PAIRUI DAE1-0512H Dc-dc converter Datasheet

DC-DC Converter
SIP-Package
DAE-1H SERIES, 1WATT, 6KVDC, UNREGULATED
FEATURES:
3 years warranty
6000Vdc isolation voltage
Operating temperature range -40°C to +85°C
Low isolation capacitance
Model
Input voltage
(Vdc)
Output voltage
(Vdc)
Output current
(mA)
Min.
Max.
Efficiency
Typ.
DAE1-0511H
5
20
200
80%
DAE1-0512H
9
11
110
80%
DAE1-0513H
12
8.3
83
80%
DAE1-0514H
15
6.8
68
80%
24
4.2
42
80%
10
100
80%
5.5
55
80%
4
40
80%
3.3
33
80%
DAE1-0525H
±5
±9
±12
±15
±24
2.1
21
80%
DAE1-1211H
5
20
200
80%
DAE1-1212H
9
11
110
80%
DAE1-1213H
12
8.3
83
80%
DAE1-1214H
15
6.8
68
80%
24
4.2
42
80%
±5
±9
±12
±15
±24
10
100
80%
5.5
55
80%
4
40
80%
3.3
33
80%
2.1
21
80%
DAE1-0515H
DAE1-0521H
5(4.5~5.5)
DAE1-0522H
DAE1-0523H
DAE1-0524H
DAE1-1215H
DAE1-1221H
12(10.8~13.2)
DAE1-1222H
DAE1-1223H
DAE1-1224H
DAE1-1225H
Notes: other input and output models may available on request.
ELECTRICAL
Line regulation
---
Load regulation
10% ~ 100% full load
Ripple and noise
---
200mVp-p max.
Isolation voltage
---
6000Vdc
Operating temperature range
---
-40°C to +85°C
MTBF
---
3.5x106Hrs
www.pairuigroup.com
±1.2%
Page: 1/3
15% max.
Date: 5/26/2014
DC-DC Converter
SIP-Package
DAE-1H SERIES, 1WATT, 6KVDC, UNREGULATED
ELECTRICAL
Notes: All the data in this article are under test with “TA+25°C, humidity<75%, rated input and rated load”
mode.
MECHANICAL
CONNECTION
9.8
(0.386)
19.5
(0.768)
PIN #
SINGLE
DUAL
1
+Vin
+Vin
2
GND
GND
5
-Vo
-Vo
6
NC
COM
7
+Vo
+Vo
12.5
(0.492)
4.1
(0.161)
2.13
(0.084)
2.8
(0.11)
Note:
* Unit is mm(inch).
TEMPERATURE PROFILE
CAPACITIVE LOADS SELECTION
Single Output
Cin
(Vdc)
(μF)
5
4.7
5
10
±5
4.7
12
2.2
9
4.7
±9
2.2
24
1
12
2.2
±12
1
-
-
15/24
1
±15
0.47
www.pairuigroup.com
Voltage
Cout
Dual Output
Vin
(μF)
(Vdc)
Page: 2/3
Voltage
(Vdc)
Cout
(μF)
Date: 5/26/2014
DC-DC Converter
SIP-Package
DAE-1H SERIES, 1WATT, 6KVDC, UNREGULATED
NOTES
RECOMMENDED TEST AND APPLICATION CIRCUIT
In order to ensure the efficiency and dependability of the module, the minimum specified load must be less than 10% of
rated load. If the output power is low, we recommend to add an external 10% loading resistor in parallel.
FUSE: depends on the actual input current;
TVS: depends on the actual input voltage;
Recommended capacitor: C1, C2, C5, about 0.1uF; for C6, C7, please check the capacitive load; C3,C4: 2KV/1nF.