TDK B39741B8612P810 Saw components saw duplexer Datasheet

SAW Components
SAW Duplexer
LTE Band 17
Series/type:
Ordering code:
B8612
B39741B8612P810
Date:
Version:
April 16, 2014
2.2
 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
SAW Components
B8612
SAW Duplexer
710.0 / 740.0 MHz
Preliminary data
Application
■ Low-loss SAW duplexer for mobile telephone
LTE Band 17 systems
High attenuation
High Isolation
Low amplitude ripple
Usable passband 12 MHz
Single-ended to balanced transformation in
Antenna-Rx path
■ Impedance transformation 50 Ω to 100 Ω in
Antenna-Rx path
■ Very small size and low height
■
■
■
■
■
0.3
0.35
1
0.7
Package size 1.8 * 1.4 mm2
Package height: maximum 0.475mm
RoHS compatible
Package for Surface Mount Technology (SMT)
Ni, Au-plated terminals
Electrostatic Sensitive Device (ESD)
Moisture Sensitivity Level 3
2
3
4
8
7
0.475 max.
■
■
■
■
■
■
■
6
5
0.25
0.25
Features
bottom view
side view
1.8
1.4
7
4
Pin configuration
3
1, 8
6
2, 4, 5, 7
Tx input
Rx output (balanced)
Antenna
To be grounded
Please read cautions and warnings and
important notes at the end of this document.
2
5
8
1
■
■
■
■
6
April 16, 2014
2
3
top view
SAW Components
B8612
SAW Duplexer
710.0 / 740.0 MHz
Preliminary data
Characteristics
Temperature range for specification:
TX terminating impedance:
ANT terminating impedance:
RX teminating impedance:
T = –20 ˚C to +85 ˚C
ZTx = 50 Ω
ZAnt = 50 Ω || 15 nH
ZRx = 100 Ω (balanced)
B8612
Characteristics Tx-Antenna
min.
Center frequency
fc
max.
-
typ.
@ 25 ˚C
710
-
1.4
2.2
dB
-
MHz
α
Maximum insertion attenuation
704.0 ... 716.0
MHz
Amplitude ripple (p-p)
704.0 ...
716.0
MHz
-
0.4
1.3
dB
Error Vector Magnitude
@ fCarrier 706.4 ...
712.0
-
0.9
3.0
%
-
1.2
3.5
%
∆α
...
713.6
MHz EVM1)
MHz EVM1)
Input VSWR (Tx port)
704.0 ...
716.0
MHz
-
1.4
2.0
Output VSWR (Ant Port)
704.0 ...
716.0
MHz
-
1.4
2.0
Third Harmonic at 2130MHz
-
-80
-
@ fCarrier 712.0
Harmonic Level CW tone at 710MHz 2)
1)
2)
Error Vector Magnitude (EVM) based on definition in 3GPP TS 25.141
Power level: +27dBm on Tx port
Please read cautions and warnings and
important notes at the end of this document.
3
April 16, 2014
dBm
SAW Components
B8612
SAW Duplexer
710.0 / 740.0 MHz
Preliminary data
Characteristics
Temperature range for specification:
TX terminating impedance:
ANT terminating impedance:
RX teminating impedance:
T = -20 ˚C to +85 ˚C
ZTx = 50 Ω
ZAnt = 50 Ω || 15 nH
ZRx = 100 Ω (balanced)
B8612
Characteristics Tx-Antenna
Absolute attenuation
10.0
692.0
722.0
728.0
734.0
746.0
768.0
869.0
1408.0
1565.0
1805.0
1930.0
2110.0
2155.0
2400.0
2816.0
min.
typ.
@ 25 ˚C
max.
30
2.5
2.5
20
45
35
35
35
40
43
45
45
48
48
50
45
43
7
10
29
55
44
42
46
46
48
51
53
55
55
61
55
-
α
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
692.0
698.0
728.0
734.0
746.0
768.0
805.0
894.0
1432.0
1607.0
1880.0
1990.0
2155.0
2170.0
2497.0
2864.0
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Please read cautions and warnings and
important notes at the end of this document.
4
April 16, 2014
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
SAW Components
B8612
SAW Duplexer
710.0 / 740.0 MHz
Preliminary data
Characteristics
Temperature range for specification:
TX terminating impedance:
ANT terminating impedance:
RX teminating impedance:
T = –20˚C to +85 ˚C
ZTx = 50 Ω
ZAnt = 50 Ω || 15nH
ZRx = 100 Ω (balanced)
B8612
Characteristics Antenna-Rx
Center frequency
fc
max.
-
740
-
-
1.6
2.3
dB
dB
MHz
...
746.0
MHz
...
746.0
MHz
-
0.3
1.0
...
746.0
MHz
-
1.3
2.0
...
746.0
MHz
-
1.3
2.0
746.0
MHz
30
34
-
dB
35
50
35
50
40
20
13
7
35
40
40
38
35
64
62
62
62
48
27
21
16
39
53
50
47
44
-
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
∆α
Amplitude ripple (p-p)
734.0
typ.
@ 25 ˚C
α
Maximum insertion attenuation
734.0
min.
Input VSWR (Ant port)
734.0
Output VSWR (Rx Port)
734.0
Common mode rejection ratio
734.0
...
α
Absolute attenuation
10.0
674.0
686.0
704.0
716.0
722.0
725.0
727.0
777.0
793.0
805.0
3300.0
4500.0
... 674.0
... 686.0
... 704.0
... 716.0
... 722.0
... 725.0
... 727.0
... 728.0
... 793.0
... 805.0
... 3300.0
... 4500.0
... 6000.0
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Please read cautions and warnings and
important notes at the end of this document.
5
April 16, 2014
SAW Components
B8612
SAW Duplexer
710.0 / 740.0 MHz
Preliminary data
Characteristics
Temperature range for specification:
TX terminating impedance:
ANT terminating impedance:
RX teminating impedance:
T = -20 ˚C to +85 ˚C
ZTx = 50 Ω
ZAnt = 50 Ω || 15nH
ZRx = 100 Ω (balanced)
B8612
Characteristics Tx-Rx
min.
typ.
@ 25 ˚C
max.
58
58
55
52
30
30
30
64
70
61
56
69
62
59
-
dB
dB
dB
dB
dB
dB
dB
52
57
-
dB
α
Differential mode isolation
704.0 ... 716.0
734.0 ... 738.0
738.0 ... 742.0
742.0 ... 746.0
1408.0 ... 1432.0
2112.0 ... 2148.0
2816.0 ... 2864.0
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Common mode isolation
704.0 ...
MHz
α
716.0
Maximum Ratings
Storage temperature range
DC voltage
ESD voltage
Input power at Tx Port
704.0 ...716.0 MHz
elsewhere
1)
Tstg
VDC
VESD
Pin
Pin
–40/+85
5
1001)
29
10
˚C
V
V
dBm
dBm
machine model, 1 pulse
}
continuous wave
55 ˚C, 5000h
According to JESD22-A115A (machine model), 1 negative and 1 positive pulses.
Please read cautions and warnings and
important notes at the end of this document.
6
April 16, 2014
SAW Components
B8612
SAW Duplexer
710.0 / 740.0 MHz
Preliminary data
Frequency Response TX-ANT Narrow Band
Frequency Response TX-ANT Bandwidth
Please read cautions and warnings and
important notes at the end of this document.
7
April 16, 2014
SAW Components
B8612
SAW Duplexer
710.0 / 740.0 MHz
Preliminary data
Frequency Response ANT-RX Narrow Band
Frequency Response ANT-RX Bandwidth
Please read cautions and warnings and
important notes at the end of this document.
8
April 16, 2014
SAW Components
B8612
SAW Duplexer
710.0 / 740.0 MHz
Preliminary data
Frequency Response ANT-TX Wide Band
Frequency Response ANT-RX Wide Band
Please read cautions and warnings and
important notes at the end of this document.
9
April 16, 2014
SAW Components
B8612
SAW Duplexer
710.0 / 740.0 MHz
Preliminary data
Frequency Response TX-RX : Differential mode isolation
Frequency Response TX-RX : Common mode isolation
Please read cautions and warnings and
important notes at the end of this document.
10
April 16, 2014
SAW Components
B8612
SAW Duplexer
710.0 / 740.0 MHz
Preliminary data
S11 VSWR (TX)
S22 VSWR (ANT)
S33 VSWR (RX)
Please read cautions and warnings and
important notes at the end of this document.
11
April 16, 2014
SAW Components
B8612
SAW Duplexer
710.0 / 740.0 MHz
Preliminary data
References
Type
B8612
Ordering code
B39741B8612P810
Marking and package
C61157-A8-A57
Packaging
F61074-V8259-Z000
Date codes
L_1126
S-parameters
B8612_NB.s4p
B8612_WB.s4p
Soldering profile
S_6001
RoHS compatible
Defined as compatible with the following documents:
"DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIAMENT
AND OF THE COUNCIL of 27 January 2003 on the restriction
of the use of certain hazardous substances in electrical and
electronic equipment. 2005/618/EC from April 18th, 2005,
amending Directive 2002/95/EC of the European Parliament
and of the Council for the purposes of establishing the maximum concentration values for certain hazardous substances in
electrical and electronic equipment."
Matching coils
See
http://www.tdk.co.jp/tefe02/coil.htm#aname1
http://www.tdk.co.jp/etvcl/index.htm
for a large variety of matching coils.
For further information please contact your local EPCOS sales office or visit our webpage at
www.epcos.com .
Published by EPCOS AG
Systems, Acoustics, Waves Business Group
P.O. Box 80 17 09, 81617 Munich, GERMANY
 EPCOS AG 2014. This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
Please read cautions and warnings and
important notes at the end of this document.
12
April 16, 2014
Important notes
The following applies to all products named in this publication:
1.
2.
3.
4.
5.
6.
7.
Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately
incumbent on the customer to check and decide whether an EPCOS product with the
properties described in the product specification is suitable for use in a particular customer
application.
We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained
by third parties in the event of malfunction or failure of an electronic component.
The warnings, cautions and product-specific notes must be observed.
In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be
available. The aforementioned does not apply in the case of individual agreements deviating
from the foregoing for customer-specific products.
Unless otherwise agreed in individual contracts, all orders are subject to the current
version of the “General Terms of Delivery for Products and Services in the Electrical
Industry” published by the German Electrical and Electronics Industry Association
(ZVEI).
The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CeraLink, CeraPlas, CSMP, CSSP,
CTVS, DeltaCap, DigiSiMic, DSSP, FilterCap, FormFit, MiniBlue, MiniCell, MKD, MKK, MLSC,
MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL,
SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP, ThermoFuse,
WindCap are trademarks registered or pending in Europe and in other countries. Further
information will be found on the Internet at www.epcos.com/trademarks.
13
April 16, 2014
Similar pages