fast Transient(6)
Surge(6)
Conducted Immunity
PFMF
Unit
EN61000-4-2 Air ±8kV, Contact ±6kV
EN61000-4-3 10V/m
EN61000-4-4 ±2kV
EN61000-4-5 ±2kV
EN61000-4-6 10Vrms
EN61000-4-8 3A/M
Class A
A
A
A
A
A
A
NOTES
1. Two pinning types are available. Add “A” to model number to indicate A pinning (See mechanical drawings for more detail)
Heat sink is also available. Add “HS” to model number to indicate Heatsink.
2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3. It is recommended to protect the converter by a slow blow fuse in the input supply line.
4. Other input and output voltages may be available, please contact factory.
5. Natural convection is about 20LFM but is not equal to still air (0 LFM).
6. To meet EN61000-4-4 & EN61000-4-5 an external capacitor across the pins is required.
Suggested capacitors:
24V In: CHEMI-CON KY Series 390µF/63V
48V In: CHEMI-CON KY Series 330µF/100V
110V In: CHEMI-CON KXG Series 220µF/250V.
*Due to advances in technology, specifications subject to change without notice.
1/9/2018
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 3 of 10
Rev B
MRW10 SERIES
10 Watts
DC/DC Converter
Single and Dual Output
DERATING CURVES
1/9/2018
MRW10-48D12 Derating Curve without Heatsink
MRW10-48D12 Derating Curve with Heatsink
MRW10-24S24, 48D15
Derating Curve without Heatsink
MRW10-24S24, 48D15
Derating Curve with Heatsink
MRW10-24S15, 48S12, 48S15, 24D15
Derating Curve without Heatsink
MRW10-24S15, 48S12, 48S15, 24D15
Derating Curve with Heatsink
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 4 of 10
Rev B
1/9/2018
MRW10 SERIES
10 Watts
DC/DC Converter
Single and Dual Output
MRW10-24S12, 48S24, 24D12, 110D12, 110D15
Derating Curve without Heatsink
DHZ110-24S12, 48S24, 24D12, 110D12, 110D15
Derating Curve with Heatsink
MRW10-48S05, 110S12, 110S15, 110S24
Derating Curve without Heatsink
MRW10-48S05, 110S12, 110S15, 110S24
Derating Curve with Heatsink
MRW10-24S05 Derating Curve without Heatsink
MRW10-24S05 Derating Curve with Heatsink
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 5 of 10
MRW10 SERIES
10 Watts
DC/DC Converter
Single and Dual Output
Rev B
MRW10-110S05 Derating Curve without Heatsink
MRW10-110S05 Derating Curve with Heatsink
MECHANICAL DRAWINGS
Standard
Pin
1
2
3
4
5
6
PIN CONNECTIONS
Single
Dual
+Vin
+Vin
-Vin
-Vin
Remote On/Off
Remote On/Off
+Vout
+Vout
Trim
Common
-Vout
-Vout
All dimensions in mm (inches)
Tolerance: X.X±0.75 (X.XX±0.03)
X.XX±0.25 (X.XXX±0.01)
Pin Diameter Ø1.0±0.05 (0.04±0.002)
1/9/2018
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 6 of 10
MRW10 SERIES
10 Watts
DC/DC Converter
Single and Dual Output
Rev B
“A” Pinning
PIN
1
2
3
4
5
6
PIN CONNECTIONS
Single
Dual
+Vin
+Vin
-Vin
-Vin
Remote On/Off
Remote On/Off
+Vout
+Vout
-Vout
Common
Trim
-Vout
All dimensions in mm (inches)
Tolerance: X.X±0.75 (X.XX±0.03)
X.XX±0.25 (X.XXX±0.01)
Pin Diameter Ø1.0 ±0.05 (0.04±0.002)
HEATSINK OPTIONS
Standard
“A” Pinning
Heatsink Material: Aluminum
Finish: Black Anodized Coating
Weight: 9g
Advantages of Heatsink: Improve heat dissipation and increase stability and reliability of converter at high operating temperature.
1/9/2018
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 7 of 10
MRW10 SERIES
10 Watts
DC/DC Converter
Single and Dual Output
Rev B
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by using the method shown below.
MRW10-XXS05 Trim Table
Trim Down
Vout=
Rd=
1
Vox0.99
137.88
2
Vox0.98
61.93
3
Vox0.97
36.61
4
Vox0.96
23.95
5
Vox0.95
16.35
6
Vox0.94
11.29
7
Vox0.93
7.67
8
Vox0.92
4.96
9
Vox0.91
2.85
10
Vox0.90
1.16
%
Volts
KOhms
Trim Up
Vout=
Ru=
1
Vox1.01
108.09
2
Vox1.02
48.39
3
Vox1.03
28.49
4
Vox1.04
18.54
5
Vox1.05
12.56
6
Vox1.06
8.58
7
Vox1.07
5.74
8
Vox1.08
3.61
9
Vox1.09
1.95
10
Vox1.10
0.62
%
Volts
KOhms
MRW10-XXS12 Trim Table
Trim Down
Vout=
Rd=
1
Vox0.99
419.81
2
Vox0.98
187.68
3
Vox0.97
110.30
4
Vox0.96
71.61
5
Vox0.95
48.40
6
Vox0.94
32.93
7
Vox0.93
21.87
8
Vox0.92
13.58
9
Vox0.91
7.13
10
Vox0.90
1.98
%
Volts
KOhms
Trim Up
Vout=
Ru=
1
Vox1.01
344.74
2
Vox1.02
154.37
3
Vox1.03
90.92
4
Vox1.04
59.19
5
Vox1.05
40.15
6
Vox1.06
27.46
7
Vox1.07
18.39
8
Vox1.08
11.59
9
Vox1.09
6.31
10
Vox1.10
2.07
%
Volts
KOhms
MRW10-XXS15
Trim Down
Vout=
Rd=
1
Vox0.99
602.92
2
Vox0.98
269.91
3
Vox0.97
158.91
4
Vox0.96
103.41
5
Vox0.95
70.10
6
Vox0.94
47.90
7
Vox0.93
32.05
8
Vox0.92
20.15
9
Vox0.91
10.90
10
Vox0.90
3.50
%
Volts
KOhms
Trim Up
Vout=
Ru=
1
Vox1.01
482.88
2
Vox1.02
215.89
3
Vox1.03
126.89
4
Vox1.04
82.40
5
Vox1.05
55.70
6
Vox1.06
37.90
7
Vox1.07
25.18
8
Vox1.08
15.65
9
Vox1.09
8.23
10
Vox1.10
2.30
%
Volts
KOhms
MRW10-XXS24
Trim Down
Vout=
Rd=
1
Vox0.99
598.97
2
Vox0.98
267.93
3
Vox0.97
157.59
4
Vox0.96
102.42
5
Vox0.95
69.31
6
Vox0.94
47.25
7
Vox0.93
31.48
8
Vox0.92
19.66
9
Vox0.91
10.46
10
Vox0.90
3.11
%
Volts
KOhms
Trim Up
Vout=
Ru=
1
Vox1.01
486.83
2
Vox1.02
217.87
3
Vox1.03
128.21
4
Vox1.04
83.38
5
Vox1.05
56.49
6
Vox1.06
38.56
7
Vox1.07
25.75
8
Vox1.08
16.14
9
Vox1.09
8.67
10
Vox1.10
2.69
%
Volts
KOhms
TEST SETUP
Peak-to-Peak Output Noise Measurement Test
Use a 1µF ceramic capacitor and a 10µF tantalum capacitor. Scope measurement should be made by using a BNC socket,
measurement bandwidth is 0-20MHz. Position the load between 50mm and 75mm from the DC/DC converter.
1/9/2018
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 8 of 10
Rev B
MRW10 SERIES
10 Watts
DC/DC Converter
Single and Dual Output
TECHNICAL NOTES
Remote On/Off
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn
the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the –Vin terminal.
The switch can be an open collector or equivalent. A logic low is 0V to 1.2V. A logic high is 3.5V to 12V. The maximum sink current at
the on/off terminal (Pin 3) during a logic low is -100µA.
Overload Protection
To protect hiccup mode protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and
can endure overload for an unlimited duration.
Overvoltage Protection
The output overvoltage clamp consists of control circuitry, which is independent of the primary regulation loop that monitors the voltage
on the output terminals. The control loop of the clamp has a higher voltage set point than the primary loop. This provides redundant
voltage control that reduces the risk of output overvoltage. The OVP level can be found in the output data.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the
stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to
use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is
recommended to use a good quality low Equivalent Series Resistance (ESR <1.0Ω at 100KHz) capacitor of 4.7µF for the 24V input
devices, a 2.2µF for the 48V devices and a 1µF for the 110V devices.
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To
reduce output ripple, it is recommended to use 4.7µF capacitors at the output.
Maximum Capacitive Load
The MRW10 series has limitation of maximum connected capacitance at the output. The power module may be operated in current
limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module, and board spacing.
To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept
below 105ºC. The derating curves are determined from measurements obtained in a test setup.
1/9/2018
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 9 of 10
Rev B
MRW10 SERIES
10 Watts
DC/DC Converter
Single and Dual Output
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely
with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide
ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your
future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
1/9/2018
(603)778-2300
(888)597-9255
(603)778-9797
[email protected]
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 10 of 10