MPD MA3110DMRW-12RI4 En 60601 approved 4:1 input, 3w dip, dc/dc con vert er Datasheet

MA300MRURI4
EN 60601 Approved
4:1 Input, 3W DIP,
DC/DC Converters
Key Features:
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• EN 60601 3RD Ed. Approved
Input
• 3W Output Power
Parameter
• 4.0 kVrms Isolation
• Reinforced Insulation
• 1 x MOPP & 2xMOOP per
EN 60601-1 3RD Edition &
ANSI/AAMI ES 60601-1
• 2 µA Leakage Current Max
• Wide 4:1 Input Range
• Compact 24 Pin DIP Case
• 110 VDC Input Models
• 1.0 MH MTBF
Input Start Voltage
Under Voltage Shutdown
Input Filter
Short Circuit Input Power
Conditions
Min.
24 VDC Input
8.0
48 VDC Input 13.0
110 VDC Input 26.0
24 VDC Input
48 VDC Input
110 VDC Input
␲ (Pi) Filter
Typ.
8.5
15.0
30.0
Max.
9.0
17.0
34.0
8.5
16.0
32.0
Units
2,000
mW
Max.
±1.0
±2.0
±0.5
±1.0
100
150
Units
%
%
%
%
VDC
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Conditions
Ripple & Noise (20 MHz), See Note 2
Output Power Protection
Transient Recovery Time, See Note 3
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Min.
Typ.
Dual Output , Balanced Loads
VIN = Min to Max
IOUT = 25% to 100%
5V Output Models
All Other Models
±0.5
±0.3
±0.5
75
100
120
150
150
25% Load Step Change
±3.0
±0.02
Continuous (Autorecovery)
500
±6.0
±0.05
mV P - P
%
µSec
%
%/ºC
General
Parameter
Isolation Voltage
Reinforced Insulation Working Voltage
Leakage Current
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
Min.
60 Seconds 4,000
1,000 Vrms
240 VAC, 60 Hz
500 VDC
10
100 kHz, 1V
Typ.
7
150
Max.
Units
Vrms
2
µA
G⍀
pF
kHz
13
EMI Characteristics
Parameter
EMC
EMS
Standard
Criteria
Complies With EN 55011 4TH Edition
Complies With EN 60601-1-2
Level
Environmental
Parameter
Conditions
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Ambient
Case
Min.
-40
Typ.
+25
-50
Free Air Convection
RH, Non-condensing
Max.
+85
+100
+125
Units
95
%
°C
Physical
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Case Size
Case Material
Weight
See Mechanical Diagram (Page 3)
Non-Conductive Black Plastic (UL94-V0)
0.58 Oz (16.6g)
Reliability Specifications
Parameter
MTBF
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25ºC, Gnd Benign
1.0
MHours
IEC/EN 60601-1 3RD Edition, 1XMOPP & 2xMOOP
ANSI/AAMI ES 60601-1 1xMOPP & 2xMOOP Recognition (UL Certificate)
ANSI/AAMI ES 60601-1, CAN/CSA-C22.2 No.60601-1
Safety Standards
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1.0 Sec)
Lead Temperature
Conditions
24 VDC Input
48 VDC Input
110 VDC Input
1.5 mm From Case For 10 Sec
Min.
Typ.
Max.
50.0
100.0
180.0
260
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
ºC
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Output
Voltage (VDC)
Current (mA)
Full-Load No-Load
Capacitive
Load
Fuse Rating
Slow-Blow
(µF Max)
(mA)
78
1,000
1,100
Efficiency
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
5.0
600
90.0
(%, Typ)
Nominal
Range
MA324SMRU-05RI4
24
9.0 - 40.0
160
20
MA324SMRU-12RI4
24
9.0 - 40.0
151
20
12.0
250
37.5
83
470
1,100
MA324DMRU-12RI4
24
9.0 - 40.0
151
20
±12.0
±125
±18.8
83
220
1,100
MA324DMRU-15RI4
24
9.0 - 40.0
151
29
±15.0
±100
±15.0
83
220
1,100
MA348SMRU-05RI4
48
18.0 - 80.0
80
10
5.0
600
90.0
78
1,000
500
MA348SMRU-12RI4
48
18.0 - 80.0
75
10
12.0
250
37.5
83
470
500
MA348DMRU-12RI4
48
18.0 - 80.0
75
10
±12.0
±125
±18.8
83
220
500
MA348DMRU-15RI4
48
18.0 - 80.0
75
10
±15.0
±100
±15.0
83
220
500
MA3110SMRU-05RI4
110
36.0 - 160.0
35
5
5.0
600
90.0
78
1,000
250
MA3110SMRU-12RI4
110
36.0 - 160.0
33
5
12.0
250
37.5
83
470
250
MA3110DMRW-12RI4
110
36.0 - 160.0
33
5
±12.0
±125
±18.8
83
220
250
MA3110DMRW-15RI4
110
36.0 - 160.0
33
5
±15.0
±100
±15.0
83
220
250
Notes:
1. The specified maximum capacitive load is for each output.
2. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be
placed from the +VOUT pin to the -VOUT pin for single output units and from each output to common
for dual output units.
3. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
4. Dual output units may be connected to provide a 24 VDC or 30 VDC output. To do this, connect
the load across the positive (+VOUT) and negative (-VOUT) outputs and float the output common.
5. The converter should be connected to a low ac-impedance source. An input source with a highly
inductive impedance may affect the stability of the converter. In applications where the converter
output loading is high and input power is supplied over long lines, it may be necessary to use a
capacitor on the input to insure start-up. The size of the recommended capacitor is given below.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the
table above for the correct rating.
Typical Connection/ Single Output
Typical Connection/ Dual Output
These converters are specified for operation without external components. However, in some applications the addition of input/output capacitors, as shown in the typical
connection diagram above, will enhance stability and reduce output ripple. This simple connection includes a low ESR (<1ม at 100 kHz) capacitor connected across the input
(C1). It is recommended that a 4.7 µF be used for 24V input models, a 2.2 µF for 48V models and 1.0 µF for 100V input units. To improve the output ripple performance, a
3.3 µF is connected across the output. For dual output units, a 3.3 µF capacitor should be connected from each output to common.
Page 2
We Power Your Success - For Less
www.micropowerdirect.com
Temperature Derating, 400 LFM
Temperature Derating, 20LFM (Ambient Air)
Mechanical Dimensions
Pin Connections
Pin
1
11
12
13
15
23
24
Single
+VIN
No Pin
-VOUT
+VOUT
No Pin
-VIN
-VIN
Dual
+VIN
Common
No Pin
-VOUT
+VOUT
-VIN
-VIN
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Medical Approved Power Products
Thousands of standard power products ranging from 0.5W to 500W are available from MPD in
a wide variety of packages and pin-outs. This includes many more DC/DC and AC/DC product
families with EN 60601 medical approval. Go to micropowerdirect.com for full information.
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages