MPD MA1548S-15RW 2:1 input range, 15w single & dual output dc/dc con vert er Datasheet

MA1500RWSeries
2:1 Input Range, 15W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 15W Output Power
• 2:1 Input Voltage Range
• Compact DIP Case
• 1,600 VDC I/O Isolation
• Meets EN 55032 “A”
• Single & Dual Outputs
• Remote On/Off Control
• Wide Temperature Operation
• Industry Standard Pin-Out
Input
Parameter
Conditions
Input Voltage Range
Start Up Time
Input Filter
Input Reflected Ripple Current
Output
Parameter
Output Voltage Accuracy
Line Regulation, VIN = Min to Max
Load Regulation, See Note 2
Cross Regulation, Dual Output
Ripple & Noise (20 MHz)
Transient Recovery Time, See Note 5
Transient Response Deviation
Output Power Protection
Temperature Coefficient
Output Short Circuit Protection
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Remote On/Off (See Page 3)
Parameter
Supply On
Supply Off
Standby Input Current
Control Common
Environmental
Parameter
Operating Temperature Range
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Min.
12 VDC Input
9.0
24 VDC Input 18.0
48 VDC Input 36.0
Nominal VIN & Constant Resistive Load
␲ (Pi) Filter
Conditions
Min.
Typ.
12.0
24.0
48.0
20
Typ.
±1.0
Single Output
Dual Output
Single Output
Dual Output
See Note 3
See Note 4
Max.
18.0
36.0
72.0
20.0
mA P - P
Max.
Units
%
250
±3.0
150
±0.02
Continuous (Autorecovery)
Conditions
Input/Output, 60 Seconds
Case/Input, Output, 60 Seconds
500 VDC
100 kHz/1V
Conditions
See Note On Page 3
Min.
1,600
1,600
1,000
Typ.
Max.
Ambient
Case
Min.
-40
%
%
mV P - P
µSec
%
% IOUT
%/ºC
Units
M⍀
pF
kHz
Typ.
Max.
12
1.2
Units
VDC
VDC
mA
Max.
+85
+100
+125
Units
ºC
ºC
ºC
5.0
Referenced to -Input (Pins 2, 3)
Conditions
%
VDC
2,000
330
Min.
3.0
0.0
VDC
mS
±0.2
±0.5
±0.5
±1.0
±5.0
60
25% Load Step Change
Units
Typ.
-40
Free Air Convection
RH, Non-condensing
95
%
See Mechanical Diagram (Page 3)
Copper With Nickel Coating (UL94V-0)
0.705 Oz (20g)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
460
Typ.
Max.
Units
kHours
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
Typ.
Max.
36.0
50.0
100.0
260
Units
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
www.micropowerdirect.com
Model Selection Guide
Input
Output
Model
Number
Voltage (VDC)
Current (mA)
Voltage
Nominal
Range
Full-Load No-Load (VDC)
MA1512S-03RW
12
9.0 - 18.0
1,309
15
3.3
MA1512S-051RW
12
9.0 - 18.0
1,465
15
5.1
MA1512S-12RW
12
9.0 - 18.0
1,436
15
12.0
MA1512S-15RW
12
9.0 - 18.0
1,420
15
15.0
MA1512D-05RW
12
9.0 - 18.0
1,488
15
±5.0
MA1512D-12RW
12
9.0 - 18.0
1,420
15
±12.0
MA1512D-15RW
12
9.0 - 18.0
1,420
15
±15.0
MA1524S-03RW
24
18.0 - 36.0
647
10
3.3
MA1524S-051RW
24
18.0 - 36.0
732
10
5.1
MA1524S-12RW
24
18.0 - 36.0
710
10
12.0
MA1524S-15RW
24
18.0 - 36.0
702
10
15.0
MA1524D-05RW
24
18.0 - 36.0
744
10
±5.0
MA1524D-12RW
24
18.0 - 36.0
710
10
±12.0
MA1524D-15RW
24
18.0 - 36.0
710
10
±15.0
MA1548S-03RW
48
36.0 - 75.0
327
5
3.3
MA1548S-051RW
48
36.0 - 75.0
370
5
5.1
MA1548S-12RW
48
36.0 - 75.0
359
5
12.0
MA1548S-15RW
48
36.0 - 75.0
359
5
15.0
MA1548D-05RW
48
36.0 - 75.0
372
5
±5.0
MA1548D-12RW
48
36.0 - 75.0
359
5
±12.0
MA1548D-15RW
48
36.0 - 75.0
355
5
±15.0
Current
Current
(mA, Max)
(mA, Min)
4,000
3,000
1,250
1,000
±1,500
±625
±500
4,000
3,000
1,250
1,000
±1,500
±625
±500
4,000
3,000
1,250
1,000
±1,500
±625
±500
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
Notes:
1. The specified maximum capacitive load is for each output.
2. Load regulation is specified for a load change of 0% to 100%.
3. When measuring cross regulation, the load on one output is varied from 25% to 100% while the other output is held
at 100%.
4. Output ripple is measured with a 1.0 µF capacitor connected from the +VOUT to the -VOUT pins for single output units and from
each output to common for dual output models. See the typical connection diagram & notes on page 3.
5. Transient recovery is measured to within a 1% error band for a load step change of 75% to 50% to 25%.
6. Operation at no-load will not damage these units. However, they may not meet all specifications.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the
correct rating.
Over
Max
Rating
Voltage Capacitive Efficiency Fuse
Slow-Blow
Protection
Load
(%, Typ)
(mA)
(VDC)
3.9
6.2
15.0
18.0
±6.2
±15.0
±18.0
3.9
6.2
15.0
18.0
±6.2
±15.0
±18.0
3.9
6.2
15.0
18.0
±6.2
±15.0
±18.0
(µF Max)
4,700
3,300
600
400
±1,500
±288
±200
4,700
3,300
600
400
±1,500
±288
±200
4,700
3,300
600
400
±1,500
±288
±200
86
89
89
90
86
90
90
87
89
90
91
86
90
90
86
88
89
89
86
89
90
MPD offers a wide range of DC/DC converters in the standard 24 pin DIP package. Models range from 1W to 15W and offer wide input
ranges, high isolation & tight regulation. Many
are approved to EN 60950. For full information,
go to our website or contact the factory.
Temperature Derating Curve
Efficiency vs Output Load: 12 VIN Models
Efficiency vs Output Load: 24 VIN Models
Efficiency vs Output Load: 48 VIN Models
Page 2
We Power Your Success - For Less
3,000
3,000
3,000
3,000
3,000
3,000
3,000
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,000
1,000
1,000
1,000
1,000
1,000
1,000
www.micropowerdirect.com
Typical Connection
To meet the requirements of EN 61000-4-4 & EN 61000-4-5, the external filter capacitors (C1 & C2) in the diagram above) are required. The
recommended value for C1 & C2 is 330 µF/100V. A single 680 µF/100V
capacitor may also be used.
When measuring output ripple, it is recommended that an external 1.0
µF ceramic capacitor be placed from the +VOUT pin to the -VOUT pin for
single output units and from each output to common for dual output
units. For noise sensitive applications, the use of 3.3 µF capacitors will
reduce the output ripple.
The Remote On/Off circuit is referenced to the minus input of the unit
(pins 2 & 3). If the On/Off input (pin 1) is connected to the minus input,
the unit is shut off. If pin 1 is left open, the unit operates normally.
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFM
Standard
EN 55032
EN 55032
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
Criteria/Level
Class A
Class A
B
A
B
B
A
A
Mechanical Dimensions
Pin Connections
Pin
Single
1
Remote On/Off
2
-VIN
3
-VIN
9
No Pin
11
NC
14
+VOUT
16
-VOUT
22
+VIN
23
+VIN
NC: No Connection
Dual
Remote On/Off
-VIN
-VIN
Common
-VOUT
+VOUT
Common
+VIN
+VIN
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages