Vishay MUR440-M3 Ultrafast plastic rectifier Datasheet

MUR440-M3, MUR460-M3
www.vishay.com
Vishay General Semiconductor
Ultrafast Plastic Rectifier
FEATURES
• Glass passivated pellet chip junction
• Ultrafast reverse recovery time
• Low forward voltage drop
• Low leakage current
• Low switching losses, high efficiency
• High forward surge capability
• Solder dip 275 °C max. 10 s, per JESD 22-B106
DO-201AD
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
TYPICAL APPLICATIONS
PRIMARY CHARACTERISTICS
For use in high frequency rectification and freewheeling
application in switching mode converters and inverters for
consumer, computer, and telecommunication.
IF(AV)
4.0 A
VRRM
400 V, 600 V
IFSM
150 A
MECHANICAL DATA
trr
50 ns
VF at IF
1.05 V
Case: DO-201AD
Molding compound meets UL 94 V-0 flammability rating
Base P/N-M3 - halogen-free, RoHS-compliant, and
commercial grade
TJ max.
175 °C
Package
DO-201AD
Diode variations
Single die
Terminals: Matte tin plated leads, solderable
J-STD-002 and JESD 22-B102
M3 suffix meets JESD 201 class 1A whisker test
per
Polarity: Color band denotes cathode end
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
MUR440
MUR460
UNIT
Maximum repetitive peak reverse voltage
VRRM
400
600
V
Working peak reverse voltage
VRWM
400
600
V
Maximum DC blocking voltage
VDC
400
600
V
Maximum average forward rectified current (fig. 1)
IF(AV)
4.0
A
Peak forward surge current 8.3 ms single half sine-wave superimposed on rated load
IFSM
150
A
TJ, TSTG
-65 to +175
°C
Operating junction and storage temperature range
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
Maximum instantaneous forward voltage
TEST CONDITIONS
3.0 A
4.0 A
Maximum instantaneous reverse current
at rated DC blocking voltage
SYMBOL
TJ = 150 °C
TJ = 25 °C
TJ = 25 °C
TJ = 150 °C
MUR440
MUR460
UNIT
1.05
VF (1)
1.25
V
1.28
IR (1)
10
250
μA
Max. reverse recovery time
IF = 0.5, IR = 1.0 A, Irr = 0.25 A
trr
50
ns
Maximum reverse recovery time
IF = 1.0 A, dI/dt = 50 A/μs, VR = 30 V, Irr = 10 % IRM
trr
75
ns
Maximum forward recovery time
IF = 1.0 A, dI/dt = 100 A/μs, recovery to 1.0 V
tfr
50
ns
Note
(1) Pulse test: t = 300 μs, duty cycle 2 %
p
Revision: 19-Feb-16
Document Number: 89187
1
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
MUR440-M3, MUR460-M3
www.vishay.com
Vishay General Semiconductor
THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
MUR440
MUR460
RJA (1)
Typical thermal resistance junction to ambient
UNIT
28
°C/W
Note
(1) Lead length = 1/2" on PCB with 1.5" x 1.5" copper surface
ORDERING INFORMATION (Example)
PREFERRED P/N
UNIT WEIGHT (g)
PREFERRED PACKAGE CODE
BASE QUANTITY
DELIVERY MODE
MUR460-M3/54
1.138
54
1400
13" diameter paper tape and reel
MUR460-M3/73
1.138
73
1000
Ammo pack packaging
RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted)
100
Instantaneous Forward Current (A)
Average Forward Rectified Current (A)
6.0
L = 1/2"
4.0
P.C.B. with 1.5 x 1.5"
Copper Pads
2.0
50
100
150
200
1
TJ = 100 °C
0.1
TJ = 25 °C
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
Ambient Temperature (°C)
Instantaneous Forward Voltage (V)
Fig. 1 - Forward Current Derating Curve
Fig. 3 - Typical Instantaneous Forward Characteristics
150
1000
Instantaneous Reverse Leakage
Current (µA)
Peak Forward Surge Current (A)
TJ = 175 °C
0.01
0.2
0
0
10
125
100
75
50
25
0
1
10
100
100
TJ = 175 °C
10
TJ = 100 °C
1
0.1
TJ = 25 °C
0.01
0.001
0
20
40
60
80
Number of Cycles at 60 Hz
Percent of Rated Peak Reverse Voltage (%)
Fig. 2 - Maximum Non-Repetitive Peak Forward Surge Current
Fig. 4 - Typical Reverse Characteristics
100
Revision: 19-Feb-16
Document Number: 89187
2
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
MUR440-M3, MUR460-M3
www.vishay.com
Vishay General Semiconductor
Junction Capacitance (pF)
1000
TJ = 25 °C
f = 1.0 MHz
Vsig = 50 mVp-p
100
10
0.1
1
10
100
Reverse Voltage (V)
















Fig. 5 - Typical Junction Capacitance Per Leg
PACKAGE OUTLINE DIMENSIONS in inches (millimeters)
DO-201AD
1.0 (25.4)
MIN.
0.210 (5.3)
0.190 (4.8)
DIA.
0.375 (9.5)
0.285 (7.2)
1.0 (25.4)
MIN.
0.052 (1.32)
0.048 (1.22)
DIA.
Revision: 19-Feb-16
Document Number: 89187
3
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer

ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Revision: 13-Jun-16
1
Document Number: 91000
Similar pages