AIMTEC AMER120C-24500AZ Led driver / converter Datasheet

Click on Series name for product info on aimtec.com
Series AMER120C-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
Models
Single output
• AC-DC Constant Current or Constant
Voltage LED Driver
• Input range 90-305VAC/47-440Hz
• High Efficiency up to 88%
• Operating temperature -40 to 85°C
• Dimmable via resistive / 0-10Vdc / PWM
• 5 Years Limited Warranty
•
•
•
•
•
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
36-50
0-2.5
90-305/47-440
130-430
AMER120C-36340AZ
122.4
24-36
0-3.4
90-305/47-440
130-430
AMER120C-24500AZ
120
12-24
0-5
90-305/47-440
130-430
Model
AMER120C-50250AZ
125
Over Temperature Protection
Over Current Protection
Waterproof Case rated IP68
Power Factor Correction
Short Circuit Protection
Mode of Operation
Efficiency
(%)
115
230
277
87
87
87
87
85
88
88
88
88
86
86
88
88
88
87
VAC
Constant Current
Constant Voltage②
Constant Current
Constant Voltage②
Constant Current
VAC
VAC
Constant Voltage②
86
86
87
the maximum output power will permanently damage the converter.
② The dimming feature is not supported when units are used in Constant Voltage mode only.
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models
can be ordered with optional North American colour input wires. (add “-NA” to part number when ordering)
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-sale
AMER120C-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
① Exceeding
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
Power factor
External fuse
Start-up time
www.aimtec.com
F 052.1e R3.D
Conditions
Typical
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
0.98
0.94
0.92
3
900
Tel: +1 514 620 2722
1 of 6
Maximum
1800
800
700
45
60
70
0.25
3.5
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120C-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Output Specifications
Parameters
Conditions
Typical
Maximum
Conditions
Typical
Rated
500VDC
>1000
Current accuracy
±3
Line regulation
(LL-HL)
±2
Load regulation
0-100% load
±3
Ripple & Noise*
150
Hold-up time
80
Current adjustment range
100-10
④ Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor.
Isolation Specifications
Parameters
Tested voltage
Isolation resistance
I/O
I/FG
O/FG
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Over temperature protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Potting
Wires
Weight
Dimensions (L X H X W)
MTBF
3sec
Typical
Detect transformer temperature
With derating over 55 oC
≧105
≧105
Auto recovery
125
Refer to model application
%
%
%
mV p-p
ms
%
Units
3750
2000
500
Conditions
Units
VAC
VAC
VAC
MΩ
Maximum
Units
100
C
C
o
C
o
C
% / oC
125
KHz
%
%
o
o
-40 to +95
±0.02
Free air convection
Non condensing
20~95
Aluminum
Epoxy (IP68 rated)
UL1015 18AWG Input & 14AWG output *20CM
900
181.00 x 59.00 x 47.00 mm (7.13 x 2.32 x 1.85 inches)
>400,000 hrs (MIL-HDBK-217F at t=+25°C)
% RH
g
Safety Specifications
Parameters
Standards
www.aimtec.com
F 052.1e R3.D
Meets UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13
Information Technology Equipment
EN55022 Class B
Harmonic Current Emissions
IEC/EN 61000-3-2, Class C
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2 Level 3
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 2
Electrical Fast Transient / Burst Immunity
IEC 61000-4-4 Level 2
Surge Immunity
IEC 61000-4-5 Level 3
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8 Level 1
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Tel: +1 514 620 2722
2 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120C-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Dimensions
Derating
Free Air Convection
55 º C
100
80
Safe Operating Area
60
40
20
0
-40
-20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
3 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120C-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
Dimming Performance
AMER120C-24500AZ
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
4 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120C-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
AMER120C-36340AZ
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
5 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER120C-AZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter
AMER120C-50250AZ
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R3.D
Tel: +1 514 620 2722
6 of 6
Toll free: + 1 888 9 AIMTEC
(924 6832)