AIMTEC AME1-24SBAZ Ac-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AME1-AZ
1Watt | AC-DC Converter
FEATURES:
•
•
•
•
•
Models
Single output
I/O Isolation 3000VAC
Operating Temp: -40°C to +80°C
Input: 90-305VAC, 47-440Hz, or 130-430 VDC
Optional 90-528VAC, 47-440Hz, or 130-745 VDC
Over load, Short Circuit Protection
• RoHS compliant
• Energy Star compliant
• Ultra small package
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
Output
Current max
(mA)
AME1-3.3SAZ
AME1-5SAZ
AME1-12SAZ
AME1-15SAZ
AME1-24SAZ
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
90-305/47-440
130-430
130-430
130-430
130-430
130-430
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
3.3
5
12
15
24
300
200
83
67
42
AME1-3.3SBAZ
AME1-5SBAZ
AME1-12SBAZ
AME1-15SBAZ
AME1-24SBAZ
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
90-528/47-440
130-745
130-745
130-745
130-745
130-745
-40 to +80
-40 to +80
-40 to +80
-40 to +80
-40 to +80
3.3
5
12
15
24
300
200
83
67
42
Model
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input Dissipation (No Load)
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation (single output)
Transient Recovery Time
Transient Response Deviation
Minimum load
Ripple & Noise
Conditions
Typical
Recommended slow blow type
1
≦0.5
115 VAC
230 VAC
277 VAC
480VAC
115 VAC
230 VAC
277 VAC
480 VAC
Conditions
Typical
Full load (typical)*
LL-HL, Full Load
0-100% load (typical)*
25% load step
3.3/5 VAC With 560µF E/C
12/15 VAC With 220µF E/C
24 VAC With 220µF E/C
±5
±1.5
±5
200
±2
0
200
400
500
Maximum
capacitive
Load
(µF)
Efficiency
(%)
115
230
277
2200
1100
680
560
470
62
58
73
77
79
59
57
68
68
79
58
56
65
70
77
2200
1100
680
560
470
51
57
62
61
58
51
57
62
59
58
50
56
60
58
56
VAC
Maximum
25
20
15
5
10
15
20
30
0.15
Maximum
VAC
VAC
480
VAC
44
50
51
50
48
Units
mA
mA
mA
mA
A
A
A
A
mA
A
W
Units
%
%
%
µs
% of Vout
%
mV p-p
mV p-p
mV p-p
*Ripple &Noisemeasuredat 20MHz bandwidth with 0.1µFand 115/230/277/480 VAC( Typical input ) with Full Load
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
www.aimtec.com
F 052e R8.B
Conditions
Typical
60 sec
>1000
Tel: +1 514 620 2722
1 of 3
Rated
3000
Units
VAC
MΩ
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME1-AZ
1Watt | AC-DC Converter
General Specifications
Parameters
Switching frequency
Over Load protection
Short circuit protection
Operating temperature
Storage temperature
Maximum Case temperature
Humidity
Case material
Weight
Dimensions (L x W x H)
Conditions
Typical
100
>125%
Auto recovery
Auto recovery
Without derating
Maximum
Units
KHz
o
-40 to +80
-40 to +85
C
C
o
C
% RH
o
100
Non condensing
20 ~ 95
Plastic resin + Fiberglass (flammability to UL 94V-0)
25
g
1.327 x 0.874 x 0.71 (33.70 x 22.20 x 18.00mm)
> 400,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
MTBF
> 100,000 hrs (MIL-HDBK -217F, t= at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Environment Approval
Parameters
Conditions
Wave form: Half sine wave
Acceleration amplitude: 5gn
Shock
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Vibrations
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
www.aimtec.com
F 052e R8.B
cULus, CE, CB (pending), CSA
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity(1KV)
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Canadian Safety Agency
IEC/EN/UL 60950-1:2006+A11:2009
EN55022, class B
IEC/EN 61000-3-2, (EN60555-2)
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1)
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
CAN/CSA-C22.2 NO. 60950-1-07
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME1-AZ
1Watt | AC-DC Converter
Pin Out Specifications
Pin
Single
1
2
3
4
AC Input (N)
AC Input (L)
-V Output
+V Output
Dimensions
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.B
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages