Arch BR360 Input under voltage protection Datasheet

VER : A_1
update : 2015.03.16
DC-DC Brick
BR360 SERIES
360 Watts
DESCRIPTION
KEY FEATURES















Input under Voltage Protection
Over Current Protection (Hiccup Mode)
Short Circuit Protection (Hiccup Mode)
Over Voltage Protection (Hiccup Mode)
Over Temperature Protection (Self-recovery)
Remote ON/OFF Control
Remote Sense
Output Voltage Trim
Negative Logic:BR360-3.3S and BR360-12S
Positive Logic:BR360-48S
UL60950-1 and CSA C22.2 No. 60950-1-07
Meet UL94V-0 Flammability Requirements
RoHS6 Compliant
Size: 2.4 x 2.28 x 0.5 Inches
3-Years Product Warranty
The BR360 series DC-DC converter are high-efficiency and power density
standard 1/2 brick isolated models. This series contain 6 modules, output
power from 100W to 360W, output voltage covering 3.3V, 5V, 12V and 48V four
levels. All models support primary ON/OFF control, remote Sense and Trim
function. This series which conform to the RoHS6 requirement can be used in
the fields of communication, data transmission and distributed power supply
system.
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1.0 m/s (200 LFM), Vin = 48 V, Vout = 12 V , unless otherwise specified.
Model No.
Max Output Wattage (W)
Voltage (V.DC.)
Input
Output
Protection
Current (A) (max)
No-Load Loss (W) (typ.)
Voltage Set Point (V.DC.)
Current (A) (max.)
Line Regulation (LL-HL) (typ.)
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
(Oscilloscope Bandwidth:20 MHz)
Efficiency (typ.)
100% Load
(Vin = 48 V; TA=25°C (77°F))
50% Load
20% Load
Over Power Protection
Over Current Protection
Over Voltage Protection
Short Circuit Protection (max.)
Over Temperature Protection
BR360-3.3S
198W
48V (36~75V)
7.5A
BR360-12S
360W
BR360-48S
153.6W
11A
5.5A
(Vin = 0 - 75 V; Iout = 60 A)
(Vin= 36 V; Iout = 30 A)
(Vin= 36 V; Iout = 3.2 A)
4W
3.3V
60A
0.2%
0.3%
4.3W
12V
30A
0.3%
0.5%
1.2W
48V
3.2A
1%
1%
150 mV
300 mV
300 mV
92%
94.8%
93%
93%
95.6%
92.5%
90%
92.9%
89.5%
Hiccup mode
Hiccup mode
3.8~5V
14~16.5V
53~59V
Hiccup mode
Hiccup mode
Hiccup mode
Hiccup mode
Threshold:105~130°C / Hysteresis:5°C (min.)
Self-recovery (The values are obtained by measuring the temperature of the PCB bottom near
the thermal resistor.)
Isolation
Environment
Voltage (V.DC.)
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
Humidity
MTBF
Safety
Agency Approvals
EMC
EMI (Conducted & Radiated Emission)
Physical
Other
Dimension (L x W x H)
Weight
Remote
On/Off Voltage
On/Off Current
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
Low level (V.DC.)
High level (V.DC.)
Low level (mA) (max.)
1500 VDC (Basic Isolation and Functional Isolation)
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
1.5 Million Hours
(Airflow = 1.5 m/s (300 LFM); TA = 40°C (104°F); 80% load;
.Telcordia SR332 Method 1 case 3)
CE, UL, TUV
UL60950-1 and IEC/EN60950
Class B Requirements in FCC and EN55022 (After Connecting to an
External Filtering Circuit)
2.4 x 2.28 x 0.5 Inches ( 61.0 x 57.9 x 13.0 mm ) Tolerance 0.5 mm
100 g
67.6 g
82 g
-0.7~1.2V
-2~0.8V
-0.7~1.2V
3.5~12V
3.5~18V
3.5~12V
1mA
-1-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR360 SERIES
360 Watts
NOTE
1. During the test of input reflected ripple current, the input terminal must be connected to a 12uH inductor and a 220uF electrolytic capacitor.
2. Point B, which is for testing the output voltage ripple, is 25 mm (0.98 in.) away from the Vout(+) pin.
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR360 SERIES
360 Watts
MECHANICAL DIMENSION
DIMENSIONS TOLERANCE
3.3S
PIN#
48S
12S
1
+DC IN
+DC IN
2
ON / OFF CTL
ON / OFF CTL
3
NC
CASE
4
-DC IN
-DC IN
5
-DC OUT
-DC OUT
6
-Sense
-Sense
7
Trim
Trim
8
+Sense
+Sense
9
+DC OUT
+DC OUT
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
.x
 0.2 mm (0.007 in)
.xx
 0.13 mm (0.005 in)
-3-