AIMTEC AMEOF3-12SJZ Continuous short circuit protection Datasheet

Series AMEOF3-JZ
O
3 Watt | AC-DC Converter
Picture Coming Soon
FEATURES:
•
•
•
•
Input: 85-264VAC, 47-440Hz or 70-400VDC
Operating temperature -40°C to +85°C
Low power consumption ≤ 0.5W
Continuous short circuit protection
•
•
•
•
I/O Isolation 3000VAC
Ultra slim open frame SIP
Over current protection
Class II power supply
Models
Single output
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Full power
temperature
range
(ºC)
Output
Voltage
(V)
Output
Current max
(mA)
Maximum
capacitive
load
(µF)
Efficiency
(%)
AMEOF3-3.3SJZ
AMEOF3-5SJZ
AMEOF3-9SJZ
AMEOF3-12SJZ
AMEOF3-15SJZ
AMEOF3-24SJZ
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
70-400
70-400
70-400
70-400
70-400
70-400
-20 to +55
-20 to +55
-20 to +55
-20 to +55
-20 to +55
-20 to +55
3.3
5
9
12
15
24
500
500
333
250
200
125
470
470
150
100
100
100
63
68
75
77
78
80
AMEOF3-3.3SLJZ
AMEOF3-5SLJZ
AMEOF3-9SLJZ
AMEOF3-12SLJZ
AMEOF3-15SLJZ
AMEOF3-24SLJZ
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
70-400
70-400
70-400
70-400
70-400
70-400
-20 to +55
-20 to +55
-20 to +55
-20 to +55
-20 to +55
-20 to +55
3.3
5
9
12
15
24
500
500
333
250
200
125
470
470
150
100
100
100
63
68
75
77
78
80
Model
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Current
Inrush current <2ms
External fuse
Input dissipation
Input filter
Conditions
Typical
115VAC
230VAC
115VAC
230VAC
Recommended slow blow type
No Load
Maximum
120
60
13
23
1
0.5
Recommended external π (Pi) filter
Units
mA
mA
A
A
A
W
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise
Minimum load current
Conditions
Typical
Full load, 3.3V output
Full load, others
Full load
10% - 100% load
20MHz Bandwidth
Maximum
Units
±8
±5
%
±1.5
±2.5
150
10
%
%
mV p-p
% of Max
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
www.aimtec.com
F 052e R0
Conditions
Typical
60 sec
>1000
Tel: +1 514 620 2722
1 of 4
Rated
Units
3000
VAC
MΩ
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEOF3-JZ
O
3 Watt | AC-DC Converter
General Specifications
Parameters
Conditions
Switching frequency
Over current protection
Short circuit protection
Short circuit restart
Operating temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Weight
Dimensions (L x W x H)
MTBF
Typical
Maximum
Units
60
≥110
Continuous
Auto-recovery
-40 to +85
-40 to +105
±0.15
Free air convection
KHz
% of I out
85
7
1.38 x 0.71 x 0.43 inches
35 x 18 x 11 mm
o
>300,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 C)
% RH
g
Auto-recovery
See derating curve
°C
°C
% / °C
Safety Specifications
Parameters
IEC/EN/UL60950-1 pending approval
EN 55022, Class A & B, with external filter circuits, as referenced
IEC 61000-4-2, Contact ±4KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A, with Class B external filter, as referenced
IEC 61000-4-4, ±2KV/±4KV, Criteria B, with Class A/B external filter referenced
IEC 61000-4-5, ±1KV/±2KV, Criteria B, with Class A/B external filter referenced
IEC 61000-4-6, 10Vrms, Criteria A, with Class B external filter, as referenced
IEC 61000-4-8, 10A/m, Criteria A, with Class B external filter, as referenced
IEC 61000-4-11, 0-70%, Criteria B, with Class B external filter, as referenced
Pin Out Specifications*
35.00
(1.38)
* Add capacitor between pin 5 & 7.
Application circuit below.
1
3
5
7
10
1.15
(0.05)
5.08
(0.20)
www.aimtec.com
F 052e R0
11.00
(0.43)
12
10.00
(0.39)
1.30
(0.05)
1.75
(0.07)
1
3
5
7
10
12
Dimensions
Single
AC N
AC L
+V sc
-V sc
-V Output
+V Output
18.00
(0.71)
Pin
0.50
(0.02)
Standards
Note:
Unit: mm (inch)
Pin diameter tolerance: ±0.10 (±0.004)
Case tolerance: ±0.50 (±0.02)
27.94
(1.10)
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEOF3-JZ
O
3 Watt | AC-DC Converter
L models
35.00
(1.38)
18.00
(0.71)
Top view
1
5
3
10
7
Note:
Unit: mm (inch)
Pin diameter tolerance: ±0.10 (±0.004)
Case tolerance: ±0.50 (±0.02)
12
1.30
(0.05)
Right view
11.00
(0.43)
Front view
5.08
(0.20)
27.94
(1.10)
6.00
(0.24)
1.60
(0.06)
0.80
(0.03)
0.40
(0.02)
Derating*
Free Air Convection at 25°C
Free Air Convection
100
80
Output Power (%)
Output Power (%)
100
Safe Operating Area
100% load 110-240VAC
Or 100-340VDC
60
40
20
60
Safe Operating Area
40
20
0
- 40
80
- 20
0
20
40
55
60
80
85
0
100
85
110
(70) (100)
Ambient Temperature º C
240
(340)
264
(400)
Input Voltage VAC (VDC)
*Power derating: -40 to -20 increase 1%/°C
55 to 85 decrease 0.67%/°C
www.aimtec.com
F 052e R0
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEOF3-JZ
O
3 Watt | AC-DC Converter
Recommended EMC class A external circuit:
AC L
FUSE
1A/250V
Single Output
L1
4.7mH
NTC
C1
10µF/450V
MOV
S14K350
12
3
+
L2
2.2µH
5
AC
+
DC
+Vout
C3 +
C2
TVS
C4
0.1µF/50V
7
AC N
1
10
- Vout
Pi filter
CY1
1nF/400VAC
Recommended EMC class B external circuit:
AC L
FUSE
1A/250V
LDM
0.33mH
LCM
3.5mH
CX
0.1µF/
275VAC
MOV
S14K350
AC N
CY2
1nF/
400VAC
CY3
1nF/
400VAC
Single Output
NTC
24 Vout
+Vout
5
C1
4.7µF/
450V
AC
+
DC
C2
C3 +
7
1
10
TVS
C4
0.1µF/50V
- Vout
Pi filter
GND
Model
3.3 Vout
5 Vout
9 Vout
12 & 15
Vout
12
3
+
L2
2.2µH
CY1
1nF/400VAC
C2
330 µF /
25V
150 µF /
35V
100 µF /
35V
C3
120 µF / 25V
TVS
7V
12V
68 µF / 35V
20V
30V
Note: For Safety compliance we recommend minimum
PCB trace distance of 3mm, minimum distance between
PCB traces of 6mm, primary to secondary circuit traces
distance between minimum of 6.4mm.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4 . All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R0
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages