P-DUKE DFEC60-24S15 Dc-dc converter Datasheet

DFEC60 SERIES
CHASSIS-MOUNT DC-DC CONVERTER
2:1 WIDE INPUT RANGE
UP TO 60 Watts
FEATURES
APPLICATIONS
• NO MINIMUM LOAD REQUIRED
• 1600VDC INPUT TO OUTPUT ISOLATION
• SCREW TERMINALS FOR INPUT AND OUTPUT CONNECTIONS
• RELIABLE SNAP-ON FOR DIN RAIL TS-35/7.5 OR TS-35/15
• CASE PROTECTION MEET IP20(IEC60529)
• INTERNAL OUTPUT DC-OK INDICATOR
• MEET EN55022 CLASS B
• SAFETY MEETS UL60950-1, EN60950-1, & IEC60950-1
• CE MARKED
• COMPLIANT TO RoHS II & REACH
1600VDC
ISOLATION
REMOTE
CONTROL
UVP
OCP
• COMMUNICATION SYSTEM
• INDUSTRY CONTROL SYSTEM
• FACTORY AUTOMATIC EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
SCP
FUSE
INCLUDED
OVP
INRUSH
LIMIT
TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃
Model
Number
DFEC60-24S3P3
DFEC60-24S05
DFEC60-24S12
DFEC60-24S15
DFEC60-24S24
DFEC60-48S3P3
DFEC60-48S05
DFEC60-48S12
DFEC60-48S15
DFEC60-48S24
REVERSE
POLARITY
PROTECTION
otherwise noted
Input Range
Output Voltage
Output Current
@Full Load
Input Current
@ No Load
Efficiency
VDC
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
VDC
3.3
5
12
15
24
3.3
5
12
15
24
A
14
12
5
4
2.5
14
12
5
4
2.5
mA
104
134
59
74
76
102
94
37
42
45
%
87
88
88
88
87
87
88
88
88
87
Maximum
Capacitor Load (1)
µF
36000
20400
3550
2300
885
36000
20400
3550
2300
885
PART NUMBER STRUCTURE
DFEC60 Series Name
1
48
Input
Voltage
(VDC)
24: 18~36
48: 36~75
S
05
Output
Quantity
Output
Voltage
(VDC)
3P3: 3.3
05: 5
12: 12
15: 15
24: 24
S: Single
-
N
Remote Control
Option
: Positive logic
N: Negative logic
www.PDUKE.com
2014/4/30
INPUT SPECIFICATIONS
Parameter
Conditions
Operating input voltage range
24Vin(nom)
48Vin(nom)
24Vin(nom)
48Vin(nom)
Input fuse (slow blow)
In-rush current
Input reflected ripple current
Start up voltage
Input surge voltage
Nominal input and
Constant resistive load
100ms, max.
Remote ON/OFF
Referred to –Vin pin
OUTPUT SPECIFICATIONS
Parameter
24Vin(nom)
48Vin(nom)
24Vin(nom)
48Vin(nom)
Power up
Remote ON/OFF
24Vin(nom)
48Vin(nom)
Positive logic
DC-DC ON
(Standard)
DC-DC OFF
Negative logic
DC-DC ON
(Option)
DC-DC OFF
Input current of Ctrl pin
Remote off input current
Conditions
Voltage accuracy
Low Line to High Line at Full Load
No Load to Full Load
Voltage adjustability
Single output
Ripple and noise
Measured by 20MHz bandwidth
Output indicator
Over load protection
Short circuit protection
Unit
36
75
VDC
3.3Vout
Others
24Vout
Others
3.3Vout, 5Vout
12Vout, 15Vout
24Vout
3.3Vout
5Vout
12Vout
15Vout
24Vout
Conditions
Isolation resistance
Isolation capacitance
Switching frequency
Safety meets
500VDC
A
mAp-p
15
32
100
20
ms
50
100
Open or 3 ~ 12VDC
Short or 0 ~ 1.2VDC
Short or 0 ~ 1.2VDC
Open or 3 ~ 12VDC
-0.5
1.0
4
Typ.
-1.5
-1.0
-0.5
-2.5
-1.5
-10
-10
Input to Output
Input (Output) to Chassis
www.PDUKE.com
VDC
mA
mA
Max.
Unit
+1.5
+1.0
+0.5
+2.5
+1.5
+20
+10
%
75
100
130
%
%
%
mVp-p
+0.02
℃
%/
µs
3.7
5.6
13.8
16.8
30.0
5.4
7.0
17.5
VDC
20.5
33.0
Green LED
150
%
Continuous, automatics recovery
Min.
Typ.
1600
1600
1
270
MIL-HDBK-217F, Full load
VDC
VDC
250
% of Iout rated; Hiccup mode
1 minute
A
17.5
34.5
-0.02
Isolation voltage
2
Single
25% load step change
Zener diode clamp
GENERAL SPECIFICATIONS
Parameter
Chassis material
Weight
MTBF
Max.
24
48
8
4
15
15
Min.
3.3Vout
Others
Line regulation
Load regulation
Temperature coefficient
Transient response recovery time
Over voltage protection
Typ.
18
36
Nominal input and Full load
Shutdown voltage
Start up time
Min.
Max.
Unit
VDC
300
GΩ
pF
kHz
UL60950-1
EN60950-1
IEC60950-1
Aluminum
182g (6.40oz)
5.296 x 105 hrs
4000
330
2014/4/30
ENVIRONMENTAL SPECIFICATIONS
Parameter
Conditions
Operating ambient temperature
Min.
Without derating
With derating
Storage temperature range
Thermal shock
Vibration
Relative humidity
EMC SPECIFICATIONS
Parameter
EMI
ESD
Radiated immunity
Fast transient
Surge
Conducted immunity
Conditions
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Typ.
-40
+55
-40
Max.
Unit
℃
℃
+55
+85
+105
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
Level
Class B
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Air ± 8kV and Contact ± 6kV
10V/m
± 2kV
± 1kV
10Vr.m.s
Note:
1.
Test by minimum input and constant resistive load.
CHARACTERISTIC CURVE
DFEC60-48S05 Derating Curve
DFEC60-48S05 Efficiency vs. Input Voltage
DFEC60-48S05 Efficiency vs. Output Load
MECHANICAL DRAWING
PIN CONNECTION
PIN
SINGLE
1
Ctrl
2
-Vin
3
-Vin
4
+Vin
5
NC
6
-Vout
7
+Vout
8
NC
* NC No Connection
* Screw terminals –
wire range from 14 to 18 AWG
:
1. All dimensions in Inch (mm)
2. Tolerance : X.XX±0.02 (X.X±0.5)
4. Tolerance : X.XXX±0.01 (X.XX±0.25)
3. Terminal screw locked torque :
MAX 2.5kgf cm (0.25N m)
-
3
www.PDUKE.com
-
2014/4/30