ETC2 E9225L Dc axial fan Datasheet

HIGH PERFORMANCE
0.98 ±0.02
(25 ±0.5)
3.62 ±0.02
(92 ±0.5)
3.25 ±0.01
(82.5 ±0.3)
0.16
(4)
.32
0.16
(4)
STATIC PRESSURE - IN. OF WATER
DC AXIAL FANS
E9225 series
X
.28
E
.24
H
.20
M
L
.16
S
.12
.08
.04
10
0
20
4x Ø 0.18
(Ø 4.5)
30
40
50
60
AIR FLOW (CFM)
(92 x 92 x 25 mm)
3.62 x 3.62 x 0.98 inches
Construction:
UL94V-0 PBT impeller & frame
Bearing option: ball bearing
Rated
Voltage
Current
mA
Speed
Air Volume
Max. Static
Sound Weight
Pressure (H2 0) Noise
V
5
12
24
48
RPM
MM
INCH
dbA
g
Connection:
AWG 24, 1007 lead wires
E9225S
5/12/24
270
98
60
-
2,000
0.82
29
2.25
0.09
24
111
Frame:
flanged
E9225L
5/12/24
400
150
85
-
2,400
0.99
35
3.25
0.13
27
111
Protection:
thermal
Options:
tachometer output or locked rotor
alarm signal; PWM speed control
w w w.mechatronic s.com
12.15.14
Model No.
M³/Min. CFM
E9225M
5/12/24
560
235
125
-
2,800
1.24
44
4.75
0.19
32
111
E9225H
12/24/48
-
360
168
65
3,200
1.44
51
6.00
0.24
36
111
E9225E
12/24/48
-
498
255
85
3,600
1.58
56
7.00
0.28
39
111
E9225X
12/24/48
-
550
300
130
4,000
1.70
60
8.00
0.32
43
111