AIMTEC AMEL5-5SCJZ Over current, over voltage protection Datasheet

Click on Series name for product info on aimtec.com
Series AMEL5-CJZ
5 Watt | AC-DC / DC-DC Converter
Picture coming soon
FEATURES:
•
•
•
•
•
•
•
•
I/O Isolation 4000VAC
Operating Temp: -25 °C to +70 °C
Input: 85-264VAC, 47-63Hz, or 100-370VDC
Over current, Over Voltage Protection
High efficiency up to 83%
No load consumption ≤ 0.3W
Ultra small package
Short Circuit Protection
Models
Single output
Model
AMEL5-3.3SCJZ
AMEL5-5SCJZ
AMEL5-12SCJZ
AMEL5-15SCJZ
AMEL5-24SCJZ
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
Output
Voltage
(V)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
100-370
100-370
100-370
100-370
100-370
3.3
5
12
15
24
Output
Current max
(A)
Maximum
capacitive
Load
(µF)
Efficiency
(%)
4000
4000
820
820
330
74
78
80
82
83
Maximum
Units
1.25
1
0.42
0.333
0.23
230
VAC
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
Conditions
Typical
115 VAC
230 VAC
115 VAC
230 VAC
150
70
10
20
0.2
Recommended slow blow type
No load (110/230VAC)
mA
mA
A
A
mA
A
W
1.5
0.3
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise *
Hold-up time (minimum)
Conditions
Typical
3.3V output
Others
±3
±2
±0.5
±1
60
50
12
80
10-100% load
20MHz Bandwidth, 3.3 / 5V models
20MHz Bandwidth, others
115VAC
230VAC
Maximum
Units
%
%
%
120
100
mV p-p
ms
*Ripple and Noise are measured at 20MHz bandwidth by using the referenced Application circuit.
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
Typical
60 sec
4000
>1000
Conditions
Typical
Rated
Units
VAC
MΩ
General Specifications
Parameters
Switching frequency
Protection class
Over Current protection
Over voltage protection
Short circuit protection
Operating temperature
Storage temperature
www.aimtec.com
F 052e R8
Auto recovery
See derating curve
140
Class II
≥110
Zener diode clamp
Continuous, hiccup, Auto recovery
-25 to 70°C
-25 to +105
Tel: +1 514 620 2722
1 of 3
Maximum
Units
KHz
% of Iout
°C
°C
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-CJZ
5 Watt | AC-DC / DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
Maximum Case temperature
100
°C
Temperature coefficient
0.02
% /°C
Cooling
Free air convection
Humidity
Non condensing
95
% RH
Case material
Plastic (flammability to UL 94V-0)
Weight
31
g
Dimensions (L x W x H)
2.0 x 1.0 x 0.6 inches 50.80 x 25.40 x 15.16mm
o
MTBF
> 300,000 hrs (MIL-HDBK -217F, t=+25 C)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency approvals
cULus, CE pending
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Standards
IEC/EN/UL 60950-1
EN55022, class B
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 3
IEC 61000-4-4 Level 3, Level 4 with recommended EMC circuit
IEC 61000-4-5 Level 3, Level 4 with recommended EMC circuit
IEC 61000-4-6 Level 3
IEC 61000-4-8 Level 3
IEC 61000-4-11, Class 2
Dimensions
50.80
(2.00)
45.72
(1.80)
1
Case Temperature
Measurement point
3
1
TOP VIEW
0.40
(10.16)
25.40 20.32
(1.00) (0.80)
TOP VIEW
4
+
2
2
15.16
(0.60)
6.00
(0.24)
4
5
Ø 1.5 (Ø 0.06)
Ø 0.04
(1.00)
3
DIV: 5.08 (0.2)
Dimensions: inch (mm)
Case Tolerance:± 0.50 (0.02)
Pin Pitch Tolerance: ± 0.10 (0.004)
Pin Out Specifications
Pin
Single
1
2
3
4
AC Input (N)
AC Input (L)
+V Output
-V Output
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-CJZ
5 Watt | AC-DC / DC-DC Converter
Derating
Free Air Convection at 25°C
Free Air Convection
100
80
Output Power (%)
100
Safe Operating Area
70
Input 110-240VAC or
140-340VDC
60
50
40
20
80
Safe Operating Area
60
50
40
20
0
0
- 25
-20
-10
70
55
0
20
40
60
85 110
(100) (140)
100
80
Ambient Temperature º C
240
(340)
264
(370)
Input Voltage VAC (VDC)
Typical application circuit
AC L
FUSE
1A/250V
Single Output
NTC
4
AC L
MOV
S14K350
AC
AC N
+ Vout
DC
AC N
C1
C2
1µF/50V
+
3
- Vout
EMC recommended circuit
AC L
FUSE
1A/250V
MOV
S14K350
LDM
4.7µH/2A
Single Output
LCM
2.2mH
NTC
CY1
1nF/
400VAC
CX
0.1µF/
275VAC
CY2
1nF/
400VAC
AC N
+Vout
+Vout
AC N
AC
DC
AC L
- Vout
C1
C2
1µF/50V
+
- Vout
GND
Model
3.3 & 5 Vout
9, 12 & 15
Vout
24 Vout
C2
220 µF / 35V
120 µF / 35V
47 µF / 35V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only