MORNSUN IF0512S-1W 1w, fixed input, isolated & regulated single output dc-dc converter Datasheet

FEATURES
l Small Footprint
l SIP/DIP Package
l 3KVDC Isolation
l Temperature Range: -40°C to +85°C
1W, FIXED INPUT, ISOLATED & REGULATED l No Heat sink Required
l Internal SMD Construction
SINGLE OUTPUT DC-DC CONVERTER
l No External Component Required
l Industry Standard Pinout
l RoHS Compliance
IF_S-1W & IF_D-1W Series
APPLICATIONS
The IF_S-1W & IF_D-1W Series are specially designed for applications
where a group of polar power supplies are isolated from the input power
supply in a distributed power supply system on a circuit board.
These products apply to:
1) Where the voltage of the input power supply is fixed (voltage variation
≤±5%);
2) Where isolation is necessary between input and output (isolation
voltage ≤3000VDC);
3) Where the regulation of the output voltage and the output ripple noise
are demanded.
Patent Protection RoHS
MODEL SELECTION
Rated Power
Package Style
Output Voltage
Input Voltage
Product Series
PRODUCT PROGRAM
Input Voltage
(VDC)
Model
Nominal
Range
Output Voltage
(VDC)
Output Current
(mA)
Max.
Min.
Input Current
(mA)(Typ.)
@Max.
@No
Load
Load
Efficiency(%)
@Max. Load
Min.
Typ.
IF0505S-1W
5
200
20
303
62
66
IF0509S-1W
9
111
12
286
66
70
12
83
9
278
68
72
IF0512S-1W
5
4.75-5.25
30
IF0515S-1W
15
67
7
274
69
73
IF0505D-1W
5
200
20
303
62
66
IF0512D-1W
12
83
9
278
68
72
IF1205S-1W
5
200
20
124
63
67
IF1212S-1W
12
83
9
114
69
73
IF1215S -1W
15
67
7
113
70
74
IF1205D-1W
5
200
20
124
63
67
IF2405S-1W
5
200
20
62
63
67
12
83
9
57
69
73
IF2412S-1W
12
11.4-12.6
24
22.8-25.2
15
8
IF2415S-1W
15
67
7
56
70
74
IF2405D-1W
5
200
20
62
63
67
Typ.
Max.
Unit
Note: The IF_S(D)-W25 Series also available in our company.
OUTPUT SPECIFICATIONS
Item
Test condition
Min.
Line regulation
For Vin change of ±5%
--
--
±0.25
Load regulation
10% to 100% load
--
±1
±2
Output voltage accuracy
100% load
--
--
±3
Temperature drift
100% load
--
--
0.03
Output ripple*
20MHz Bandwidth
--
10
20
Output Noise*
20MHz Bandwidth
--
50
100
%
%/℃
mVp-p
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at DC-DC Application Notes.
COMMON SPECIFICATION
Item
Test Conditions
Min.
Typ.
Max.
Unit
Storage humidity range
Non condensing
--
--
95
%
The copyright and authority for the interpretation of the products are reserved by MORNSUN
IF_S-1W & IF_D-1W
2013.11.21-A/4
Page 1 of 4
Operating temperature
-40
--
85
Storage temperature
-55
--
125
Lead temperature
Ta=25°C
--
15
25
Temp. rise at full load
1.5mm from case for 10 seconds
--
--
300
Cooling
℃
Free air convection
Case material
Plastic(UL94-V0)
*IFXX05S/D-1W
--
1
--
S
Short circuit protection
Others
Switching Frequency
Continuous
100% load, Input voltage range
--
120
300
KHz
3500
--
--
K hours
IF_S-1W / IF_S-W75
--
2.1
--
g
IF_D-1W / IF_D-W75
--
2.4
--
g
MTBF
Weight
*Supply voltage must be discontinued at the end of short circuit duration.
ISOLATION SPECIFICATIONS
Item
Test condition
Min.
Typ.
Max.
Unit
Isolation voltage
Input-Output, tested for 1 minute and leakage current
less than 1 mA
3000
--
--
VDC
Isolation resistance
Input-Output, test at 500VDC
1000
--
--
MΩ
Isolation Capacitance
Input-Output,100KHz/0.1V
--
60
--
pF
TYPICAL CHARACTERISTICS
Temperature Derating Graph
Operating Temp.( C )
OUTLINE DIMENSIONS & PIN CONNECTIONS
IF_S-1W / IF_S-W75
IF_S-1W / IF_S-W75
The copyright and authority for the interpretation of the products are reserved by MORNSUN
IF_S-1W & IF_D-1W
2013.11.21-A/4
Page 2 of 4
APPLICATION NOTE
1)Requirement on output load
To ensure this module can operate efficiently and reliably, During operation, the minimum output load could not be less than 10% of the full load.
If the actual output power is very small, please connect a resistor with proper resistance at the output end in parallel to increase the load.
2)Recommended circuit
If you want to further decrease the input/output ripple, an “LC” filtering network may be connected to the input and output ends of the DC/DC
converter, see (Figure 1).
L
L
+Vo
Vin
DC DC
Cin
Cout
GND
0V
(Figure 1)
It should also be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid
mutual interference. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a startup problem might
arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees (Table 1).
EXTERNAL CAPACITOR TABLE (TABLE 1)
Vin
Cin
Vout
Cout
(VDC)
(μF)
(VDC)
(μF)
5
4.7
5
10
12
2.2
9
4.7
24
1
12
2.2
15
1
It’s not recommend to connect any external capacitor in the application field with less than 0.5 watt output.
3)Overload Protection
Under normal operating conditions, the output circuit of these products has no protection against over-current and short-circuits. The simplest
method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit.
4)Input Over-voltage Protection Circuit
The simplest device for input over-voltage protection is a linear voltage regulator with overheat protection that is connected to the input end in
series (Figure 2).
Vin
+Vo
REG
DC DC
GND
0V
(Figure 2)
5)When the environment temperature is higher than 71°C, the product output power should be less then 60% of the rated power.
6)It is not recommended to increase the output power capability by connecting two or more converters in parallel. The product is not
hot-swappable.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
IF_S-1W & IF_D-1W
2013.11.21-A/4
Page 3 of 4
Note:
1. Operation under minimum load will not damage the converter; However, they may not meet all specifications.
2. Max. Capacitive Load is tested at nominal input voltage and full load.
3. Unless otherwise noted, All specifications are measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load.
4. In this datasheet, all test methods are based on our corporate standards.
5. All characteristics are for listed models, and non-standard models may perform differently. Please contact our technical support for more detail.
6. Please contact our technical support for any specific requirement.
7. Specifications of this product are subject to changes without prior notice.
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China.
Tel: 86-20-38601850
Fax:86-20-38601272
E-mail: [email protected]
Http://www.mornsun-power.com
The copyright and authority for the interpretation of the products are reserved by MORNSUN
IF_S-1W & IF_D-1W
2013.11.21-A/4
Page 4 of 4
Similar pages