XP Power IEQ0524S15 Dc-dc converter Datasheet

IEQ05 Series
DC-DC Converter
5 Watt
xxx Series
• Regulated Single & Dual Output
• Wide 4:1 Input Range
• Compact SIP8 Package
• 1500 VDC Isolation
• Operating Temperature -40 °C to +90 °C
• Remote On/Off
• 3 Year Warranty
Dimensions:
IEQ05:
0.86 x 0.37 x 0.44” (21.8 x 9.3 x 11.2 mm)
Models & Ratings
Input voltage
4.5-18V
9-36V
18-75V
Output voltage
Output current
Input current(1,2)
No load
Full load
Maximum
capacitive load(3)
Model number
3V3
1075 mA
390 mA
1000 µF
76%
IEQ0512S3V3
5V
1000 mA
515 mA
1000 µF
81%
IEQ0512S05
12 V
417 mA
500 mA
220 µF
83%
IEQ0512S12
15 V
334 mA
505 mA
100 µF
83%
IEQ0512S15
24 V
209 mA
510 mA
100 µF
82%
IEQ0512S24
±12 V
±209 mA
515 mA
±100 µF
81%
IEQ0512D12
±15 V
±167 mA
510 mA
±47 µF
82%
IEQ0512D15
3V3
1075 mA
195 mA
1000 µF
76%
IEQ0524S3V3
60 mA
5V
1000 mA
255 mA
1000 µF
81%
IEQ0524S05
12 V
417 mA
250 mA
220 µF
83%
IEQ0524S12
15 V
334 mA
250 mA
100 µF
84%
IEQ0524S15
24 V
209 mA
250 mA
100 µF
83%
IEQ0524S24
±12 V
±209 mA
255 mA
±100 µF
82%
IEQ0524D12
±15 V
±167 mA
255 mA
±47 µF
82%
IEQ0524D15
3V3
1075 mA
95 mA
1000 µF
76%
IEQ0548S3V3
30 mA
5V
1000 mA
130 mA
1000 µF
80%
IEQ0548S05
12 V
417 mA
125 mA
220 µF
83%
IEQ0548S12
15 V
334 mA
125 mA
100 µF
84%
IEQ0548S15
24 V
209 mA
125 mA
100 µF
82%
IEQ0548S24
±12 V
±209 mA
125 mA
±100 µF
82%
IEQ0548D12
±15 V
±167 mA
125 mA
±47 µF
83%
IEQ0548D15
20 mA
Notes
1. Input currents measured at nominal input voltage.
2. Input current is typically 2.5 mA at nominal input voltage when output is
remotely turned off.
1
Efficiency
3. Maximum capacitive load is per output.
www.xppower.com
IEQ05 Series
DC-DC Converter
Input
Characteristic
Input Voltage Range
Input Filter
Minimum
Typical
Maximum
4.5
18
9.0
36
18.0
75
Units
VDC
24 V nominal
48 V nominal
Internal Capacitor
36
Input Surge
50
12 V nominal
VDC for 1 s
100
Remote On/Off
Notes & Conditions
12 V nominal
24 V models
48 V models
ON: open circuit
OFF: 2-4 mA via 1kΩ resistor into pin 3 with respect to pin 1
Output
Characteristic
Output Voltage
Minimum
Typical
3.3
Initial Set Accuracy
Output Voltage Balance
±1
Maximum
Units
Notes & Conditions
30
VDC
See Models and Ratings table
±2
%
±2
%
For dual output with balanced laods
A
No minimum load required
Minimum Load
Line Regulation
±0.3
±0.5
%
Load Regulation
±0.5
±1.0
%
±5.0
%
5
% deviation
100
mV pk-pk
Cross Regulation
Transient Response
3
Ripple & Noise
Overload Protection
170
On dual output models when one load is varied between
25% and 100% and other is fixed at 100%
Recovery within 1% in less than 500 µs for a 25% load
change.
20 MHz bandwidth. Measured using 0.47 µF ceramic
capacitor.
%
Short Circuit Protection
Continuous, with auto recovery
Maximum Capacitive Load
See Models and Ratings table
Temperature Coefficient
0.02
%/ ˚C
Maximum
Units
General
Characteristic
Minimum
Efficiency
Isolation: Input to Output
Isolation Resistance
82
%
1500/1800
250
100
Power Density
35.7
Mean Time Between Failure
Weight
Notes & Conditions
See Models and Ratings table
VDC
60 s/1 s
pF
kHz
At 500 VDC
Ω
109
Isolation Capacitance
Switching Frequency
Typical
W/in3
2.4
MHrs
0.01 (4.8)
lb (g)
MIL-HDBK-217F, +25 °C GB
Environmental
Characteristic
Maximum
Units
Notes & Conditions
Operating Temperature
Minimum
-40
Typical
+90
°C
See Derating Curve.
Storage Temperature
-55
+125
°C
Case Temperature
+90
°C
Humidity
95
%RH
Cooling
Case Flammability
Non-condensing
Natural convection
UL 94V-0 Rated
Non conductive black plastic
www.xppower.com
2
IEQ05 Series
DC-DC Converter
Safety Approvals
Safety Agency
Safety Standard
Notes & Conditions
CB
IEC60950-1
ITE
UL
UL/cUL60950-1
ITE
EMC: Emissions
Phenomenon
Standard
Test Level
Conducted
EN55022
Class A
Notes & Conditions
EMC: Immunity
Phenomenon
Standard
ESD
Test Level
Criteria
EN61000-4-2
±8 kV air discharge, ±6 kV contact
A
Notes & Conditions
EN61000-4-3
10 V/m
A
EN61000-4-4
±2 kV
A
With external capacitor,
suggested part is CHEMI-CON KY 330µF/100V
Surge
EN61000-4-5
±1 kV
A
With external capacitor,
suggested part is CHEMI-CON KY 330µF/100V
Conducted
EN61000-4-6
10 V rms
A
0
Radiated
EFT/Burst
Mechanical Details
0.86 (21.8)
0.82 (20.8)
0.02
(3.5)
0.08
(2.0)
0.13
(3.2)
2x0.10
(2x2.54)
0.20
(5.08)
1
2
3
5
6
7
8
0.11 (2.7)
Bottom View
0.37 (9.3)
0.01 (0.25)
0.44 (11.2)
0.02 (0.5)
Pin Connections
0.02
(0.50)
3x0.10
(3x2.54)
Pin
1
2
3
5
6
7
8
Single
-Vin
+Vin
Remote On/Off
No Connection
+Vout
-Vout
No Connection
Dual
-Vin
+Vin
Remote On/Off
No Connection
+Vout
Common
-Vout
Notes
1. All dimensions are0in inches (mm)
2. Weight: 0.01 lbs (4.8 g) approx.
3. Tolerance: X.XX±0.01 (X.X±0.25)
X.XXX±0.005 (X.XX±0.13)
4. Pin Tolerance: ±0.002 (±0.05)
Application Notes
Derating Curve
Output Power (%)
100
0
-40
65
90
Ambient Temperature (°C)
3