ETC2 LEA50F-30 Harmonic attenuator, pfc (complies with iec61000-3-2) Datasheet

Home > Product Details
LEA50F
Features
Harmonic attenuator, PFC (Complies with IEC61000-3-2)
Universal input (AC85-264V)
Remote ON/OFF Control (Optional)
Rugged PCB type
RoHS Compliant
Safety Agency Approvals
Complies with DEN-AN
UL1950, C-UL recognized, TUV approved
EMI Compliance
FCC-B
CISPR22-B
EN55022-B
VCCI-B
Input
Voltage
[V]
Output
Wattage
[W]
DC
Output
[V/A]
LEA50F-3R3Y
DC 120 370
AC 85 - 264
33
3.3V
10A
LEA50F-5
DC 120 370
AC 85 - 264
50
5V
10A
LEA50F-9
DC 120 370
AC 85 - 264
50.4
9V
5.6A
LEA50F-12
DC 120 370
AC 85 - 264
51.6
12V
4.3A
LEA50F-15
DC 120 370
AC 85 - 264
52.5
15V
3.5A
LEA50F-18
DC 120 370
AC 85 - 264
50.4
18V
2.8A
LEA50F-24
DC 120 370
AC 85 - 264
50.4
24V
2.1A
LEA50F-24-H
DC 120 370
AC 85 - 264
50.4
24V
(peak 62.4V)
2.1A
(peak 2.6A)
LEA50F-30
DC 120 370
AC 85 - 264
51
30V
1.7A
LEA50F-48
DC 120 370
AC 85 - 264
52.8
48V
1.1A
Model
CE Markings
Low Voltage Directive
EMC Directive
EMC Compliance
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
EN61000-3-2
2 year warranty(refer to Instruction Manual)
Ordering information
Rugged PCB type
LEA50F
LEA
1
50
2
F
3
-5
Recommended Noise Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
*5
LEA50F-3R3-Y LEA50F-5
33
50
3.3V 10A
5V 10A
LEA50F-9
50.4
9V 5.6A
-O
4
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
J2:Mini terminal block
R :with Remote ON/OFF
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
LEA50F-12 LEA50F-15 LEA50F-18 LEA50F-24 LEA50F-24-H LEA50F-30 LEA50F-48
51.6
52.5
50.4
50.4
50.4
51
52.8
12V 4.3A
15V 3.5A
18V 2.8A
24V 2.1A
24V 2.1(2.6)A 30V 1.7A
48V 1.1A
SPECIFICATIONS
MODEL
VOLTAGE[V]
LEA
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*1
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *2
RIPPLE[mVp-p]
-10 - 0C *2
0 to +50C *2
RIPPLE NOISE[mVp-p]
-10 - 0C *2
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
DRIFT[mV]
*3
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT -RC
*4
INPUT-FG
OUTPUT-RC-FG
*4
OUTPUT-RC
*4
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
LEA50F-3R3-Y LEA50F-5 LEA50F-9 LEA50F-12 LEA50F-15 LEA50F-18 LEA50F-24 LEA50F-24-H
AC85 - 264 1f or DC120 - 370
0.6
0.7typ
0.3
0.35typ
50/60 (47 - 63) or DC
70typ
75typ
78typ
78typ
79typ
80typ
81typ
81typ
71typ
77typ
80typ
80typ
81typ
82typ
83typ
83typ
0.98typ
0.99typ
0.91typ
0.93typ
15typ (Io=100%) (At cold start) (Ta=25 C)
30typ (Io=100%) (At cold start) (Ta=25 C)
0.75max (60Hz, According to IEC60950 and DEN-AN)
3.3
5
9
12
15
18
24
24
10
10
5.6
4.3
3.5
2.8
2.1
2.1 (Peak 2.6)
20max
20max
36max
48max
60max
72max
96max
96max
40max
40max
100max
100max
120max
120max
150max
150max
80max
80max
120max
120max
120max
120max
120max
120max
140max
140max
160max
160max
160max
160max
160max
160max
120max
120max
150max
150max
150max
150max
150max
150max
160max
160max
180max
180max
180max
180max
180max
180max
50max
50max
90max
120max
150max
180max
240max
240max
60max
60max
120max
150max
180max
200max
290max
290max
20max
20max
36max
48max
60max
72max
96max
96max
500max (ACIN 100V, Io=100%)
20typ (Io=100%)
2.85 - 3.6
Fixed ("Y"which can be adjusted the output is available as optional:t10%)
3.25 - 3.35 4.9 - 5.3
8.6 - 9.4
11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0
Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically
4.00 - 5.25V Works at 115 - 140% of rating
Not provided
Not provided
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2
55X26X195mm (WXHXD) /210g max (without chassis and cover)
Convection
*1 Peak load for 10sec. or less is acceptable if the total wattage is less than the rated wattage.
*2 This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:
RM101).
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
E-18
*4
*5
*
*
with the input voltage held constant at the rated input/output.
Applicable when remote control (optional) is added.
( ):peak current.
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
LEA50F-30 LEA50F-48
82typ
84typ
83typ
85typ
30
1.7
120max
180max
120max
160max
150max
180max
300max
360max
120max
48
1.1
192max
300max
150max
200max
350max
400max
480max
600max
192max
28.5 - 31.5 46.0 - 50.0
LEA50F
External view
Output(-)
Output(+)
C119
Connector for Remote
ON/OFF (optional)
CN3
CN2
4-M3
Mounting Hole
CN1
5
CN2
7
210-+0.5
3.5
32
65
55
RC(-)
RC(+)
FG
AC(N)
AC(L)
45-+0.5
17.5
CN3
CN1
2-º3.5
4-º3.5
Mounting
Hole
Name plate
40 -+0.5 12
20 -+0.5 22
23
Voltage adjust (optional)
185-+0.5
195
5
225
210-+0.5
3.5
7
15 10
36
2-M3
Mounting Hole
(Lead)
3max
23
º3.5
PCB t=1.6
PIN CONNECTION
I / O Connector Mating Connector
VHR-5N
CN1 B3P5-VH
CN2 B4P-VH
VHR-4N
CN3 B2B-XH-A
XHP-2
Terminal
Chain : SVH-21T-P1.1
Loose: BVH-21T-P1.1
Chain : SVH-21T-P1.1
Loose: BVH-21T-P1.1
Chain : SXH-001T-P0.6
Loose: BXH-001T-P0.6
(Mfr: J.S.T.)
¶Weight: 210g or less
(Without chassis and cover)
¶Tolerance: t1
¶Dimensions in mm.
¶PCB Material: Glass composite
(CEM3)
¶Chassis and cover is optional.
¶Mounting torque: 0.6N · m(6.3kg f · cm)max
Optional
Pin No. Input
1
AC(L)
2
CN1
3
AC(N)
4
5
FG
Pin No. Output
CN2
1
-V
2
-V
3
+V
4
+V
Pin No. Remote ON/OFF
1
RC(+)
2
RC(-)
CN3
¶Keep drawing current per pin below 5A for CN2
Performance data
¡RISE TIME & FALL TIME (LEA50F-5)
¡EFFICIENCY (LEA50F-5)
80
78
DC Output
ACIN 100V Io=100%
AC Input
EFFICIENCY
76
74
72
Load factor100%
Load factor 50%
70
68
60
50ms/DIV
¡INPUT HARMONIC CURRENT (LEA50F-5)
140
180
220
INPUT VOLTAGE
260
300
V
¡INPUT HARMONIC CURRENT (LEA50F-5)
10
10
HARMONIC CURRENT
Load factor
100%
Input voltage AC 100V
1
Harmonic current standard class A
(at odd number)
A
Harmonic current standard class A
(at odd number)
A
HARMONIC CURRENT
100
0.1
0.01
1
100%
Load factor
Input voltage AC 230V
0.1
0.01
0.001
0.001
0
10
20
HARMONIC ORDER
30
40
0
10
20
30
40
HARMONIC ORDER
E-19