FEATURES:
•
•
•
•
I/O Isolation 3000VAC
Operating Temp: -25 °C to +70 °C
Input: 85-264VAC, 47-63Hz, or 120-370VDC
Over current, Over Voltage Protection
•
•
•
•
Continuous Short circuit protection
Energy Star compliant
Compact package
Efficiency up to 82%
Models
Single output
Model
AME5-3.3SCJZ
AME5-5SCJZ
AME5-9SCJZ
AME5-12SCJZ
AME5-15SCJZ
AME5-24SCJZ
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
120-370
120-370
120-370
120-370
120-370
120-370
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
120-370
120-370
120-370
120-370
Output
Voltage
(V)
3.3
5
9
12
15
24
Output
Current max
(A)
1.25
1
0.55
0.42
0.330
0.23
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
8100
6800
1200
1000
680
270
70
75
77
79
80
82
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
±1480
±130
±110
±16
75
79
79
80
Models
Dual output
Model
AME5-5DCJZ
AME5-12DCJZ
AME5-15DCJZ
AME5-24DCJZ
Output
Voltage
(V)
±5
±12
±15
±24
Output
Current max
(A)
±0.50
±0.21
±0.16
±0.1
Models
Triple output
Model
AME5-505TCJZ
AME5-512TCJZ
AME5-515TCJZ
AME5-524TCJZ
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Output
Voltage
(V)
Auxiliary
Output
Voltage
(V)
Output
Current max
(A)
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
120-370
120-370
120-370
120-370
5
5
5
5
±5
±12
±15
±24
0.8/±0.10
0.6/±0.10
0.6/±0.08
0.6/±0.05
2400/370
1600/170
1760/80
1170/50
70
73
74
75
Output
Current max
(A)
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
3360/370
2400/170
2160/170
3000/100
71
73
73
75
Models
Asymmetric Separated Dual output
Model
AME5-505DCJZ
AME5-512DCJZ
AME5-515DCJZ
AME5-524DCJZ
www.aimtec.com
F 052e R8
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
120-370
120-370
120-370
120-370
Output
Voltage
(V)
5/5
5/12
5/15
5/24
Tel: +1 514 620 2722
1 of 5
0.9/0.1
0.75/0.1
0.7/0.1
0.6/0.1
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME5-CJZ
5 Watt | AC-DC / DC-DC Converter
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Conditions
Typical
115 VAC
230 VAC
115 VAC
230 VAC
230VAC/50Hz
Recommended slow blow type
Maximum
125
80
Units
mA
mA
A
A
mA
A
10
20
0.3
1
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Line regulation
Load regulation (single output)
Load Regulation (dual output)
Load Regulation (triple &
asymmetric separated output)
Minimum load
Full load, main output
Full load, auxiliary output
10-100% load
10-100% Balanced load
10-100% Balanced load, main output
10-100% Balanced load, auxiliary output
Single output
Others
Ripple & Noise *
115VAC, 20MHz bandwidth
230VAC, 20MHz bandwidth
Hold-up time
±2
±0.5
±1.5
±1
±2
±3
±5
0
10
50
15
80
Maximum
Units
%
%
%
%
%
150
%
%
mV p-p
ms
ms
Rated
Units
3000
500
VAC
VDC
MΩ
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Isolation voltage between Main and Auxiliary output
Isolation Resistance
60 sec
60 sec
Typical
>1000
General Specifications
Parameters
Switching frequency
Conditions
Typical
Single and asymmetrical dual output
Dual and triple output
Maximum
Units
140
KHz
65
Class I
≥110
Zener diode clamp
Continuous, Auto recovery
-25 to +70
-25 to +105
Protection class
Over current protection
% of Iout
Over voltage protection
Short circuit protection
o
Operating temperature
See derating curve
C
o
Storage temperature
C
o
Maximum Case temperature
100
C
o
Temperature coefficient
±0.02
%/ C
Cooling
Free air convection
Humidity
Non condensing
95
% RH
Case material
Plastic (flammability to UL 94V-0)
Weight
50
g
Dimensions (L x W x H)
1.91 x 1.42 x 0.81 inches 48.5 x 36 x 20.5 mm
o
MTBF
> 300,000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME5-CJZ
5 Watt | AC-DC / DC-DC Converter
Safety Specifications
Parameters
Agency approvals
cULus, CE pending
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Standards
IEC/EN/UL 60950-1
EN55022, class B
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 3
IEC 61000-4-4 Level 3
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 3
IEC 61000-4-8 Level 3
IEC 61000-4-11 Class 2
Dimensions
3
2
Bottom
View
8
7
6
5
4
1
2
Top View
6
7
8
3
1
40.50
(1.59)
4.00
(0.16)
4
5
4.00
(0.16)
12.50
(0.49)
36.00
(1.42)
10.00
(0.39)
5.50
(0.22)
48.50
(1.91)
4.00
(0.16)
DIV: 10.00 (0.40)
20.50
(0.81)
Ø 1.50 (Ø 0.06)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004)
6.00
(0.24)
1.00
(0.04)
Pin Out Specifications
Pin
Single
Dual
Triple
Asymmetric Dual
1
2
3
4
5
6
7
8
Ground
AC Input (N)
AC Input (L)
-V Output
No pin
No pin
No pin
+V Output
Ground
AC Input (N)
AC Input (L)
-V Output
No pin
Common
No pin
+V Output
Ground
AC Input (N)
AC Input (L)
-V Output 1
+V Output 1
-V Output 2
Common
+V Output 2
Ground
AC Input (N)
AC Input (L)
-V Output 1
+V Output 1
No pin
-V Output 2
+V Output 2
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME5-CJZ
5 Watt | AC-DC / DC-DC Converter
Derating
Free Air Convection at 25°C
100
100
80
Output Power (%)
Output power (%)
Free Air Convection
Safe Operating Area
70
Input 100-240VAC or
120-340VDC
60
40
80
75
Safe Operating Area
60
40
20
20
0
85
100
(100) (120)
0
- 25
-20
-10
70
55
0
20
40
60
80
100
Ambient Temperature º C
240
(320)
264
(350)
Input Voltage VAC (VDC)
Typical application circuits
AC L
FUSE
1A/300V
Single Output
NTC
+ Vout
AC L
MOV
S14K350
AC N
DC
AC
FUSE
1A/300V
AC N
AC L
AC
- Vout
- Vout
+ Vout
DC
Com
C1
1µF/50V
C3
1µF/50V
AC N
Earth/GND
www.aimtec.com
TVS
+
Dual Output
NTC
MOV
S14K350
F 052e R8
C1
C2
1µF/50V
AC N
Earth/GND
AC L
+ Vout
- Vout
C2
+
C4
+
+ Vout
TVS 1
Com
TVS 2
- Vout
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME5-CJZ
5 Watt | AC-DC / DC-DC Converter
AC L
FUSE
1A/300V
Asymmetric
Dual Output
NTC
+
AC L
MOV
S14K350
DC +
AC
AC N
AC N
AC L
C3
1µF/50V
Vout 2
Earth/GND
FUSE
1A/300V
C1
1µF/50V
Vout 1
C2
C4
+ Vout 1
+
TVS 1
- Vout 1
+ Vout 2
+
TVS 2
-
- Vout 2
Triple Output
NTC
+
AC L
C1
1µF/50V
Vout 1
MOV
S14K350
-
AC N
AC N
AC
Earth/GND
+ Vout 2
DC
C5
1µF/50V
Com
C3
1µF/50V
C2
+
Single 3.3 & 5 Vout
Single 9 Vout
Single 12 Vout
Single 15 Vout
Single 24 Vout
Dual ±5 Vout
Dual ±12 Vout
Dual ±15 Vout
Dual ±24 Vout
Triple 5/±5 Vout
Triple 5/±12 & 5/±15
Vout
Triple 5/±15 Vout
Dual 5/5 Vout
Dual 5/12 Vout
Dual 5/15 Vout
Dual 5/24 Vout
TVS1
Vout 1
-
C6
+
C4
+
+ Vout 2
TVS2
Com
TVS3
- Vout 2
- Vout 2
Model
+
C2
C4
C6
TVS1
TVS2
TVS3
330 µF
120 µF
120 µF
68 µF
68 µF
120 µF
68 µF
47 µF
10 µF
220 µF
120 µF
68 µF
47 µF
10 µF
22 µF
22 µF
7V
12V
20V
20V
30V
7V
20V
20V
30V
7V
7V
20V
20V
30V
7V
7V
120 µF
22 µF
22 µF
7V
20V
20V
120 µF
220 µF
220 µF
120 µF
120 µF
22 µF
22 µF
22 µF
22 µF
22 µF
22 µF
-
7V
7V
7V
7V
7V
30V
7V
20V
20V
30V
30V
-
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This