AIMTEC AMEL3-15SBAZ Ac-dc converter Datasheet

Series AMEL3-AZ
3Watt | AC-DC Converter
FEATURES:
•
•
•
•
•
Models
Single output
I/O Isolation 3000VAC
Operating Temp: -40oC to +80oC
Over Load,Short Circuit Protection
Input: 90-305VAC, 47-440Hz, or 130-430 VDC
Optional 90-528Vac, 47-440Hz, or 130-745 VDC
• RoHS compliant
• Energy Star compliant
• Ultra small package
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
Output
Current max
(mA)
AMEL3-3.3SAZ
AMEL3-5SAZ
AMEL3-12SAZ
AMEL3-15SAZ
AMEL3-24SAZ
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
130-430
130-430
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
3.3
5
12
15
24
900
600
250
200
125
AMEL3-3.3SBAZ
AMEL3-5SBAZ
AMEL3-12SBAZ
AMEL3-15SBAZ
AMEL3-24SBAZ
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
130-745
130-745
130-745
130-745
130-745
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
3.3
5
12
15
24
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
AMEL3-5DAZ
AMEL3-12DAZ
AMEL3-15DAZ
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
-40 to +80
-40 to +80
-40 to +80
±5
±12
±15
300
125
100
AMEL3-5DBAZ
AMEL3-12DBAZ
AMEL3-15DBAZ
90-528/47-440
90-528/47-440
90-528/47-440
130-745
130-745
130-745
-40 to +80
-40 to +80
-40 to +80
±5
±12
±15
300
125
100
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
AMEL3-512DAZ
90-305/47-440
130-430
-40 to +80
5/12
200/83
AMEL3-512DBAZ
90-528/47-440
130-745
-40 to +80
5/12
200/83
Model
230
277
2200
1100
680
560
470
70
70
76
77
79
68
69
74
74
78
66
66
72
70
76
700
600
250
200
125
2200
1100
680
560
470
62
70
75
76
73
61
71
75
77
73
61
70
74
76
73
Output
Current max
(mA)
Maximum
capacitive
Load
(µF)
Models
Dual Asymmetrical output
Model
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
www.aimtec.com
F 052e R8.C
Output
Voltage
(V)
Output
Current max
(mA)
Conditions
Typical
Recommended slow blow type
1
≦0.5
115 VAC
230 VAC
277 VAC
480VAC
115 VAC
230 VAC
277 VAC
480 VAC
Tel: +1 514 620 2722
1 of 4
Efficiency
(%)
115
Models
Dual output
Model
Maximum
capacitive
Load
(µF)
VAC
VAC
VAC
230
277
1100
680
330
71
74
75
72
74
75
71
73
74
1100
680
330
70
73
74
71
73
74
70
72
73
VAC
VAC
VAC
230
277
1100
69
69
65
1100
68
68
64
80
45
40
15
10
15
20
30
0.15
56
63
66
69
65
480
VAC
64
65
65
Efficiency
(%)
115
Maximum
VAC
Efficiency
(%)
115
Maximum
capacitive
Load
(µF)
480
VAC
VAC
VAC
480
VAC
60
Units
mA
mA
mA
mA
A
A
A
A
mA
A
W
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL3-AZ
Single Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Transient Recovery Time
Transient Response Deviation
Minimum load
3Watt | AC-DC Converter
Conditions
Typical
Conditions
Typical
Conditions
Typical
Full load (typical)*
LL-HL, Full Load
0-100% load (typical)*
±5
±5
±5
100
25% load step
±2
0
3.3V&5V with 680 μF(E/C)
300
Ripple & Noise
12V&15V with 220uF (E/C)
300
24V with 470 uF (E/C)
200
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1μFM/C and115/230/277/480VAC(typical input) with Full Load.
Dual Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Cross regulation
Transient Recovery Time
Transient Response Deviation
Minimum load
Full load
LL-HL
0-100% load
25% load change
±5
±5
±5
±5
200
25% load step
±2
0
5D/12D/15D with 220uF (E/C)
200
Ripple & Noise
512D with 220uF (E/C)
300
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1μFM/C and 115/230/277/480VAC (typical input) with Full Load.
*5D/12D/15D Model with symmetric load change and 512D Model with asymmetric load change.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
30sec
General Specifications
Parameters
Switching frequency
Over Load protection
Short circuit protection
Operating temperature
Storage temperature
Maximum Case temperature
Humidity
Case material
Weight
>1000
Conditions
Typical
100
>125%
Auto recovery
Fold back
See de-rating chart
-40 to +80
-40 to +85
Maximum
Maximum
Units
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
mV p-p
Units
%
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
Rated
Units
Maximum
Units
3000
VAC
MΩ
KHz
o
100
C
C
% RH
o
Non condensing
20~95
Plastic resin + Fiberglass (flammability to UL 94V-0)
21
g
90-305VAC
1.10 x 0.90 x 0.57 inches (28.00 x 23.00 x 14.50 mm)
Dimensions (L x W x H)
90-528VAC
1.10 x 0.90 x 0.67 inches (28.00 x 23.00 x 17.00 mm)
o
MTBF
>400 000 hrs (MIL-HDBK -217F, t=+25 C)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Environment Approval
Parameters
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Shock
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Vibrations
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
www.aimtec.com
F 052e R8.C
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL3-AZ
3Watt | AC-DC Converter
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB (underspecification), CSA
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity (1KV)
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Canadian Safety Agency
IEC/EN/UL 60950-1:2006+A11:2009
EN55022, class B
IEC/EN 61000-3-2, (EN60555-2)
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5(SAZ &DAZ:Level2,SBAZ&DBAZ:Level 1)
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
CAN/CSA-C22.2 NO. 60950-1-07
Derating
Free Air Convection
Output Power %
100
55 ºC
80
Safe Operating Area
60
50
40
25
20
0
-40
-25
0
20
40
55
60
70
80
100
Ambient Temperature º C
Pin Out Specifications
Pin
Single
1
2
3
4
5
6
7
NC
NC
+V Output
GND
No Pin
AC Input (L)
AC Input (N)
www.aimtec.com
F 052e R8.C
Dual
NC
NC
+V Output
GND
-V Output
AC Input (L)
AC Input (N)
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL3-AZ
3Watt | AC-DC Converter
Dimensions
28.00
(1.10)
3.175 3.175
(0.125) (0.125)
1
4
3
1
5
Top View
3
4
5
Temperature measuring point
23.00
15.875
Top View
(0.90)
2
14.50
(0.625)
7
6
15.875
6.35
(0.625)
(0.25)
2
7
DIV: 5.00 (0.20)
1£ X
10.0 ( £ X
0.40)
AMEL-S/DAZ
Side View
(0.57)
6
7£ X
0.80 ( £ X
0.03)
3.18
(0.13)
Dimensions mm (inch)
Case Tolerance ¡ Ó
0.50 (¡ Ó
0.02)
Pin Diameter 0.80¡ Ó
0.05 (0.03¡ Ó
0.002)
Pin Pitch Tolerance ¡ Ó
0.50 (¡ Ó
0.02)
0.80
(0.03)
17.00
AMEL-SB/DBAZ
Side View
(0.69)
3.18
(0.13)
0.80
(0.03)
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications.2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.C
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages