XP Power A50 Isolated, proportional dc to hv dc converter Datasheet

Proven
Reliabilit y
A SERIES
ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS
100V to 6000V @ 1.0 and 1.5 Watts
Extremely Low Profile: 0.25 inches
and volume of < 0.100 cubic inches
PRODUCT SELECTION TABLE
*5
VDC
UL
NOW
IZED
N
G
O
REC
PRODUCT DESCRIPTION
The A Series is a new line of ultra-miniature, DC to HV DC converters that set an industry standard in high voltage miniaturization.
This unique package occupies less than one tenth of a cubic inch of
volume*5, and features an extremely low profile of only 0.250 inches
(6.35mm)! Controllable output voltages range from 100 volts to 6000
volts. These component-sized converters are ideal for applications
requiring minimal size and weight. Please refer to our AG series
data sheet for surface mount options.
1.5 WATT OPTION AH MODEL
STANDARD 1 WATT A MODEL
MODEL
MAXIMUM
OUTPUT
CURRENT*1
MODEL
MAXIMUM
OUTPUT
CURRENT*1
100 VDC
A01
10 mA
AH01
15 mA
200 VDC
A02
5 mA
AH02
7.5 mA
250 VDC
A025
4 mA
AH025
6 mA
300 VDC
A03
3.33 mA
AH03
5mA
400 VDC
A04
2.5 mA
AH04
3.75 mA
500 VDC
A05
2 mA
AH05
3 mA
600 VDC
A06
1.67 mA
AH06
2.5 mA
700 VDC
A07
1.43 mA
AH07
2.15 mA
800 VDC
A08
1.25 mA
AH08
1.87 mA
900 VDC
A09
1.1 mA
AH09
1.67 mA
1000 VDC
A10
1 mA
AH10
1.5 mA
1200 VDC
A12
0.83 mA
AH12
1.25 mA
1500 VDC
A15
0.66 mA
AH15
1 mA
2000 VDC
A20
0.5 mA
AH20
0.75 mA
3000 VDC
A30
0.32 mA
AH30
0.5 mA
4000 VDC
A40
0.24 mA
–
–
5000 VDC
A50
0.2 mA
–
–
6000 VDC
A60
0.167 mA
AH60
0.25 mA
Complete List of Models on page 2
APPLICATIONS
Avalanche Photodiodes
Capacitor Charging
Electrophoresis
Photomultiplier Tubes
Piezo Devices
Mass Spectrometry
Sustaining Ion Pumps
OPTIONS
1 Watt and 1.5 Watt Versions Available (A/AH)
Three Input Voltage Ranges: 0 to 5, 12, or 24VDC (5V only above 3KV)
Polarity: Choose Positive or Negative Output (P/N)
Extended Operating Temperature (A Models / 1.0W) (T Suffix)
Alternate Input / Output Voltages (Consult Factory)
See Ordering Information (Page 11)
WWW.XPPOWER.COM
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
Proportional Input/Output
Low Noise Quasi-sinewave Oscillator
Control Pin
Low Leakage Current
Low Input/Output Capacitance
Input to Output Galvanic Isolation
Short Circuit Protection, 1 Minute Minimum
No Minimum Load Required*2
MTBF > 1,862,000 hours, per Bellcore TR 332
No External Components Required
RoHS Compliant
UL Recognized
E344664
4389U04
PAGE 1
A SERIES
ELECTRICAL SPECIFICATIONS*3
STANDARD 1 WATT - A MODEL
OUTPUT VOLTAGE*
2
1.5 WATT OPTION - AH MODEL
(To select polarity, see pg. 10 - How to Order)
MODEL
MAXIMUM
OUTPUT
CURRENT*1
RIPPLE
P-P*4
MODEL
MAXIMUM
OUTPUT
CURRENT*1
RIPPLE
P-P*4
0 to 100 VDC
A01
10 mA
5%
AH01
15 mA
2%
0 to 200 VDC
A02
5 mA
1%
AH02
7.5 mA
3%
0 to 250 VDC
A025
4 mA
.90%
AH025
6 mA
1.2%
0 to 300 VDC
A03
3.33 mA
.70%
AH03
5 mA
.70%
0 to 400 VDC
A04
2.5mA
.50%
AH04
3.75 mA
.75%
0 to 500 VDC
A05
2 mA
.50%
AH05
3 mA
.70%
0 to 600 VDC
A06
1.67 mA
1%
AH06
2.5 mA
2%
0 to 700 VDC
A07
1.43 mA
.50%
AH07
2.15 mA
1.2%
0 to 800 VDC
A08
1.25 mA
1%
AH08
1.87 mA
1.2%
0 to 900 VDC
A09
1.1 mA
1%
AH09
1.67 mA
1.2%
0 to 1000 VDC
A10
1 mA
.79%
AH10
1.5 mA
1%
0 to 1200 VDC
A12
0.83 mA
.50%
AH12
1.25 mA
.60%
0 to 1500 VDC
A15
0.67 mA
.40%
AH15
1 mA
.60%
0 to 2000 VDC
A20
0.5 mA
.30%
AH20
0.75 mA
.50%
0 to 3000 VDC
A30
0.33 mA
.20%
AH30
0.5 mA
.20%
0 to 4000 VDC
A40
0.25 mA
.12%
–
–
–
0 to 5000 VDC
A50
0.2 mA
.15%
–
–
–
0 to 6000 VDC
A60
0.167 mA
.15%
AH60
0.25 mA
.25%
INPUT CURRENT
A MODELS – 1 Watt
AH MODELS – 1.5 Watt
VIN
NO-LOAD
FULL-LOAD
NO-LOAD
FULL-LOAD
5 VDC
<300mA
<500mA
<300mA
<550mA
12 VDC
<100mA
<185mA
<125mA
<250mA
24 VDC
<25mA
<60mA
<40mA
<120mA
0 TO 5V ONLY (FOR MODELS OVER 3kV)
WWW.XPPOWER.COM
4389U04
PAGE 2
A SERIES
ELECTRICAL SPECIFICATIONS*3
PARAMETER
VALUE
0 TO 5, 12, OR 24V (FOR MODELS UP TO 3KV)
INPUT VOLTAGE
0 TO 5V (FOR MODELS OVER 3KV)
TURN-ON VOLTAGE
<0.7 VDC
ISOLATION
< +/- 500V BIAS ON PIN 4
OUTPUT VOLTAGE TOLERANCE
+10%, -10% FULL LOAD, MAX. INPUT VOLTAGE
INPUT/OUTPUT COUPLING CAPACITANCE
<250 pf TYPICAL
INPUT/OUTPUT LEAKAGE CURRENT
<100 nA TYPICAL
CONTROL PIN
0 to MAX. INPUT VOLTAGE
INTERNAL OSCILLATOR FREQUENCY
50kHz - 350kHz
OPERATING: -25° TO +75°C*6 (CASE)
STANDARD TEMPERATURE RANGES
STORAGE: -55° TO +105°C
EXTENDED TEMPERATURE RANGES (-T OPTION)
OPERATING: -55 TO +85°C*6 (CASE) [A Models / 1.0W]
STORAGE: -55° TO +105°C
DETAILED PRODUCT DESCRIPTION
The A Series is a new line of ultra-miniature, DC to HV DC converters that
set an industry standard in high voltage miniaturization. This unique package occupies less than one tenth of a cubic inch of volume*5, and features
an extremely low profile of only 0.250 inches (6.35mm)! Controllable output voltages range from 100 volts to 6000 volts. These component-sized
converters are ideal for applications requiring minimal size and weight.
Output power is 1 watt standard, with 1.5 watts available as an option. No
minimum load is required. A proprietary vacuum encapsulation process and
custom 94V-0 listed, high performance formula are used to achieve excellent
high voltage and thermal properties. Isolation is +/- 500V bias on the output
return. Input to output leakage current is very low at less than 100 nA and
coupling capacitance is also low at <250 pF.
Turn-on voltage is very low at less than 0.7 volts, allowing for wide output
voltage operating range. Use of a resonant, quasi-sinewave oscillator and
fully shielded transformer result in clean, reliable high voltage conversion
with inherently low ripple, EMI/RFI and input ripple current, making this
product ideal for integration into noise sensitive equipment.
The new A Series leverages XP EMCO’s Best-in-Class long term reliability, utilizing proven DC to high voltage DC conversion technology,
perfected by over four decades of high voltage design experience in the
most demanding applications. Our extensive in-house capabilities enable
us to meet specific customer requirements with standard, modified and
custom solutions quickly, easily, and economically. Technical assistance is
readily available.
A separate high impedance control pin is standard and is designed for
external error amplifier and/or DAC control in closed or open loop systems.
Or simply connect the control pin to the + input for proportional input to
output operation (see schematic and performance charts below).
WWW.XPPOWER.COM
4389U04
PAGE 3
A and AH SERIES
MECHANICAL SPECIFICATIONS (100V - 2,000V)
TOP VIEW
SIDE VIEW
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127)
PARAMETER
VALUE
PIN #
FUNCTION
WEIGHT
< 0.20 OZ. (5.66 GRAMS)
1
(–) INPUT
VOLUME
< 0.10 CUBIC INCHES (1.696 CUBIC CENTIMETERS)
2
(+) INPUT
DIMENSIONS
0.92L (23.37L) x 0.45W (11.43W) x 0.25H (6.35H)
3
HV OUT
4
HV RTN
5
CONTROL
WWW.XPPOWER.COM
4389U04
PAGE 4
A and AH SERIES
MECHANICAL SPECIFICATIONS (3,000V - 5,000V)
TOP VIEW
SIDE VIEW
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127)
PARAMETER
VALUE
PIN #
FUNCTION
WEIGHT
< 0.25OZ (7.09 GRAMS)
1
(–) INPUT
VOLUME
< 0.12 CUBIC INCHES (2.082 CUBIC CENTIMETERS)
2
(+) INPUT
DIMENSIONS
1.129L (28.69L) x 0.45W (11.43W) x 0.25H (6.35H)
3
HV OUT
4
HV RTN
5
CONTROL
WWW.XPPOWER.COM
4389U04
PAGE 5
A and AH SERIES
MECHANICAL SPECIFICATIONS (6,000V)
TOP VIEW
SIDE VIEW
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127)
PARAMETER
VALUE
PIN #
FUNCTION
WEIGHT
< 0.30 OZ. (8.49 GRAMS)
1
(–) INPUT
VOLUME
< 0.15 CUBIC INCHES (2.45 CUBIC CENTIMETERS)
2
(+) INPUT
DIMENSIONS
1.33L (33.78L) x 0.45W (11.43W) x 0.25H (6.35H)
3
HV OUT
4
HV RTN
5
CONTROL
WWW.XPPOWER.COM
4389U04
PAGE 6
A SERIES
MECHANICAL SPECIFICATIONS
100V - 2,000V
need updated
drawing
NOTE: No traces to be routed within the
shaded area on the component side of
the PWB.
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127)
3,000 - 5,000V
NOTE: No traces to be routed within the
shaded area on the component side of
the PWB.
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127)
WWW.XPPOWER.COM
4389U04
PAGE 7
A SERIES
MECHANICAL SPECIFICATIONS
6,000V
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
DIMENSIONAL TOLERANCES: .XX = +- 0.02 (0.51), .XXX = +- 0.005 ( 0.127)
WWW.XPPOWER.COM
4389U04
PAGE 8
A SERIES
APPLICATION NOTES
Typical HV Output vs. Control Voltage
Typical HV Output
vs. Control Voltage
300
Full Load Output
No Load Output (A)
No Load Output (AH)
Safe Operating Limit
250
% HV Output
200
150
100
50
0
0
10
20
30
40
50
60
70
80
90
100
% Control Voltage
NOTE: Vin held at maximum
TYPICAL INPUT vs. OUTPUT VOLTAGE
Typical Input
vs. Output Voltage
100
loaded
unloaded (A)
90
unloaded (AH)
80
% OUTPUT VOLTAGE
70
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
90
100
% INPUT VOLTAGE
NOTE: Control Pin tied to Vin Pin
Output Voltage is load dependent. Under light or no-load conditions, reduce
the Input Voltage so maximum rated Output Voltage is not exceeded.
WWW.XPPOWER.COM
4389U04
PAGE 9
A SERIES
OPTION CODES
ORDERING INFORMATION
OUTPUT VOLTAGE
POLARITY DESIGNATOR
INPUT VOLTAGE
STANDARD TEMPERATURE RANGES
EXTENDED TEMPERATURE RANGES
ORDER CODE
1 WATT
A
1.5 WATT
AH
POSITIVE OUTPUT
P
NEGATIVE OUTPUT
N
5 VDC
5
12 VDC
12
24 VDC
24
OPERATING: -25 TO +75°C*6 (CASE)
BLANK
STORAGE: -55 TO +105°C
BLANK
OPERATING: -55 TO +85°C*6 (CASE) [A Models / 1.0W]
T
STORAGE: -55 TO +105°C
T
HOW TO ORDER
PART NUMBER SELECTOR:
Model Number:
A 20 N - 12 T
A - Model
20 - Output Voltage/100 (See table)
N - Polarity Designator
T - Extended Operating Temperature
12 - Input Voltage
EXAMPLE: A20N-12T (A - Model, 20 - Output Voltage, N - Negative, 12 - Input Voltage, T - Extended Operating Temperature)
*Note:
1. At maximum rated output voltage
2. Output Voltage is load dependent. Under light or no-load conditions, reduce the Input Voltage so maximum rated Output Voltage is not exceeded.
3. Specifications after 30 minute warm-up, full-load, at 25ºC, unless otherwise noted.
4. Ripple may be reduced substantially by the addition of an external RC filter.
5. Volume will vary depending on package size.
6. Proper thermal management techniques are required to maintain safe case temperature at maximum power output.
XP EMCO reserves the right to make changes on products and literature, including specifications, without notice. XP EMCO standard product models are not recommended for “copy-exact” applications or any other application restricting product
changes. “Copy-exact” options are available. Please contact an XP EMCO sales representative for more details.
WWW.XPPOWER.COM
4389U04
PAGE 10
Similar pages