ETC2 ECW0.5 Copper enamelled wire Datasheet

Copper Enamelled Wire
Description:
Soft Grade 2 Enamelled Copper Wire to BS EN 60317/20.
Part Number Table
Description
Enamel Coat
(mm)
Tolerance
Diameter
(mm)
Min.
(mm)
On Conductor Increase Max.
O.D.
in Dia.
Wire, Copper Enamelled, 35SWG
0.2
Wire, Copper Enamelled, 34SWG
0.224
± 0.003
Wire, Copper Enamelled, 33SWG
0.25
Wire, Copper Enamelled, 30SWG
0.315
Wire, Copper Enamelled, 27SWG
0.4
Wire, Copper Enamelled, 25SWG
0.5
Wire, Copper Enamelled, 24SWG
0.56
Wire, Copper Enamelled, 22SWG
0.71
Wire, Copper Enamelled, 21SWG
0.8
Wire, Copper Enamelled, 19SWG
1
Wire, Copper Enamelled, 18SWG
1.25
± 0.013
Wire, Copper Enamelled, 16SWG
1.5
± 0.015
± 0.004
Resistance
Ω/m @ 20°C
Part Number
Min.
Nom.
Max.
0.027
0.0239
0.5237
0.5441
0.5657
ECW0.2
0.029
0.0266
0.4188
0.4338
0.4495
ECW0.224
0.032
0.0297
0.3345
0.3482
0.3628
ECW0.25
0.035
0.367
0.2121
0.2193
0.227
ECW0.315
0.04
0.459
0.1316
0.136
0.1407
ECW0.4
0.045
0.566
0.08462
0.08706
0.08959
ECW0.5
± 0.006
0.047
0.63
0.06736
0.0694
0.07153
ECW0.56
± 0.007
0.053
0.789
0.04198
0.04318
0.04442
ECW0.71
0.056
0.884
0.03305
0.03401
0.035
ECW0.80
0.063
1.094
0.02116
0.02176
0.0224
ECW1.0
0.067
1.349
0.01353
0.01393
0.01435
ECW1.25
0.071
1.606
0.0094
0.00967
0.00995
ECW1.5
± 0.005
± 0.008
Important Notice : This data sheet and its contents (the “Information”) belong to the members of the Premier Farnell group of companies (the “Group”) or are licensed to it. No licence is granted
for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change
without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any
error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any
assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the
Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its negligence.
pro - POWER is the registered trademark of the Group. © Premier Farnell plc 2012.
www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
Page <1>
24/01/13
V1.2