Vishay IHLP-1616AB-A1 Low profile, high current ihlp inductor Datasheet

IHLP-1616AB-A1
www.vishay.com
Vishay Dale
Low Profile, High Current IHLP® Inductors
FEATURES
• Shielded construction
• Lowest DCR/μH, in this package size
• Handles high transient current spikes without
saturation
• Ultra low buzz noise, due to composite
construction
• Excellent DC/DC energy storage up to 5 MHz.
Filter inductor applications up to SRF (see
“Standard Electrical Specifications” table)
• AEC-Q200 qualified
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
Manufactured under one or more of the following:
US Patents; 6,198,375/6,204,744/6,449,829/6,460,244.
Several foreign patents, and other patents pending.
APPLICATIONS
STANDARD ELECTRICAL SPECIFICATIONS
L0
INDUCTANCE
± 20 %
AT 100 kHz,
0.25 V, 0 A
(μH)
DCR
TYP.
25 °C
(m)
0.047
3.25
3.75
13.0
32.0
565
0.10
5.50
6.00
11.5
25.0
277
0.22
11.0
12.0
8.5
20.0
183
0.47
20.0
22.0
5.0
13.0
101
0.68
29.3
31.4
4.9
9.3
100
1.0
50.0
52.5
4.0
7.0
64
•
•
•
•
Engine and transmission control units
Diesel injection drivers
DC/DC converters for entertainment/navigation systems
Noise suppression for motors
- Windshield wipers
- Power seats
- Power mirrors
- Heating and ventilation blowers
- HID lighting
• LED drivers
HEAT
DCR RATING SATURATION
MAX. CURRENT CURRENT
SRF
TYP.
25 °C DC TYP.
DC TYP.
(MHz)
(A) (3)
(m)
(A) (4)
DIMENSIONS in inches [millimeters]
0.160 ± 0.010
[4.06 ± 0.254]
Notes
(1) All test data is referenced to 25 °C ambient
(2) Operating temperature range -55 °C to +125 °C
(3) DC current (A) that will cause an approximate T of 40 °C
(4) DC current (A) that will cause L to drop approximately 20 %
0
(5) The part temperature (ambient + temp. rise) should not exceed
125 °C under worst case operating conditions. Circuit design,
component placement, PWB trace size and thickness, airflow
and other cooling provisions all affect the part temperature. Part
temperature should be verified in the end application.
0.160 ± 0.010
[4.06 ± 0.254]
0.080 ± 0.002
[2.0 ± 0.05] Typical Pad Layout
0.222
[5.639]
0.175 ± 0.010
[4.45 ± 0.254]
0.090
[2.286]
0.047
[1.20]
Max.
0.076
[1.930]
0.030 ± 0.012
[0.76 ± 0.30]
DESCRIPTION
IHLP-1616AB-A1
MODEL
0.47 μH
± 20 %
INDUCTANCE VALUE
ER
INDUCTANCE TOLERANCE
e3
PACKAGE CODE
JEDEC®
LEAD (Pb)-FREE STANDARD
GLOBAL PART NUMBER
I
H
L
PRODUCT FAMILY
Revision: 15-Sep-16
P
1
6
1
6
SIZE
A
B
E
R
PACKAGE
CODE
R
4
INDUCTANCE
VALUE
7
M
TOL.
A
1
SERIES
Document Number: 34235
1
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
IHLP-1616AB-A1
www.vishay.com
Vishay Dale
PERFORMANCE GRAPHS
IHLP1616AB-A1 0.047 µH
IHLP-1616AB-A1 0.10 µH
100
0.075
100
0.10
80
0.045
60
L
0.030
40
0.015
20
0.000
0
5
10
15
20
25
30
0.08
L
0.06
60
0.04
40
0.02
20
0.00
0
80
TEMPERATURE (°C)
0.060
INDUCTANCE (µH)
ΔT °C
TEMPERATURE (°C)
INDUCTANCE (µH)
ΔT °C
0
5
10
15
20
25
30
0
DC CURRENT (A)
DC CURRENT (A)
IHLP1616AB-A1 0.22 µH
IHLP1616AB-A1 0.47 µH
0.5
100
0.20
100
0.12
60
0.08
40
0.04
20
2
4
6
8
10
12
14
16
18
20
80
L
0.3
0.2
40
0.1
20
0.0
0
22
0
1
2
3 4
5 6
IHLP-1616AB -A1 0.68 µH
8
0
9 10 11 12 13 14 15 16 17
ΔT °C
IHLP1616AB-A1 1.0 µH
1.0
100
100
0.8
80
L
0.6
60
0.4
40
0.2
20
INDUCTANCE (μH)
L
TEMPERATURE (°C)
INDUCTANCE (μH)
7
DC CURRENT (A)
DC CURRENT (A)
1.0
60
80
0.8
0.6
60
ΔT °C
0.4
40
0.2
20
0
0.0
0.0
0
2
4
DC CURRENT (A)
Revision: 15-Sep-16
6
8
0
TEMPERATURE (°C)
0.00 0
0.4
TEMPERATURE (°C)
80
L
ΔT °C
INDUCTANCE (µH)
0.16
TEMPERATURE (°C)
INDUCTANCE (µH)
ΔT °C
0
1
2
3
4
5
6
7
DC CURRENT (A)
Document Number: 34235
2
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
IHLP-1616AB-A1
www.vishay.com
Vishay Dale
PERFORMANCE GRAPHS: INDUCTANCE AND Q VS. FREQUENCY
IHLP-1616AB-A1 0.047 μH 20 %
IHLP-1616AB-A1 0.10 μH 20 %
50
0.10
0.120
50
30
0.06
L
0.04
20
0.02
10
0.00
0.1
1
0
1000
100
10
40
0.096
30
0.072
Q
Q
Q
INDUCTANCE (μH)
40
0.08
Q
0.048
20
0.024
10
0.000
0.1
1
FREQUENCY (MHz)
FREQUENCY (MHz)
IHLP-1616AB-A1 0.22 μH 20 %
IHLP-1616AB-A1 0.47 μH 20 %
0.30
100
1.0
50
0.24
80
0.8
40
0.6
30
0.4
20
0.2
10
L
0.12
40
0.06
20
0.00
0.1
1
100
10
0
1000
0.0
0.1
FREQUENCY (MHz)
IHLP-1616AB-A1 0.68 µH
40
L
Q
30
0.8
20
0.4
10
10
100
FREQUENCY (MHz)
Revision: 15-Sep-16
0
1000
INDUCTANCE (μH)
Q
1
0
1000
100
10
IHLP1616AB-A1 1.0 µH
5
50
1.6
0
0.1
1
FREQUENCY (MHz)
2
1.2
L
Q
60
0.18
INDUCTANCE (μH)
Q
Q
INDUCTANCE (μH)
Q
INDUCTANCE (μH)
0
1000
100
10
50
4
40
Q
3
30
Q
INDUCTANCE (μH)
L
L
2
20
1
10
0
0
0.1
1
10
100
FREQUENCY (MHz)
Document Number: 34235
3
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer

ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Revision: 13-Jun-16
1
Document Number: 91000
Similar pages