Omron G3TC-OAC5A Solid state relays for industrial i/o Datasheet

Solid State Relays for Industrial I/O
G3TC
Reliable SSRs for I/O Module Mounting
Boards
• Use I/O SSRs as an interface between logic circuitry and the load.
• Variety of AC/DC input and output modules with industry-standard
footprint and color coding.
• Built-in hold down screw fastens relay to board to eliminate loosening by vabration.
• Optical Isolation - Dielectric strength of 4 kV between input and output terminals.
• Zero cross function on AC output models.
• AC and DC input versions incorporate a rectifier to accept both AC
or DC inputs.
• UL, CSA and TUV approved; marked with CE.
Ordering Information
■ Input Module
Function
Color
AC input
Isolation
Yellow
Photo-coupler
Input operating
voltage range
90-140 VDC/AC
180-280 VDC/AC
DC input
White
10-32 VDC/AC
Logic level output
supply voltage
Model
5 VDC
G3TC-IAC5 AC/DC120
15 VDC
G3TC-IAC15 AC/DC120
24 VDC
G3TC-IAC24 AC/DC120
5 VDC
G3TC-IAC5A AC/DC240
15 VDC
G3TC-IAC15A AC/DC240
24 VDC
G3TC-IAC24A AC/DC240
5 VDC
G3TC-IDC5 DC/AC24
15 VDC
G3TC-IDC15 DC/AC24
24 VDC
G3TC-IDC24 DC/AC24
■ Output Module
Function
AC output
Color
Black
Isolation
Photo-triac
Rated input
voltage
5 VDC
15 VDC
Rated output voltage
(Applicable output voltage)
3 A at 120 VAC
(3 A at 75-140 VAC)
24 VDC
5 VDC
15 VDC
Red
Photo-coupler
5 VDC
15 VDC
15 VDC
24 VDC
G3TC-OAC15 DC15
G3TC-OAC5A DC5
G3TC-OAC15A DC15
G3TC-OAC24A DC24
3 A at 60 VDC
(3 A at 5-60 VDC)
24 VDC
5 VDC
G3TC-OAC5 DC5
G3TC-OAC24 DC24
3 A at 240 VAC
(3 A at 75-280 VAC)
24 VDC
DC output
Model
G3TC-ODC5 DC5
G3TC-ODC15 DC15
G3TC-ODC24 DC24
1 A at 200 VDC
(1 A at 5-200 VDC)
G3TC-ODC5A DC5
G3TC-ODC15A DC15
G3TC-ODC24A DC24
Solid State Relays for Industrial I/O
G3TC
395
■ Typical Applications
• HVAC, refrigeration equipment
• Automation controls
• Injection molding machines
• Packaging equipment
■ I/O Classification by Color
Specifications
■ Common Characteristics
Insulation resistance
100 MΩ min at 500 VDC
Dielectric strength
4000 VAC, 50/60 Hz for 1 minute between input and output
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance
Malfunction: 1,000 m/s2
Ambient temperature
Operating: -30°C to 80°C with no icing or condensation
Storage: -30°C to 100°C with no icing or condensation
Ambient humidity
Operating: 45% to 85%
Approved standards
UL Recognized, CSA Certified, EN60950
396
G3TC
Solid State Relays for Industrial I/O
■ AC Input Module G3TC-IAC
Ratings (Ambient Temperature 25°C)
Input
Item
G3TC-IAC5
G3TC-IAC15
G3TC-IAC24
G3TC-IAC5A
G3TC-IAC15A
Rated voltage
120 VAC/DC
240 VAC/DC
Operating voltage
90-140 VAC/DC
180-280 VAC/DC
Must operate voltage
90 VAC/DC max.
180 VAC/DC max.
Must release voltage
25 VAC/DC min.
45 VAC/DC min.
Input current at rated voltage
5 mA max.
5 mA max.
Input resistance (see note 1)
30 kΩ
69 kΩ
G3TC-IAC24A
Output
Item
G3TC-IAC5
G3TC-IAC15
G3TC-IAC24
15 VDC
24 VDC
G3TC-IAC5A
5 VDC
G3TC-IAC15A
15 VDC
G3TC-IAC24A
Output supply voltage-nominal
5 VDC
24 VDC
Output supply voltage-range
4.5-6 VDC
12-18 VDC
20-30 VDC
4.5-6 VDC
12-18 VDC
20-30 VDC
Output supply current at rated
input voltage (see note 2)
18 mA max.
15 mA max.
12 mA max.
18 mA max.
15 mA max.
12 mA max.
Control resistance (Rc in circuit
configuration - see note 1)
240 Ω
1 kΩ
2.2 kΩ
240 Ω
1k Ω
2.2k Ω
Output current
50 mA max.
Characteristics
Item
G3TC-IAC5
Operate time (see note 3)
20 ms max.
Release time (see note 3)
20 ms max.
Output ON voltage drop
0.4 V max.
Leakage current
100 μA max.
Weight
Approx. 40g
G3TC-IAC15
G3TC-IAC24
G3TC-IAC5A
G3TC-IAC15A
G3TC-IAC24A
Note: 1. Resistance values are reference.
2. The input module supplies the current on I/O circuit board at nominal ouput voltage.
3. At nominal output supply voltage, rated input voltage and 25°C.
■ DC Input Module G3TC-IDC
Ratings (Ambient Temperature 25°C)
Input
Item
G3TC-IDC5
Rated voltage
24 VDC/AC
Operating voltage
10-32 VDC/ 15-32 VAC
Must operate voltage
10 VDC/15 VAC max.
Must release voltage
3 VDC/ 3 VAC min.
Input current rated voltage
25 mA max.
Input resistance (see note 1)
1.5 kΩ
G3TC-IDC15
G3TC-IDC24
Output
Item
G3TC-IDC5
G3TC-IDC15
15 VDC
G3TC-IDC24
Output supply voltage-nominal
5 VDC
Output supply voltage-range
4.5-6 VDC
12-18 VDC
20-30 VDC
Output supply current at rated input voltage (see note 2)
18 mA max.
15 mA max.
12 mA max.
1 kΩ
2.2 kΩ
Control resistance (Rc in circuit configuration - see note 1) 240 Ω
Output current
24 VDC
50 mA max.
Solid State Relays for Industrial I/O
G3TC
397
Characteristics
Item
G3TC-IDC5
Operate time (see note 3)
5 ms max.
Release time (see note 3)
5 ms max.
Output ON voltage drop
0.4 V max.
Leakage current
100 μA max.
Weight
Approx. 40g
G3TC-IDC15
G3TC-IDC24
Note: 1. Resistance values are reference.
2. The input module supplies the current on I/O circuit board at nominal ouput voltage.
3. At nominal output supply voltage, rated input voltage and 25°C.
■ AC Output Module G3TC-OAC
Ratings (Ambient Temperature 25°C)
Input
Item
G3TC-OAC5
G3TC-OAC15
G3TC-OAC24
G3TC-OAC5A
G3TC-OAC15A
G3TC-OAC24A
Rated voltage
5 VDC
15 VDC
24 VDC
5 VDC
15 VDC
Operating voltage
2.5-8 VDC
9-16 VDC
18-32 VDC
2.5-8 VDC
9-16 VDC
18-32 VDC
Must operate
voltage
2.5 VDC max.
9 VDC max.
18 VDC max.
2.5 VDC max.
9 VDC max.
18 VDC max.
Must release
voltage
1 VDC min.
Input current at rated
voltage (see note 2)
18 mA max.
1 kΩ
2.2 kΩ
240 Ω
1 kΩ
2.2 kΩ
Control resistance (Rc 240 Ω
in circuit configuration
- see note 1)
24 VDC
Output
Item
G3TC-OAC5
G3TC-OAC15
G3TC-OAC24
G3TC-OAC5A
Rated load voltage
120 VAC
240 VAC
Load voltage range
75-140 VAC
75-280 VAC
Load current
0.05 to 3 A
Inrush current
45 A (60 Hz, 1 cycle)
G3TC-OAC15A
G3TC-OAC24A
Characteristics
Item
G3TC-OAC5
G3TC-OAC15
G3TC-OAC24
Operate time (see note 3)
1/2 of load power source cycle + 1 ms max.
Release time (see note 3)
1/2 of load power source cycle + 1 ms max.
Output ON voltage drop
1.6 V (RMS) max.
Leakage current
2.5 mA max. (at 120 VAC)
Weight
Approx. 45g
G3TC-OAC5A
5 mA max. (at 240 VAC)
Note: 1. Resistance values are reference.
2. The output module supplies the current on I/O circuit board at nominal input voltage.
3. At nominal output supply voltage, rated input voltage and 25°C.
398
Solid State Relays for Industrial I/O
G3TC-OAC15A
G3TC
G3TC-OAC24A
■ DC Output Module G3TC-ODC
Ratings (Ambient Temperature 25°C)
Input
Item
G3TC-ODC5
G3TC-ODC15
G3TC-ODC24
5 VDC
G3TC-ODC15A
15 VDC
G3TC-ODC24A
5 VDC
15 VDC
Operating voltage
2.5-8 VDC
9-16 VDC
18-32 VDC
2.5-8 VDC
9-16 VDC
18-32 VDC
Must operate
voltage
2.5 VDC max.
9 VDC max.
18 VDC max.
2.5 VDC max.
9 VDC max.
18 VDC max.
Must release
voltage
1 VDC min.
Input current at rated
voltage (see note 2)
18 mA max.
1 kΩ
2.2 kΩ
240 Ω
1 kΩ
2.2 kΩ
Control resistance (Rc 240 Ω
in circuit configuration
- see note 1)
24 VDC
G3TC-ODC5A
Rated voltage
24 VDC
Output
Item
G3TC-ODC5
G3TC-ODC15
G3TC-ODC24
G3TC-ODC5A
Rated load voltage
60 VDC
200 VDC
Load voltage range
5-60 VDC
5-200 VDC
Load current
0.01 to 3 A
0.01 to 1.0 A
Inrush current
18 A (10 ms)
9 A (10 ms)
G3TC-ODC15A
G3TC-ODC24A
Characteristics
Item
G3TC-ODC5
G3TC-ODC15
G3TC-ODC24
G3TC-ODC5A
G3TC-ODC15A
Operate time (see note 3)
50 μs max.
100 μs max.
Release time (see note 3)
50 μs max. (see note 4)
750 μs max.
Output ON voltage drop
1.6 V max.
Leakage current
1 mA max. (at 60 VDC)
1 mA max. (at 200 VDC)
Weight
Approx. 45g
Approx. 40g
Note: 1.
2.
3.
4.
G3TC-ODC24A
Resistance values are reference.
The output module supplies the current on I/O circuit board at nominal input voltage.
At rated load voltage, maximum rated load current, rated input voltage and 25°C.
At 24 VDC load voltage, 3 A load current and 25°C.
Solid State Relays for Industrial I/O
G3TC
399
Engineering Data
■ Internal Circuit
G3TC-IAC/IDC
G3TC-OAC
AC Output
AC/DC Input
In
Out
-
Out
In
-
-
Note: Internal biasing circuitry is different between AC input and DC
input modules
G3TC-ODC
DC Output
Out
-
In
-
400
Solid State Relays for Industrial I/O
G3TC
■ Load Current vs. Ambient Temperature Characteristics
G3TC-ODC5A
G3TC-ODC15A
G3TC-ODC24A
2
3
1.5
2
1.6
1
G3TC-OAC5A
G3TC-OAC15A
G3TC-OAC24A
G3TC-OAC5
G3TC-OAC15
G3TC-OAC24
4
Load current (A)
4
Load current (A)
Load current (A)
G3TC-ODC5
G3TC-ODC15
G3TC-ODC24
1
0.55
0.5
3
2
1.6
1
0.37
0
−30 −20
0
20
40 45
60 70 80
100
0
−30 −20
Ambient temperature (°C)
0
20
40 45
60 70 80
100
0
−30 −20
0
20
40 45
60 70 80
100
Ambient temperature (°C)
Ambient temperature (°C)
■ Inrush Current Resitivity
Non-repetitive (Keep inrush current to half the rated value if it occurs.)
15
28
14
26
13
24
22
20
18
16
14
12
10
8
6
12
11
10
9
8
7
6
5
4
3
4
2
2
1
0
0
20 30
50 70 100
200 300 500
Energized time (ms)
1,000 2,000
50
Inrush current (A. Peak)
30
G3TC-OAC5A
G3TC-OAC15A
G3TC-OAC24A
G3TC-OAC5
G3TC-OAC15
G3TC-OAC24
G3TC-ODC5A
G3TC-ODC15A
G3TC-ODC24A
Inrush current (A. Peak)
Inrush current (A. Peak)
G3TC-ODC5
G3TC-ODC15
G3TC-ODC24
40
30
20
10
0
0
0
30
50
100
300 500
Energized time (ms)
1,000 2,000
10
30 50
100
200
500 1,000
5,000
Energized time (ms)
Solid State Relays for Industrial I/O
G3TC
401
Dimensions
G3TC-IAC5 G3TC-IAC5A
G3TC-IAC15 G3TC-IAC15A
G3TC-IAC24 G3TC-IAC24A
15.2
Note: All units are in millimeters unless otherwise indicated.
2.5
43.2
#4–40 Hold down screw
31.8
25.4
5
4
3
2
1
6.0
7.6
1.0 dia.
7.6
10.16
22.86
27.94
G3TC-IDC5
G3TC-IDC15
G3TC-IDC24
15.2
33.02
2.5
43.2
#4–40 Hold down screw
31.8
25.4
5
4
3
2
1
6.0
7.6
1.0 dia.
7.6
10.16
22.86
27.94
G3TC-OAC5 G3TC-OAC5A
G3TC-OAC15 G3TC-OAC15A
G3TC-OAC24 G3TC-OAC24A
15.2
33.02
(2.5)
43.2
#4–40 Hold down screw
31.8
25.4
4
3
2
1
6.0
7.6
10.16
22.86
27.94
402
Solid State Relays for Industrial I/O
G3TC
1.0 dia.
7.6
15.2
G3TC-ODC5 G3TC-ODC5A
G3TC-ODC15 G3TC-ODC15A
G3TC-ODC24 G3TC-ODC24A
2.5
43.2
#4–40 Hold down screw
31.8
25.4
4
3
2
1
6.0
7.6
1.0 dia.
10.16
7.6
22.86
27.94
■ Approvals
UL Recognized (File No. E64562) / CSA Certified (File No. 35535) - - Ambient Temp. = 40°C
Input
Output
Model
Input voltage
Model
Load voltage Load current
G3TC-IAC5, -IAC15, -IAC24
90-140 V AC/DC
G3TC-IAC5, -IAC15, -IAC24
5/15/24 VDC
50 mA
G3TC-IAC5A, -IAC15A, -IAC24A
180-280 V AC/DC
G3TC-IAC5A, -IAC15A, -IAC24A
5/15/24 VDC
50 mA
G3TC-IDC5, -IDC15, -IDC24
10-32 VDC, 12-32 VAC
G3TC-IDC5, -IDC15, -IDC24
5/15/24 VDC
50 mA
G3TC-ODC5, -ODC5A, -OAC5, -OAC5A
5 VDC
G3TC-ODC5, -ODC15, -ODC24
5-60 VDC
3A
G3TC-ODC15, -ODC15A, -OAC15,
-OAC15A
15 VDC
G3TC-ODC5A, -ODC15A,
-ODC24A
5-200 VDC
1A
G3TC-ODC24, -ODC24A, -OAC24,
-OAC24A
24 VDC
G3TC-OAC5, -OAC15, -OAC24
75-140 VAC
3A
G3TC-OAC5A, -OAC15A, -OAC24A 75-280 VAC
3A
Note: The rated values approved by each of the safety standards (e.g., UL, CSA and TUV) may be different from the performance characteristics
individually defined in this catalog.
Solid State Relays for Industrial I/O
G3TC
403
Precautions
!WARNING
Do not touch the relay while power is supplied or immediately after
G3TC is turned OFF. Doing so may result in burns.
!WARNING
Do not touch the load terminal of the G3TC immediately after the
power is turned OFF, otherwise an electric shock may be received
due to the residual charge of the built-in C/R circuit.
9. For a DC inductive load, a diode should be connected in parallel
with the load to absorb the counter electromotive force of the
load.
10.For an I/O mounting rack that is installed horizontally, use the
G3TC with loads that are within the following conditions.
G3TC-OAC5, -OAC5A, -OAC15, -OAC15A, -OAC24, -OAC24A
Horizontal Mounting
4
!WARNING
Ensure that a short-circuit current does not flow on the load side of
the SSR, otherwise the G3TC may be damaged.
Load current (A)
!WARNING
Be sure to turn OFF the power supply to the G3TC before wiring,
otherwise an electric shock may result.
3
2.1
2
1
■ General Precautions
0.64
1. Do not apply excessive voltage or current to the input or output
circuit of the G3TC. Doing so may result in malfunction or burning.
2. Do not connect the input and output circuits incorrectly. Doing so
may result in malfunction or burning.
3. Do not obstruct the flow of air around the G3TC. Abnormal heating of the G3TC may result in short-circuiting of output elements
and burning.
■ Correct Use
0
−30 −20
0
20
40 45
60 70 80
100
Ambient temperature (°C)
G3TC-ODC5, -ODC15, -ODC24
Horizontal Mounting
4
Load current (A)
At OMRON, we are constantly working to improve the quality and
reliability of our products. SSRs, however, use semiconductors,
which are prone to malfunction. Be sure to use SSRs within their
rated value. Use the SSR only in systems that are designed with
redundancies, flame protection, counter measures to prevent operation errors, and other countermeasures to prevent accidents involving human life or fires.
3
2.7
2
1
0.64
Before Actual Operation
1. In actual operation, the G3TC may cause accidents that were
unforeseeable at the theoretical stage. Therefore, it is necessary
to test the G3TC under a variety of conditions that are possible.
As for the characteristics of the G3TC, it is necessary to consider
the differences between G3TC models.
2. The ratings in this datasheet are for testing in a temperature
range of 15 to 30°C, a relative humidity range of 25% to 85%, and
an atmospheric pressure range of 88 to 106kPa. When testing
operation, it is necessary to confirm correct operation not only
with the actual load that will be used, but also at the same ambient conditions as for actual operation.
3. The input circuitry does not incorporate a circuit protecting the
SSR from being damaged due to a reversed connection. Make
sure that the polarity is correct when connecting the input lines.
4. Only use the G3TC with loads that are within the rated values.
Using the G3TC with loads outside the rated values may result in
malfunction, damage, or burning.
5. Use a power supply within the rated frequency range. Using a
power supply outside the rated frequency range may result in
malfunction, damage, or burning.
6. No over-voltage absorption element is built in. Therefore, if the
G3TC is connected to an inductive load, be sure to connect an
over-voltage absorption element.
7. As protection against accidents due to short-circuiting, be sure to
install protective devices, such as fuses on the power supply side.
8. Keep wiring separate from high-voltage power lines and use wires
of an appropriate length, otherwise malfunction and damage may
result due to induction.
404
Solid State Relays for Industrial I/O
G3TC
0
−30 −20
0
20
40 45
60 70 80
Ambient temperature (°C)
100
■ Operating and Storage Environments
Operating Ambient Temperature
The rated value for the ambient operating temperature of the G3TC
is for when there is no built-up heat. For this, reason, under conditions where heat dissipation is not good due to poor ventilation, and
where heat may build up easily, the actual temperature of the G3TC
may exceed the rated value resulting in malfunction or burning.
When using the G3TC, design the system to allow heat dissipation
sufficient to stay below the Load Current vs. Ambient Temperature
characteristic curve. Note also that the ambient temperature of the
G3TC may increase as a result of environmental conditions (e.g., climate, air-conditioning) and operating conditions (e.g., mounting in an
airtight panel).
Operating and Storage Locations
Do not use or store the G3TC in the following locations. Doing so
may result in damage, malfunction, or deterioration of performance
characteristics.
1. Do not use or store in locations subject to direct sunlight.
2. Do not use in locations subject to ambient temperatures outside
the range -30° to 80°C.
3. Do not use in locations subject to relative humidity outside the
range 45% to 85% or locations subject to condensation as the
result of severe change in temperature.
4. Do not store in locations subject to ambient temperatures outside
the range -30° to 100°C.
5. Do not use or store in locations subject to corrosive or flammable
gases.
6. Do not use or store in locations subject to dust (especially iron
dust) or salts.
7. Do not use or store in locations subject to shock or vibration.
8. Do not use or store in locations subject to exposure to water, oil,
or chemicals.
Transportation
When transporting the G3TC, observe the following points. Not doing
so may result in damage, malfunction, or deterioration of performance characteristics.
1. Do not drop the G3TC or subject it to severe vibrations or shock.
2. Do not transport the product if it is wet.
Vibration and Shock
Do not subject the SSR to excessive vibration or shock. Otherwise
the SSR may malfunction and internal components may be damaged.
Solid State Relays for Industrial I/O
G3TC
405
MEMO
406
Solid State Relays for Industrial I/O
G3TC
Omron Electronic Components, LLC
Terms and Conditions of Sales
I. GENERAL
1. Definitions: The words used herein are defined as follows.
(a) Terms:
These terms and conditions
(b) Seller:
Omron Electronic Components LLC and its subsidiaries
(c) Buyer:
The buyer of Products, including any end user in section III through VI
(d) Products: Products and/or services of Seller
(e) Including: Including without limitation
2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments,
invoices, purchase orders and other documents, whether electronic or in writing, relating
to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's
purchase order or other documents which are inconsistent with, or in addition to, these
Terms.
3. Distributor: Any distributor shall inform its customer of the contents after and including
section III of these Terms.
II. SALES
1. Prices; Payment: All prices stated are current, subject to change without notice by Seller.
Buyer agrees to pay the price in effect at the time the purchase order is accepted by
Seller. Payments for Products received are due net 30 days unless otherwise stated in
the invoice. Buyer shall have no right to set off any amounts against the amount owing in
respect of this invoice.
2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to
Buyer after deducting transportation charges, taxes and duties, and will be allowed only
if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past
due amounts owing to Seller.
3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum
legal rate, whichever is less, on any balance not paid within the stated terms.
4. Orders: Seller will accept no order less than 200 U.S. dollars net billing.
5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer
shall make remittance to Seller at the then current exchange rate most favorable to
Seller; provided that if remittance is not made when due, Buyer will convert the amount
to U.S. dollars at the then current exchange rate most favorable to Seller available
during the period between the due date and the date remittance is actually made.
6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining
any government approvals regarding the importation or sale of the Products.
7. Taxes: All taxes, duties and other governmental charges (other than general real
property and income taxes), including any interest or penalties thereon, imposed directly
or indirectly on Seller or required to be collected directly or indirectly by Seller for the
manufacture, production, sale, delivery, importation, consumption or use of the Products
sold hereunder (including customs duties and sales, excise, use, turnover and license
taxes) shall be charged to and remitted by Buyer to Seller.
8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller,
Seller reserves the right to stop shipments or require satisfactory security or payment in
advance. If Buyer fails to make payment or otherwise comply with these Terms or any
related agreement, Seller may (without liability and in addition to other remedies) cancel
any unshipped portion of Products sold hereunder and stop any Products in transit until
Buyer pays all amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid
accounts.
9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer
indemnifies Seller fully against all costs or expenses arising in connection therewith.
10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from
causes beyond its control, including earthquakes, fires, floods, strikes or other labor
disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots,
delay in or lack of transportation or the requirements of any government authority.
11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller:
(a) All sales and shipments of Products shall be FOB shipping point (unless otherwise
stated in writing by Seller), at which point title to and all risk of loss of the Products
shall pass from Seller to Buyer, provided that Seller shall retain a security interest in
the Products until the full purchase price is paid by Buyer;
(b) Delivery and shipping dates are estimates only; and
(c) Seller will package Products as it deems proper for protection against normal
handling and extra charges apply to special conditions.
12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products
occurring before delivery to the carrier or any claim related to pricing or other charges
must be presented in detail in writing to Seller within 30 days of receipt of shipment.
III. PRECAUTIONS
1. Suitability: IT IS THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY
OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE
APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING
APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE
BUYER’S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC
COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E)
SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT.
Buyer acknowledges that it alone has determined that the Products will meet their
requirements of the intended use in all cases. Buyer must know and observe all
prohibitions of use applicable to the Product/s.
2. Use with Attention: The followings are some examples of applications for which
particular attention must be given. This is not intended to be an exhaustive list of all
possible use of any Product, nor to imply that any use listed may be suitable for any
Product:
(a) Outdoor use, use involving potential chemical contamination or electrical
interference.
(b) Use in consumer Products or any use in significant quantities.
(c) Energy control systems, combustion systems, railroad systems, aviation systems,
medical equipment, amusement machines, vehicles, safety equipment, and
installations subject to separate industry or government regulations.
(d) Systems, machines, and equipment that could present a risk to life or property.
3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE
PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED
VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY
SELLER.
5. Programmable Products: Seller shall not be responsible for the Buyer's programming of
a programmable Product.
IV. WARRANTY AND LIMITATION
1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in
materials and workmanship for a period of twelve months from the date of sale by Seller
(or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY
OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES,
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE OF THE PRODUCTS.
2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form
originally shipped with Buyer responsible for labor charges for removal or replacement
thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an
amount equal to the purchase price of the Product; provided that there shall be no
liability for Seller or its affiliates unless Seller's analysis confirms that the Products were
correctly handled, stored, installed and maintained and not subject to contamination,
abuse, misuse or inappropriate modification. Return of any Products by Buyer must be
approved in writing by Seller before shipment.
3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF
PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED
WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT,
WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL
LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF
THE PRODUCT ON WHICH LIABILITY IS ASSERTED.
4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its
employees from and against all liabilities, losses, claims, costs and expenses (including
attorney's fees and expenses) related to any claim, investigation, litigation or proceeding
(whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or
omissions under these Terms or in any way with respect to the Products.
V. INFORMATION; ETC.
1. Intellectual Property: The intellectual property embodied in the Products is the exclusive
property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way
without the written permission of Seller. Buyer (at its own expense) shall indemnify and
hold harmless Seller and defend or settle any action brought against Seller to the extent
that it is based on a claim that any Product made to Buyer specifications infringed
intellectual property rights of another party.
2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or
tooling, all engineering and tooling shall remain the exclusive property of Seller. All
information and materials supplied by Seller to Buyer relating to the Products are
confidential and proprietary, and Buyer shall limit distribution thereof to its trusted
employees and strictly prevent disclosure to any third party.
3. Performance Data: Performance data is provided as a guide in determining suitability
and does not constitute a warranty. It may represent the result of Seller's test conditions,
and the users must correlate it to actual application requirements.
4. Change In Specifications: Product specifications and descriptions may be changed at
any time based on improvements or other reasons. It is Seller’s practice to change part
numbers when published ratings or features are changed, or when significant
engineering changes are made. However, some specifications of the Product may be
changed without any notice.
5. Errors And Omissions: The information on Seller’s website or in other documentation
has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses
regarding (a) export of the Products or information provided by Seller; (b) sale of
Products to forbidden or other proscribed persons or organizations; (c) disclosure to noncitizens of regulated technology or information.
VI. MISCELLANEOUS
1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing
between Buyer and Seller shall operate as a waiver of rights by Seller.
2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent.
3. Law: These Terms are governed by Illinois law (without regard to conflict of laws).
Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any
dispute hereunder.
4. Amendment: These Terms constitute the entire agreement between Buyer and Seller
relating to the Products, and no provision may be changed or waived unless in writing
signed by the parties.
5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall
not invalidate any other provision.
Solid State Relays for Industrial I/O
G3TC
Certain Precautions on Specifications and Use
1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in
Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use.
Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer
shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government
regulations.
(iii) Use in consumer products or any use in significant quantities.
(iv) Systems, machines and equipment that could present a risk to life or
property. Please know and observe all prohibitions of use applicable to this
product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT
THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
3. Performance Data. Performance data given in this publication is provided as
a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must
correlate it to actual application requirements. Actual performance is subject to
Seller's Warranty and Limitations of Liability.
4. Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Seller representative at any time to
confirm actual specifications of purchased Product.
5. Errors and Omissions. The information in this publication has been carefully
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors, or omissions.
6. RoHS Compliance. Where indicated, our products currently comply, to the
best of our knowledge as of the date of this publication, with the requirements
of the European Union's Directive on the Restriction of certain Hazardous
Substances ("RoHS"), although the requirements of RoHS do not take effect
until July 2006. These requirements may be subject to change. Please consult
our website for current information.
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X301-E-1
06/09
Specifications subject to change without notice