ETC2 EFB1712HHG 172 x 50.8 mm sery Datasheet

EFB
172 x 50.8 MM SERIES
DIMENSIONS DRAWING
+0.8
50.8 -0.3
172.0 0.5
( 6.772 0.020)
162.0 0.3
(6.378 0.012)
+0.031
(2.000-0.012
)
10.0
(0.394)
10.0
7.5
(0.295)
M4
LABEL
(0.394)
55
.5 o
7.5
(0.295)
5
55.
o
DELTA ELECTRONICS, INC
10.0
10.0
(0.394)
(0.394)
320.0 10.0
(12.598 0.394)
8- 4.3 0.3
(8- 0.169 0.012)
* Bearing Type
Air Pressure
30.0
1.00
25.0
0.80
20.0
0.60
15.0
0.40
10.0
0.20
5.0
0
0
FUNCTION
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
-R00 / -F00
SH
VH
HH
M
L
6.0
8.0
10.0 (M3/MIN)
0
2.0
4.0
0
80.0
160.0 240.0 320.0
UNIT:
2
(mm H O)
2
PART NO.
EFB1712LG
EFB1724LG
EFB1748LG
EFB1712MG
EFB1724MG
EFB1748MG
EFB1712HG
EFB1724HG
EFB1748HG
EFB1712HHG
EFB1724HHG
EFB1748HHG
EFB1724VHG
EFB1748VHG
EFB1724SHG
INLET SIDE
H
(IN H O)
MODEL
OUTLET SIDE
EFB1712/24/48XG
1.20
mm
(INCH)
MOUNTING PANEL CUTOUT
P & Q CURVE (AT RATED VOLTAGE)
Ball Bearings
* Material
Impeller : Plastic (UL 94V-0)
Frame : Die-Cast Aluminum
* Lead Wires :
UL 1007 AWG #24 OR Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
* Weight : 840g (29.62 oz)
UNIT:
(CFM)
mm
(INCH)
Air Flow
Rated
Voltage
Operating
Voltage
Range
Rated
Current
VDC
12
24
48
12
24
48
12
24
48
12
24
48
24
48
24
VDC
8.0 to 14.0
12.0 to 28.0
24.0 to 60.0
8.0 to 14.0
12.0 to 28.0
24.0 to 60.0
8.0 to 14.0
12.0 to 28.0
24.0 to 60.0
8.0 to 14.0
12.0 to 28.0
24.0 to 60.0
12.0 to 28.0
24.0 to 60.0
12.0 to 28.0
Amp
0.79
0.39
0.19
0.99
0.47
0.25
1.35
0.56
0.31
1.79
0.77
0.38
0.97
0.49
1.17
Rated
Input
Power
Watt
9.48
9.36
9.12
11.88
11.28
12.00
16.20
13.44
14.88
21.48
18.48
18.24
23.28
23.52
28.08
Speed
Maximum
Air Flow
Maximum
Air Pressure
Noise
R.P.M.
m3 /min
CFM
mmH 2 O
IN H 2 O
dB-A
2800
5.950
210.12
11.90
0.469
48.0
3050
6.520
230.25
14.50
0.571
50.0
3350
7.130
251.79
17.49
0.689
53.0
3700
7.920
279.69
20.30
0.800
55.0
4000
8.560
302.29
23.80
0.937
57.0
4300
9.203
325.00
27.5
1.083
59.0
* Function type is optional.
* The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specifications are subject to change without notice.
47
http://www.deltaww.com
Similar pages