P-DUKE FKC15-48S12 Dc-dc converter Datasheet

FKC15 SERIES
DC-DC CONVERTER
2:1 WIDE INPUT RANGE
UP TO 15 Watts
FEATURES
APPLICATIONS
• NO MINIMUM LOAD REQUIRED
• 1600VDC INPUT TO OUTPUT ISOLATION
• STANDARD 1.25 X 0.80 X 0.40 INCH AND 24 PIN DIP PACKAGE
• UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
1600VDC
ISOLATION
REMOTE
CONTROL
UVP
OCP
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• DISTRIBUTED POWER ARCHITECTURES
• SEMICONDUCTOR EQUIPMENT
SCP
LOW
STANDBY
POWER
TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted
Model
Number
Input Range
Output Voltage
Output Current
@Full Load
Input Current
@ No Load
Efficiency
Maximum
Capacitor Load
VDC
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
VDC
3.3
5.1
12
15
±5
±12
±15
3.3
5.1
12
15
±5
±12
±15
3.3
5.1
12
15
±5
±12
±15
mA
4000
3000
1250
1000
±1500
±625
±500
4000
3000
1250
1000
±1500
±625
±500
4000
3000
1250
1000
±1500
±625
±500
mA
10
10
5
10
10
6
10
6
6
4
6
4
6
6
4
4
4
4
4
4
4
%
87
90
90
90
86
90
90
88
90
91
91
87
90
90
88
90
90
91
87
90
90
µF
4700
3300
600
400
±1500
±288
±200
4700
3300
600
400
±1500
±288
±200
4700
3300
600
400
±1500
±288
±200
FKC15-12S3P3
FKC15-12S05
FKC15-12S12
FKC15-12S15
FKC15-12D05
FKC15-12D12
FKC15-12D15
FKC15-24S3P3
FKC15-24S05
FKC15-24S12
FKC15-24S15
FKC15-24D05
FKC15-24D12
FKC15-24D15
FKC15-48S3P3
FKC15-48S05
FKC15-48S12
FKC15-48S15
FKC15-48D05
FKC15-48D12
FKC15-48D15
PART NUMBER STRUCTURE
FKC15 - 48
Series Name
Input
Voltage
(VDC)
12: 9~18
24:18~36
48:36~75
S
05
Output
Quantity
Output
Voltage
(VDC)
3P3: 3.3
05: 5.1
12:12
15:15
S:Single
D: Dual
1
05:± 5
12:±12
15:±15
www.PDUKE.com
2014/04/30
FKC15
INPUT SPECIFICATIONS
Parameter
Conditions
Operating input voltage range
12Vin(nom)
24Vin(nom)
48Vin(nom)
12Vin(nom)
24Vin(nom)
48Vin(nom)
12Vin(nom)
24Vin(nom)
48Vin(nom)
Power up
Remote ON/OFF
12Vin(nom)
24Vin(nom)
48Vin(nom)
Start up voltage
Shutdown voltage
Start up time
Constant resistive load
Input surge voltage
1 second, max.
Input reflected ripple current
Input filter
Remote ON/OFF
Referred to –Vin pin
No Load to Full Load
10% Load to 90% Load
Asymmetrical load 25%/100% FL
20MHz bandwidth
With a 1µF/25V X7R MLCC
Min.
Single
Dual
Single
Dual
Single
Dual
Dual
VDC
VDC
ms
VDC
mAp-p
Pi type
Open or 3.0 ~ 12VDC
Short or 0 ~ 1.2VDC
+0.5
2.5
Typ.
-1.0
-0.2
-0.5
-0.5
-1.0
-0.3
-0.8
-5.0
Unit
+1.0
+0.2
+0.5
+0.5
+1.0
+0.3
+0.8
+5.0
%
% of Iout rated; Hiccup mode
Isolation voltage
1 minute
Isolation resistance
Isolation capacitance
Switching frequency
Safety approvals
500VDC
Conditions
Input to Output
Input (Output) to Case
www.PDUKE.com
%
%
mVp-p
+0.02
%/
250
µs
3.9
6.2
VDC
15
18
150
%
Continuous, automatics recovery
Min.
1600
1600
1
297
MIL-HDBK-217F
%
℃
-0.02
3.3Vout
5.1Vout
12Vout
15Vout
mA
mA
Max.
60
25% load step change
GENERAL SPECIFICATIONS
Parameter
2
-0.5
Unit
VDC
60
60
36
50
100
Conditions
Load regulation
Case material
Base material
Potting material
Weight
MTBF
18
36
75
9
18
36
8
16
33
DC-DC ON
DC-DC OFF
Input current of Ctrl pin
Remote off input current
Low Line to High Line at Full Load
Over load protection
Short circuit protection
Max.
12
24
48
Positive logic
Voltage accuracy
Line regulation
Temperature coefficient
Transient response recovery time
Over voltage protection
Typ.
9
18
36
20
OUTPUT SPECIFICATIONS
Parameter
Cross regulation
Ripple and noise
Min.
Typ.
Max.
Unit
VDC
GΩ
pF
330
kHz
UL60950-1
EN60950-1
IEC60950-1
Nickel-coated copper
FR4 PCB
Silicone (UL94 V-0)
14.4g (0.51oz)
1.797 x 106 hrs
2000
363
2014/04/30
FKC15
ENVIRONMENTAL SPECIFICATIONS
Parameter
Conditions
Min.
3.3Vout, ±5Vout
Operating ambient temperature
Without derating
With derating
Without derating
With derating
Others
Maximum case temperature
Storage temperature range
Thermal impedance
Thermal shock
Vibration
Relative humidity
Max.
+60
+100
+73
+100
105
+125
-55
Natural convection
20
Unit
℃
℃
℃
℃/W
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
EMC SPECIFICATIONS
Parameter
EMI(1)
ESD
Radiated immunity
Fast transient (2)
Surge (2)
Conducted immunity
Typ.
-40
+60
-40
+73
Conditions
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Level
Class A,Class B
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Air ± 8kV and Contact ± 6kV
10 V/m
± 2kV
± 2kV
10 Vr.m.s
Note:
1.
2.
The standard modules meet EMI Class A or Class B with external components. For further information, please contact with P-DUKE.
An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter Power Mate suggests: Nippon chemi-con KY series, 220µF/100V.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
FKC15-48S05 Derating Curve
FKC15-48S05 Efficiency vs. Input Voltage
FKC15-48S05 Efficiency vs. Output Load
MECHANICAL DRAWING
PIN CONNECTION
PIN
SINGLE
1
Ctrl
2
-Vin
3
-Vin
9
11
NC
NC
DUAL
Ctrl
-Vin
-Vin
PIN
SINGLE
DUAL
23
22
+Vin
+Vin
+Vin
+Vin
Common
-Vout
16
14
-Vout
+Vout
Common
+Vout
1. All dimensions in inch (mm)
2. Tolerance :x.xx±0.02 (x.x±0.5)
x.xxx±0.01 (x.xx±0.25)
3. Pin pitch tolerance ±0.01 (0.25)
4. Pin dimension tolerance ±0.004(0.1)
3
www.PDUKE.com
2014/04/30