Dallas DT322FGK An economical means of transferring power Datasheet

Double-throw safety switch
Industrial
Light Commercial
Residential
Agricultural
An economical means
of transferring power
Double-throw
safety switches
Eaton’s double-throw safety switches are used to transfer service from a normal power
source to an alternate source, or to switch from one load circuit to another. The manually
operated double-throw safety switch provides an economical means of transferring power.
Eaton offers a full line of general-duty and heavy-duty double-throw safety switches.
Double-throw general-duty
non-fusible safety switches
Double-throw, 240 Vac
general-duty, non-fusible
compact design
Specifications
•
30–100A
Specifications
•
Suitable for service entrance
use with neutral kit installed
•
30–400A
•
Horsepower rated
•
Suitable for service entrance
use with neutral kit installed
•
Suitable for use as a manually
operated switch per 2005
NEC Article 702
•
UL listed File No. E5239
•
Quick-make, quick-break
operating mechanism
•
Suitable for use as a manually operated switch per 2005
NEC� Article 702
•
UL� listed File No. E5239
Features
General-duty
Heavy-duty
Eaton’s general-duty doublethrow safety switches are
commonly applied in emergency
power or generator applications
to reduce or eliminate the costly
impact of power loss from the
typical source in residential,
agricultural and light commercial markets. All general-duty
double-throw safety switches
are non-fusible and are available
up to 400A.
Eaton’s heavy-duty doublethrow safety switches are
designed for commercial and
industrial applications. Fusible
switches are available through
600A, while non-fusible switches
are manufactured up to 800A.
The wiring configuration from
the factory allows a single load
to be supplied by a normal
or alternate source; however,
where necessary, the wiring can
be field modified to allow two
loads to be alternately supplied
by a single power source.
A standby generator connected
to a residential wiring system
must be installed according to
the National Electrical Code.�
A double-throw switch must be
installed to isolate and disconnect wiring from normal utility
lines so that generator-produced
electricity is not back-fed
onto normal utility lines.
Whether normal electrical
service is disrupted by severe
weather conditions, accidents or
other issues, an Eaton generalduty double-throw safety switch
is a critical component in your
standby generator applications.
Heavy-duty double-throw
safety switches are designed
to accommodate a wide range
of accessories that can be factory
or field installed. Customized
solutions, including key interlocks, viewing windows and
receptacles, are also available
through Eaton’s Switching
Device Flex Center.
Double-throw, 240 Vac
general-duty, non-fusible,
quick-make, quick-break
design
•
Palm-fitting, visible
red handle
•
Tri-lingual nameplate
•
NEMA� 3R enclosure with
side opening door
•
Visible, embossed
ON-OFF indication
•
Concentric knockouts on
bottom endwall and sides
•
Lockable door hasp
•
Lockable handle
•
Three-point mounting
•
Factory-installed neutral
(optional catalog numbers are
available without a neutral)
•
Terminals suitable for 60º
or 75ºC Al or Cu wire
•
Rounded shroud
•
•
•
Mechanical door interlock to
prevent easy access when the
switch is in the ON position
Suitable for use on a circuit
capable of delivering
not more than 10,000 rms
symmetrical amperes
Compact size
•
Door cannot be opened with
the switch ON. Switch cannot
be turned ON with door open
(without operating interlock
defeater)
•
Suitable for use on a circuit
capable of delivering not
more than 100,000 rms
symmetrical amperes when
protected by Class R or J fuses
(30–200A); R, T or J fuses
(400A). Short-circuit rating
is 10,000 rms symmetrical
amperes when protected
by any other overcurrent
protective device
•
Double-break visible rotary
blades; quick-make, quickbreak operation
DT223URH-N
Compact Design, 100A, 240V
DT224URK-NPS
Quick-Make, Quick-Break Design,
200A, 240V.
Features
•
Palm-fitting, visible
red handle
Double-Throw Compact Design
NEMA 3R
Enclosure
Rainproof
Ampere
Rating
Main and
Standby
ON
•
Tri-lingual nameplate
•
NEMA 3R enclosure with
side opening door
•
Visible, embossed red
ON-OFF indication
30
60
100
Tangential knockouts
(30–100A) on bottom endwall; concentric knockouts on
higher ratings, and sides and
rear of 30–100A
Non-Fusible Two-Pole, Three-Wire—240 Vac—Solid Neutral
30
DT221URH-N
ON
60
DT222URH-N
OFF
100
DT223URH-N
ON
•
•
Lockable door hasp
•
Lockable handle
•
Factory-installed neutral
(optional catalog numbers are
available without a neutral)
•
Three-point mounting
(30–100A)
•
Four-point mounting
(200–400A)
•
Terminals suitable for 60º
or 75ºC Al or Cu wire on
30–100A; 75ºC Al or Cu wire
on higher ratings
•
Rounded shroud
OFF
Catalog Number
S/N
ON
DT221URH
DT222URH
DT223URH
ON
Non-Fusible Two-Pole—240 Vac
Non-Fusible
Two-Pole
OFF
ON
S/N
Double-Throw Quick-Make, Quick-Break Design
Ampere
Rating
Main and
Standby
Maximum
Horsepower Ratings
Non-Fusible
Two-Pole with
Neutral
Two Sources or
Two Loads
ON
OFF
ON
Single-Phase
NEMA 3R
Enclosure
Rainproof
240 Vac
Catalog Number
250 Vdc
Two Sources or
Two Loads
ON
S/N
OFF
ON
Non-Fusible Two-Pole—240 Vac—250 Vdc
30
3
5
DT221URKPS
Non-Fusible
ON
60
10
10
DT222URKPS
Two-Pole
OFF
100
20
20
DT223URKPS
Two Sources or
ON
200
15
40
DT224URKPS
Two Loads
400
—
50
DT225URKPS
Non-Fusible Two-Pole, Three-Wire—240 Vac—250 Vdc—Solid Neutral
30
3
5
DT221URK-NPS
60
10
10
DT222URK-NPS
100
20
20
DT223URK-NPS
Non-Fusible
ON
200
15
40
DT224URK-NPS
Two-Pole with
OFF
Neutral
400
—
50
DT225URK-NPS
S/N
ON
Two Sources or
Two Loads
ON
OFF
2
EATON CORPORATION Double-throw safety switch 
EATON CORPORATION Double-throw safety switch 
ON
3
Double-throw heavy-duty
fusible safety switches
Double-throw heavy-duty
non-fusible safety switches
DT363URK
Double-throw Heavy-Duty NonFusible Safety Switch, 100A, 600V
DT363FGK
Double-throw Heavy-Duty Fusible
Safety Switch, 100A, 600V
Double-throw 240 and
600 Vac heavy-duty, fusible
Features
Specifications
30–600A
•
Horsepower rated
•
•
Palm-fitting, visible red handle
•
Tri-lingual nameplate
•
Side opening doors on
all enclosures
•
Suitable for service entrance
use with neutral or ground
lug kit installed
•
Suitable for use as a
manually operated switch
per 2005 NEC Article 702
•
•
UL listed File No E5239
•
•
•
Clear line shield to prevent
accidental contact with
energized parts; probe holes
enable line side testing
without removing the shield
Wiring configuration from
factory allows a single load
to be supplied by a normal
or alternate source; can be
modified to allow two loads
to be alternately supplied
by a single power source
Visible, embossed red
ON-OFF indication
Tangential knockouts
(30–100A) on top and bottom
endwall (bottom only on
NEMA 3R); concentric knockouts on higher ratings, and
sides and rear of 30–100A
•
Lockable door hasp
•
Lockable handle
•
Three-point mounting
(30–100A)
•
•
•
•
Four-point mounting
(200–600A)
Terminals suitable for 60º
or 75ºC Al or Cu wire on
30–100A; 75ºC Al or Cu wire
on higher ratings
•
Rounded shroud
•
Full range of accessories
•
Door cannot be opened
with the switch ON.
Switch cannot be turned ON
with door open (without operating interlock defeater)
Double-throw 240 and
600 Vac heavy-duty,
non-fusible
Suitable for use on a circuit
capable of delivering not
more than 100,000 rms symmetrical amperes when protected by Class R or J fuses
(30–200A); R, T or J fuses
(400–600A). Short-circuit rating is 10,000 rms symmetrical
amperes when protected by
any other overcurrent protective device
Specifications
•
Suitable for use as a
manually operated switch per
2005 NEC Article 702
Double-break visible rotary
blades; quick-make, quickbreak operation
•
UL listed File No. E5239
•
30–800A
•
Horsepower rated
•
Suitable for service entrance
use with neutral or ground
lug kit installed
Fuse Class
Provision
Maximum Horsepower Ratings
with Time-Delay Fuses
NEMA 1
Enclosure Indoor
NEMA 3R
Enclosure Rainproof
Single-Phase
240 Vac
Three-Phase
240 Vac
250 Vdc
Catalog
Number
Catalog
Number
—
DT224FGK
DT224FRK
Two-Pole—240 Vac—250 Vdc
200
H
15
40
Ampere
Rating Main
and Standby
OFF
ON
7-1/2
15
30
60
125
50
DT321FGK
DT322FGK
DT323FGK
DT324FGK
DT325FGK
DT326FGK
5
10
20
40
50
50
DT321FRK
DT322FRK
DT323FRK
DT324FRK
DT325FRK
DT326FRK
Palm-fitting, visible red handle
•
Tri-lingual nameplate
•
Side opening doors on all enclosures
•
Visible, embossed red
ON-OFF indication
•
Tangential knockouts
(30–100A) on top and bottom endwall (bottom only on
NEMA 3R); concentric knockouts on higher ratings, and
sides and rear of 30–100A
•
Lockable door hasp
•
Lockable handle
Maximum Horsepower
Ratings
ON
Three-Pole—240 Vac—250 Vdc
30
H
3
60
H
10
100
H
15
200
H
15
400
H
—
600 1
T
—
•
ON
OFF
ON
Fusible
Two-Pole
Two Sources
Fusible
Three-Pole
Two Sources
ON
OFF
ON
ON
OFF
ON
Fusible
Two-Pole
Two Loads
Fusible
Three-Pole
Two Loads
A Only available for use with fast-acting fuses. Standard hp rating is shown.
•
Three-point mounting (30–100A)
•
Four-point mounting
(200–800A)
•
Terminals suitable for 60º
or 75ºC Al or Cu wire on
30–100A; 75ºC Al or Cu wire
on higher ratings
•
Rounded shroud
•
Full range of accessories
•
Door cannot be opened
with the switch ON; switch
cannot be turned ON with
door open (without operating
interlock defeater)
•
Suitable for use on a circuit
capable of delivering not more
than 100,000 rms symmetrical
amperes when protected by
Class R or J fuses (30–200A);
R, T or J fuses (400–800A).
Short-circuit rating is 10,000
rms symmetrical amperes
when protected by any other
overcurrent protective device
•
Double-break visible rotary
blades; quick-make, quickbreak operation
Double-Throw 240 Vac Heavy-Duty, Non-Fusible
Double-Throw 240 Vac Heavy-Duty, Fusible
Ampere
Rating
Main
and
Standby
Features
SinglePhase
Three-Phase
NEMA 1
Enclosure
Indoor
NEMA 3R
Enclosure
Rainproof
240 Vac
240 Vac
Catalog
Number
Catalog
Number
DT221UGK
DT222UGK
DT223UGK
DT224UGK
DT225UGK
DT226UGK
—
—
—
DT224URK
DT225URK
—
DT321UGK
DT322UGK
DT323UGK
DT324UGK
DT325UGK
DT326UGK
DT327UGK 1 2
DT327UGK-N
—
—
DT323URK
DT324URK
DT325URK
—
—
—
250 Vdc
Non-Fusible Two-Pole—240 Vac—250 Vdc
30
3
—
5
60
10
—
10
100
20
—
20
200
15
—
40
400
—
—
50
600
—
—
—
Non Fusible Three-Pole—240 Vac—250 Vdc
30
3
10
5
60
10
20
10
100
20
40
20
200
15
60
40
400
—
125
50
600
—
125
50
800
—
125
50
800
—
125
50
ON
OFF
ON
ON
OFF
ON
Non-Fusible
2-Pole
Two Sources or Two Loads
ON
Non-Fusible
3-Pole
Two Sources or Two Loads
OFF
S/N
ON
Non-Fusible
3-Pole with Neutral
Two Sources or Two Loads
A Warning: Switch is not approved for service entrance.
B Field-installable neutral kit is not available. If a neutral is required, order the catalog number shown in the table with “N” suffix.
Double-Throw 600 Vac Heavy-Duty, Fusible
Ampere
Rating
Main
and
Standby
Maximum Horsepower Ratings
with Time-Delay Fuses
Fuse Class
Provision
Single-Phase
Three-Phase
480
Vac
600
Vac
480
Vac
600
Vac
10
25
40
50
—
15
30
60
125
250
20
50
75
150
350
Three-Pole—600 Vac—250 Vdc
30
H
7-1/2
60
H
20
100
H
30
200
H
50
400
T
—
4
EATON CORPORATION Double-throw safety switch 
NEMA 1
Enclosure
Indoor
NEMA 3R
Enclosure
Rainproof
NEMA 4X Enclosure,
Corrosion-Resistant
Stainless Steel
250
Vdc
Catalog
Number
Catalog
Number
Catalog
Number
—
—
—
40
50
DT361FGK
DT362FGK
DT363FGK
DT364FGK
DT365FGK
—
—
DT363FRK
DT364FRK
DT365FRK
DT361FWK
DT362FWK
DT363FWK
DT364FWK
DT365FWK
Fusible
Three-Pole
Two Sources
ON
OFF
ON
Fusible
Three-Pole
Two Loads
EATON CORPORATION Double-throw safety switch 
5
Double-throw heavy-duty
non-fusible safety switches
Double-throw heavy-duty
switching neutral safety switches
Double-Throw 600 Vac Heavy-Duty, Non-Fusible
Maximum Horsepower Ratings
Ampere
Rating
Main and
Standby
Single-Phase
NEMA 3R
Enclosure
Rainproof
NEMA 12
Enclosure
Industrial,
Dust-Tight
NEMA 4X
Enclosure, Corrosion-Resistant,
Stainless Steel
480 Vdc
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Three-Phase
480 Vac 600 Vac 480 Vac 600 Vac
Two-Pole—600 Vac—250 Vdc
30
7-1/2
10
60
20
25
100
40
50
200
50
50
400
—
—
600
—
—
Three-Pole—600 Vac—250 Vdc
30
7-1/2
10
60
20
25
100
40
50
200
50
50
400
—
—
600
—
—
800
—
—
800
—
—
NEMA 1
Enclosure
Indoor
—
—
—
—
—
—
—
—
—
—
—
—
5
10
20
40
50
50
DT261UGK
DT262UGK
DT263UGK
DT264UGK 1
DT265UGK
DT266UGK
—
—
—
DT264URK 1
DT265URK
DT266URK
—
—
—
—
—
—
—
—
—
—
—
—
20
50
75
125
250
250
250
250
30
60
100
150
350
350
350
350
5
10
20
40
50
50
50
50
DT361UGK
DT362UGK
DT363UGK
DT364UGK
DT365UGK
DT366UGK
DT367UGK 2 3
DT367UGK-N
DT361URK
DT362URK
DT363URK
DT364URK
DT365URK
DT366URK
DT367URK 2 3
DT367URK-N
DT361UDK 4
DT362UDK 4
DT363UDK 4
DT364UDK 4
DT365UDK 4 5
—4
—4
—4
DT361UWK
DT362UWK
DT363UWK
DT364UWK
DT365UWK
—
—
—
30
60
100
150
350
350
350
5
10
20
40
50
50
50
—
—
—
DT464UGK
DT465UGK
DT466UGK
DT467UGK
DT461URK
DT462URK
DT463URK
DT464URK
DT465URK
DT466URK
DT467URK
—
—
—
—
—
—
—
—
—
—
—
—
—
—
30
60
100
5
10
20
—
—
—
DT661URK
DT662URK
DT663URK
—
—
—
—
—
—
Two-Pole
OFF
Two Sources or
Two Loads
ON
S/N
Four-Pole—600 Vac—250 Vdc 2
30
7-1/2
10
20
60
20
25
50
100
40
50
75
200
—
50
125
400
—
—
250
600
—
—
250
800
—
—
250
Six-Pole—600 Vac—250 Vdc 2
30
7-1/2
10
15
60
20
25
50
100
40
50
75
Non-Fusible
ON
Non-Fusible
ON
Three-Pole
OFF
Two Sources or
Two Loads
ON
Non-Fusible
ON
Three-Pole with Neutral
OFF
Two Sources or
Two Loads
ON
Non-Fusible
ON
OFF
ON
Four-Pole
Two Sources or
Two Loads
ON
OFF
ON
A Rated 600 Vdc, 50 hp in addition to ratings shown in table.
B Warning: Switch is not approved for service entrance.
C Field-installable neutral kit is not available. If a neutral is required, order the catalog number shown in the table with “N” suffix.
D NEMA 12 enclosures (30–800A) can be field modified to meet NEMA 3R rainproof requirements when a factory-provided drain hole is opened.
E Also available in 240 Vac, catalog number DT325UDK.
Non-Fusible
Six-Pole
Two Sources or
Two Loads
Double-throw safety switches
applied in emergency power
or generator applications may
require a switched neutral in lieu
of a solid neutral. If the neutral
of the generator is bonded
to a grounding system at the
generator, then a separately
derived system (reference NEC
250-20[D] and Exhibit 250.7) has
been created and a switched
neutral in the double-throw safety
switch is required. The switching
neutral is required to avoid the
potential for backfeeding of the
power that might occur if the
safety switch neutral is also
bonded. If the generator neutral
is brought to the service where
it is bonded and grounded, then
a non-separately derived system
has been created and a solid
neutral must be used in the
double-throw safety switch.
Most double-throw safety
switches in today’s market are
provided with solid neutrals and
are not UL listed for switching
neutral application. The market,
some utilities and local codes
are requiring the ability to break
or switch the neutral on threeand four-pole double-throw
switches with a UL listing for that
capability. Three-pole switches
are used for single-phase
switching neutral applications,
while four-pole switches are used
for three-phase switching neutral
applications. In many cases, threeand four-pole double-throw safety
switches are being installed in
the field with the left-most pole
being used as the switching
neutral, but the switch is not
UL listed for that application.
Eaton non-fusible three-pole and
four-pole double-throw safety
switches 30–800A are UL listed
for switching neutral application
with the proper installation of
the applicable switching neutral
bonding kit shown in the
Accessories section of this brochure. Each bonding kit comes
with applicable materials, hardware, instruction sheet and
adhesive-backed wiring schematic.
The bonding kits can only be
used on non-fusible double-throw
safety switches. When a bonding kit is applied to a three-pole
switch, the switch becomes a
single-phase switch with singlephase horsepower ratings.
A double-throw safety switch
with the appropriate bonding kit
installed is suitable for service
entrance use. Typically, a four-pole
double-throw safety switch is not
suitable for service entrance use;
however, with the appropriate
bonding kit installed, the fourpole switch is suitable for service
entrance use as noted on the
device publication of the product.
Switching neutral bonding kits
can also be factory installed
by Eaton’s unique Switching
Device Flex Center. See the end
of this brochure for additional
information on the Flex Center.
Bonding kit schematic
Single-phase applications requiring a neutral pole bonding kit
Bonding kit schematic
Three-phase applications requiring a neutral pole bonding kit
NNotes: NEC 702 application, separately derived system
and service equipment.
Two sources with switched neutral,
generator is a separately derived system.
Proper installation is governed by interpretation of the NEC,
applicable local codes and local utility requirements. Applicable
sections of these codes and requirements should be
referenced prior to installation.
Double-Throw Switching Neutral
Safety Switch
(upper switch base assembly
is shown)
6
EATON CORPORATION Double-throw safety switch 
EATON CORPORATION Double-throw safety switch 
7
Accessories, hubs and
standard lug capacities
1. DT200NK
200A Neutral/Ground Kit
2. DS250H2
Plate Type Hub
3. DS26FK
60A 600V R Fuse Adapter Kit
Accessories
Hubs
Neutral, ground lug, control pole and auxiliary contact kits contain
materials for one switch base. Copper lug, 60A J fuse and R fuse
kits contain materials for one three-pole switch base. Switching neutral bonding and 400A J fuse kit contents are for one complete double-throw switch. Applicable accessories for a specific safety switch
can also be found on the inside door publication of the switch
Catalog Number DS900AP Adapter Kit permits installation of
Group 1 hubs on 200A double-throw switches.
Description
Catalog Number
Neutral Kits/Ground Kits 1
30–100A
200A
400A Non-Fusible
600A Non-Fusible
400–600A Fusible
Ground Lug Kits 1
30–100A 2
200A
400–800A
Switching Neutral Bonding Kits 3
30–100A, Three-Pole, Four-Pole Non-Fusible
200A, Three-Pole, Four-Pole Non-Fusible
400A, Three-Pole, Four-Pole Non-Fusible
600A, Three-Pole, Four-Pole Non-Fusible
800A, Three-Pole, Four-Pole Non-Fusible
Control Pole Kit 1
30–800A
Auxiliary Contact Kits 1
1NO/1NC
2NO/2NC
Copper Lug Kits 1
30–60A
100A
J Fuse Adapter Kits 4
60A
400A 600V
R Fuse Adapter Kits 4
30A, 240V
30A, 600V; 60A, 240V
60A, 600V
100A, 240–600V
200A, 240–600V
400A, 240V
Lubricating Grease for Safety Switch
Blades and Contacts
Each kit contains three 30 cc tubes of
lubricating grease.
DT100NK
DT200NK
DT400NK
DT600NK
DS800NK
DS100GK
DS200GK
DS468GK
DT100BK
DT200BK
DT400BK
DT600BK
DT800BK
DS16CP
7. DS200EK1
Auxiliary Contact Kit
1NO/1NC
5. DS468GK
400–800A Ground Lug Kit
8. DS16CP
Control Pole Kit
6. DS050MH
Myers Hub
9. DS26JK
60A J Fuse Adapter Kit
10. DS16CL
30–60A Copper Lug Kit
1
2
3
4
5
6
7
8
9
10
Plate Type Hubs
For NEMA 3R Enclosures (Up to 200A)
Group 1
General-Duty, Heavy-Duty,
Double-Throw through 100A
Group 2
General-Duty, Heavy-Duty,
Double-Throw through 200A
Conduit Size
in Inches (mm)
Catalog
Number
Conduit Size
in Inches (mm)
Catalog
Number
0.75 (19.1)
1.00 (25.4)
1.25 (31.8)
1.50 (38.1)
2.00 (50.8)
DS075H1
DS100H1
DS125H1
DS150H1
DS200H1
2.00 (50.8)
2.50 (63.5)
3.00 (76.2)
— —
— —
DS200H2
DS250H2
DS300H2
—
—
Myers Type Hubs
NEMA 3R (400A and Above)
NEMA 4X (Stainless Steel) and 12
Conduit Size
in Inches (mm)
Catalog
Number
0.50 (12.7)
0.75 (19.1)
1.00 (25.4)
1.25 (31.8)
1.50 (38.1)
2.00 (50.8)
2.50 (63.5)
3.00 (76.2)
3.50 (88.9)
4.00 (101.6)
5.00 (127.0)
DS050MH
DS075MH
DS100MH
DS125MH
DS150MH
DS200MH
DS250MH
DS300MH
DS350MH
DS400MH
DS500MH
DS200EK1
DS200EK2
Standard lug capacities
DS16CL
DS36CL
DS26JK
DT400JK
DS12FK
DS16FK
DS26FK
DS36FK
DS46FK
DS56FK
DSLUBEKIT
A For heavy-duty and general-duty quick-make, quick-break.
B Ground bar kit is not listed on device publications.
C For heavy-duty non-fusible.
D For heavy-duty fusible.
8
4. DT100BK
100A Switching Neutral
Bonding Kit
EATON CORPORATION Double-throw safety switch 
Although certain lug capacities are larger than required, only minimum wire bending space is provided per the requirements noted in
NEC Tables 373-6 (a) and (b) for respective ampere ratings.
Description
30A
60A
100A
200A
400A
600A Fusible
600A Non-Fusible
800A
Copper-Bodied Lugs
30A
60A
100A
200A
400A
600A
Minimum
Wire Size
Maximum
Wire Size
Wire
Type
#14
#14
#14
#6
(2) #1/0
(1) #1/0
(1) #2
(1) #1/0
(2) #250
(3) #250
#2
#2
#1/0
250 kcmil
(2) 300 kcmil
(1) 750 kcmil
(1) 600 kcmil
(1) 750 kcmil
(2) 500 kcmil
(3) 500 kcmil
Cu/Al
Cu/Al
Cu/Al
Cu/Al
Cu/Al
Cu/Al
Cu/Al
Cu/Al
Cu/Al
Cu/Al
#14
#14
#6
#6
#1/0
(2) #1/0
#6
#4
#1/0
250 kcmil
500 kcmil
(2) 500 kcmil
Cu
Cu
Cu
Cu
Cu
Cu
EATON CORPORATION Double-throw safety switch 
9
Dimensions and weights
1
2
W
W
H
2. Heavy-Duty NEMA 1, 3R
30–800A
H
CL
3. Heavy-Duty NEMA 12, 4X
30–400A
H
Note
Contact your
Eaton sales office for
outline drawings and
mounting dimensions.
D2
NEMA 3R
Dimensions in Inches (mm)
Short-Circuit Ratings Using Class R, T or J Fusing
Where Applicable
Class H fuse clips supplied as standard for 30–600A except Class T for
400A at 600V, and 600A at 240V. Rated at 10,000 rms symmetrical when using
Class H fuses.
D2
Double-Throw General-Duty, Non-Fusible, 240V, Two-Pole
Solid Neutral, Quick-Make, Quick-Break Design
30
60
100
200
400
D
W
D
D2
Ampere
Rating
1. General-Duty NEMA 3R
30–400A
3
D
CL
Short-circuit ratings
Double-Throw General-Duty, Non-Fusible, 240V, Two-Pole
Solid Neutral, Compact Design
Height (H)
Width (W)
Depth (D)
Depth (D2)
Weight
Lbs (kg)
Ampere
Rating
24.63 (625.6)
24.63 (625.6)
24.63 (625.6)
37.38 (949.5)
53.81 (1366.8)
11.94 (303.3)
11.94 (303.3)
11.94 (303.3)
19.56 (496.8)
23.13 (587.5)
9.88 (251.0)
9.88 (251.0)
9.88 (251.0)
11.25 (285.8)
12.50 (317.5)
5.38 (136.7)
5.38 (136.7)
5.38 (136.7)
6.10 (154.9)
8.88 (225.6)
34 (15.4)
34 (15.4)
34 (15.4)
80 (36.3)
140 (63.6)
30
60
100
NEMA 3R
Dimensions in Inches (mm)
Height (H)
Width (W)
Depth (D)
Depth (D2)
Weight
Lbs (kg)
14.69 (373.1)
14.69 (373.1)
14.69 (373.1)
9.63 (244.6)
9.63 (244.6)
9.63 (244.6)
10.81 (274.6)
10.81 (274.6)
10.81 (274.6)
5.23 (132.8)
5.23 (132.8)
5.23 (132.8)
12 (5.4)
12 (5.4)
12 (5.4)
Not applicable to the Compact Design. The Compact Design is suitable for use
on a circuit capable of delivering not more than 10,000 rms symmetrical amperes.
Ampere
Rating
Voltage
Ratings
Type 1
Type 3R
Type 12
Type 4X
30
60
100
200
400
600
800
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
—
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
100k at 600
—
Double-Throw Heavy-Duty, Non-Fusible, 240V and 600V, Three-Pole
NEMA 1, 3R
Dimensions in Inches (mm)
NEMA 12, 4X Stainless Steel
Dimensions in Inches (mm)
Ampere
Rating
Width
(W)
Height
(H)
Depth
(D)
Depth
(D2)
Weight
Lbs (kg)
Width
(W)
Height
(H)
Depth
(D)
Depth
(D2)
Weight
Lbs (kg)
30
11.94
(303.3)
11.94
(303.3)
11.94
(303.3)
19.56
(496.8)
23.13
(587.5)
24.13
(612.9)
24.13
(612.9)
24.63
(625.6)
24.63
(625.6)
24.63
(625.6)
37.38
(949.5)
53.81
(1366.8)
63.31
(1608.1)
63.31
(1608.1)
9.88
(251.0)
9.88
(251.0)
9.88
(251.0)
11.25
(285.8)
12.50
(317.5)
14.13
(358.9)
14.13
(358.9)
5.38
(136.7)
5.38
(136.7)
5.38
(136.7)
6.10
(154.9)
7.25
(184.2)
8.88
(225.6)
8.88
(225.6)
34
(15.4)
34
(15.4)
34
(15.4)
80
(36.3)
140
(63.6)
175
(79.4)
175
(79.4)
12.00
(304.8)
12.00
(304.8)
12.00
(304.8)
19.50
(495.3)
23.00
(584.2)
—
25.88
(657.4)
25.88
(657.4)
25.88
(657.4)
41.00
(1041.4)
57.50
(1460.5)
—
10.25
(260.4)
10.25
(260.4)
10.25
(260.4)
11.63
(295.4)
12.50
(317.5)
—
5.50
(139.7)
5.50
(139.7)
5.50
(139.7)
6.48
(164.6)
7.25
(184.2)
—
60
(27.2)
60
(27.2)
60
(27.2)
105
(47.6)
185
(83.9)
—
—
—
—
—
—
60
100
200
400
600
800
Double-Throw Heavy-Duty, Fusible, 240V and 600V, Three-Pole
NEMA 1, 3R
Dimensions in Inches (mm)
NEMA 12, 4X Stainless Steel
Dimensions in Inches (mm)
Ampere
Rating
Width
(W)
Height
(H)
Depth
(D)
Depth
(D2)
Weight
Lbs (kg)
Width
(W)
Height
(H)
Depth
(D)
Depth
(D2)
Weight
Lbs (kg)
30
11.94
(303.3)
11.94
(303.3)
11.94
(303.3)
19.56
(496.8)
25.38
(644.7)
27.44
(697.0)
36.63
(930.4)
36.63
(930.4)
36.63
(930.4)
50.88
(1292.4)
74.75
(1898.7)
86.13
(2187.7)
9.88
(251.0)
9.88
(251.0)
9.88
(251.0)
11.25
(285.8)
14.13
(358.9)
14.13
(358.9)
5.38
(136.7)
5.38
(136.7)
5.38
(136.7)
6.10
(154.9)
8.88
(225.6)
8.88
(225.6)
44
(20.0)
44
(20.0)
44
(20.0)
95
(43.1)
230
(104.3)
320
(145.1)
12.00
(304.8)
12.00
(304.8)
12.00
(304.8)
19.56
(496.8)
25.38
(644.7)
—
39.81
(1011.2)
39.81
(1011.2)
39.81
(1011.2)
55.63
(1413.0)
74.75
(1898.7)
—
10.25
(260.4)
10.25
(260.4)
10.25
(260.4)
11.63
(295.4)
14.13
(358.9)
—
5.50
(139.7)
5.50
(139.7)
5.50
(139.7)
6.46
(164.1)
8.92
(226.6)
—
45
(20.4)
45
(20.4)
45
(20.4)
100
(45.4)
260
(117.9)
—
60
100
200
400
600
10
EATON CORPORATION Double-throw safety switch 
Non-fusible switches
Renewal parts
The UL listed short-circuit
ratings for Eaton non-fusible
switches are based on the
switches being properly protected by overcurrent protective
devices. For applications that
require a UL listed short-circuit
rating of 10,000 rms symmetrical
amperes or less, an Eaton nonfusible switch must be properly
protected by any overcurrent
protective device rated no greater
than the ampere rating of the
switch. For applications that
require a UL listed short-circuit
rating of greater than 10,000
rms symmetrical amperes, an
Eaton non-fusible switch must
be properly protected by the
appropriate class and size fusing
noted on the switch publication.
Otherwise, this non-fusible
switch must be replaced with
an Eaton fusible switch that uses
the appropriate fusing required.
Replacement parts for a specific
catalog number are shown on
the inside door label (publication) of the switch. Switch
bases, fuse bases, line shields
(fusible switches) and operating
handles (400A and above) are
typically available as applicable.
For additional information,
refer to Renewal Parts Catalog
RP00801001E.
Safety switch short circuit ratings are applicable to AC only.
Flex center
Our Cleveland, TN, Switching
Devices Flex Center is a solutions center that designs and
modifies safety switches,
enclosed circuit breakers and
rotary disconnects for unique
customer needs that are not
met by standard products. The
Flex Center is a one-of-a-kind
operation that is capable of
solving our customers’ issues,
while our competition is content
to offer their customers only
catalog items.
The Flex Center staff has over
120 years of design, manufacturing and industry experience,
and has been providing solutions
to our customers since 1998.
While you may think that your
power switching needs are
unlike any other, chances are,
the Flex Center staff has already
“been there, done that.”
For further information on
our customized solutions for
harsh environments, safety
and convenience, please refer
to our Flex Center brochure
SA00801002E or contact the
Flex Center at 1-888-329-9272.
Safety switch I2t and Ip values
are identical to UL maximum
acceptable I2t and Ip values for
the corresponding class fuse.
EATON CORPORATION Double-throw safety switch 
11
Eaton’s Electrical Sector is
a global leader in power
distribution, power quality,
control and automation, and
monitoring products. When
combined with Eaton’s full-scale
engineering services, these
products provide customerdriven PowerChainE solutions
to serve the power system
needs of the data center,
industrial, institutional, public
sector, utility, commercial,
residential, IT, mission critical,
alternative energy and OEM
markets worldwide.
PowerChain solutions help
enterprises achieve sustainable
and competitive advantages
through proactive management
of the power system as a
strategic, integrated asset
throughout its life cycle,
resulting in enhanced safety,
greater reliability and energy
efficiency. For more information,
visit www.eaton.com/electrical.
Eaton Corporation
Electrical Sector
1111 Superior Ave.
Cleveland, OH 44114
United States
877-ETN-CARE (877-386-2273)
Eaton.com
© 2010 Eaton Corporation
All Rights Reserved
Printed in USA
Publication No. BR00801002E / Z10432
November 2010
PowerChain Management is a registered
trademark of Eaton Corporation.
All other trademarks are property of their
respective owners.
Similar pages