ETC2 H40A-2000-AZC-15V H40 shock proof optical encoder Datasheet

H40 Shock Proof Optical Encoder
The H40 is an ultra heavy duty encoder whose internal structure is totally
isolated from severe shock and shaft loading ­conditions. The optics and
electronics are supported in shock absorbing material within the heavy
cast outer housing. The encoder shaft is flexibly coupled to the high load
capacity bearings and shaft assembly, which is carried in the outer
housing. The entire bearing assembly is field-removable
to permit proper shaft support while pressing pulleys, gears, etc. onto the shaft. An Underwriters
Laboratories listed version of this model is available.
The H40 Shock Proof Encoder is avail­­able with the following certifications:
EN 55011 and
EN 61000-6-2
Mechanical Specifications
Shaft Diameter: 5/8” nominal
Flats On Shaft: Two flats, 0.75” long X 0.30” deep at 90º
Shaft Loading/Bearing Life: Refer to figure 1, back page
Shaft Runout: 0.001” T.I.R. at mid-point of shaft
Starting Torque at 25° C: 10.0 in-oz (max)
Bearings: Class 52100 SAE high carbon steel,
stainless steel option
Shaft Material: 1070 carbon steel, 303 and 316
stainless steel optional
Enclosure: Die cast aluminum, hard anodized with dichromate sealed finish (optional). Shaft seals and sealed bearings
are standard to achieve environmental ratings.
Maximum RPM: 10,000 RPM (see frequency response, below)
Coupling Windup: The H40 uses an internal coupling.
Windup error (degrees) = a X 7.5 X 10-4 rad/sec2
where a = angular acceleration in rad/sec2
Weight: Approx 9 lbs
U.S. Standards Class I,
Group D, Division 1
C
Electrical Specifications
Output Format: 2 channels in quadrature, 1/2 cycle index
gated with negative B channel
Cycles per Shaft Turn: 1 to 72,000 (see Table 3).
For resolutions above 3,600 see interpolation options in the
BEI 2008 Spec Guide on pages 36 and 37.
Supply Voltage: 5 to 28 VDC available
Current Requirements: 100 mA typical + output load,
250 mA (max)
Voltage/Output: (see note 5)
15V/V: Line Driver, 5–15 VDC in, Vout = Vin
28V/V: Line Driver, 5–28 VDC in, Vout = Vin
28V/5: Line Driver, 5–28 VDC in, Vout = 5 VDC
28V/OC: Open Collector, 5 – 28 VDC in, OCout
Protection Level: Reverse, overvoltage and output
short ­circuit (see note 5)
Frequency Response: 100 KHz, up to 1 MHz with
­interpolation option (see note 5)
Output Terminations: see Table 2, back page
Termination Type: Compression type, UL recognized.
Accepts AWG 14 to 22, stranded wire, strip 1/4”
Note: Consult factory for other electrical options
H40 Shock Proof Ordering Options
Canadian Standards Class I,
Group D, Division 1
Environmental Specifications
Enclosure Rating: NEMA 4 X & 6 (IP66), outdoor ­
Non-Hazardous locations, NEMA 4 X & 13 (IP66),
indoor Non-Hazardous locations
Hazardous Area Rating: The optional Underwriters
Laboratories listed version is for use in hazardous locations;
NEMA Enclosure 7. Class 1, Group D, Division 1,
NEC Class 2 circuits only
Temperature: Operating, 0º to 70º C; extended temperature
testing available (see note 6); 80º C max for UL and CEN
approved units; storage; -25º to 90º C
Shock: 200 g’s at 11msec
Vibration: 5 to 2000 Hz @ 20 g’s
Humidity: 100% RH
NOTES & TABLES:
All notes and tables referred to in the text can be found on
the back page.­­
for assistance call 800-350-2727
Use this diagram, working from left to right to construct your model number (example: H40A-2000-ABZC-28V/V-SC-UL).
All notes and tables referred to can be found on the back of this page.
H40
TYPE:
H = Heavy Duty;
40 = 4.00” Square
CYCLES PER TURN:
Enter Cycles
See Table 3
HOUSING
CONFIGURATION:
A = Base Mounted Feet
B = No Mounting Feet
No. of Channels:
A = Single Channel
AB = Dual Quad. Ch.
ABZ = Dual with Index
AZ = Single with Index
See note 1
COMPLEMENTS:
C = Complementary
Outputs,
Blank = None
See note 2
Voltage/output:
15V/V = 5–15 Vin/out
28V/V = 5–28Vin/out
28V/5 = 5–28Vin/5Vout
28V/OC = 5–28Vin/
OCout
See note 3
SPECIal
OUTPUT TERMINATION:
features:
SC = Side Conduit
S= Special
EC = End Conduit; Conduit uses 1/2–14
features specified
NPSF (dryseal) straight pipe threads;
on purchase order
EM16 = MS3102R16S-1P
(consult factory)
EM18 = MS3102R18-1P,
See note 4
See Table 1, back page
CERTIFICATION:
UL = UL Explosion
Proof rating, only
available with SC
termination
Tel: 805-968-0782 /800-350-2727 | Fax: 805-968-3154 / 800-960-2726 | 7230 Hollister Ave., Goleta, CA 93117-2807 | www.beisensors.com
Specification No. 02045-001 Rev.08-11
H40 Shock Proof Optical Encoder
H40A
Tables
Figure 1
Table 1 Output Functions
Bearing Life vs. Speed at Various Radial Loads
4.5
Ø .281 (4)
Ø 0.6248
0.6244
Ø 3.56
Ø
4.5
Ø 0.6248
0.6244
Incremental
TERMINAL
A
B
Z
V
G
CG
A
B
Z
S
Ø .281 (4)
Ø 0.6248
0.6244
FUNCTION
CHANNEL A
B
Z
+VDC
GROUND (0V)
CASE GROUND
1/4-20 UNC-2B
0.50 DEEP A
(4) ON
A Ø 3.0 B.C.
B
Z
4.5
SPARE*
*or SELECT on Dual Count
encoders
Ø 3.56
Ø
4.5
Ø 0.6248
0.6244
1/4-20 UNC-2B
0.50 DEEP (4) ON
A Ø 3.0 B.C.
Ø
8-Bit Absolute*
GRAY
CODE
G0
G1
G2
G3
G4
G5
G6
G7
NATURAL
BINARY
20
21
22
23
24
25
26
27
SPARE
SPARE
LATCH
INTERROGATE
SPARE
+VDC
0V (COMMON)
CASE GROUND
TERMINAL
NUMBER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Latch and Interrogate are optional
Table 2
1/4-20 UNC-2B
0.50 DEEP (4) ON
A Ø 3.0 B.C.
M16
CONNECTOR
H40B
Incremental Output Terminations
CHANNELS DESIGNATED
IN MODEL NUMBER
PIN
A
B
C
D
E
F
G
1/4-20 UNC-2B
0.50 DEEP (4) ON
A Ø 3.0 B.C.
ABZ
M18 CONNECTOR
ABC
PIN
CHANNEL
A
B
C
D
F
G
H
I
J
CHANNEL A
B
Z
+VDC
GROUND (OV)
CASE GROUND
A
2.1 B
Z
A
A
B
B
Z
A
+V(SUPPLY VOLTAGE)
­­—
B
OV (CIRCUIT COMMON)
CASE GROUND (CG)
9.36
4.00
.281 DIA (4)
1.30
2.39
1.56
Table 3
4.75
3.56
DIA
0.6248
0.6244
DIA
Disc Resolutions for Incremental Encoder Model H40
Field Replaceable Coupling
& Bearing Assembly
Rear View
0.75
1, 2, 3, 5, 6, 7, 8, 10, 13, 16, 20, 24, 25, 26, 30,
32, 33,
34, 36,
2.146
± 0.005
37, 40, 45, 48, 50, 51, 56*, 60, 64, 66, 72, 75, 80, 86, 88, 90,
100, 102, 120, 122,125, 127, 128, 132, 144, 148, 150, 158,
COUPLING ACCESS PORT
160, 175, 176, 180, 187, 192, 200, 202, 204*, 217, 220, 240,
250, 254, 255, 256, 264*, 274, 280, 283, 288, 292, 300, 312,
320, 321, 325, 360, 366, 372, 375, 377, 380, 381, 384, 385,
393, 400, 430, 432, 450, 462, 480, 490, 500, 502, 508, 512,
522, 530, 550, 560*, 576, 598, 600, 604, 625, 628, 635, 638,
640, 660, 672, 676, 680, 687, 690, 700, 720, 725, 735, 740, 744,
748, 750, 762, 768, 780, 785, 800, 812, 825, 850, 864, 878, 888,
900, 912, 914, 938, 942, 955, 960, 1000, 1016, 1024, 1030,
1035, 1036, 1040, 1054, 1056, 1074, 1076, 1080,1088, 1100,
1101, 1125, 1136, 1200, 1237, 1250, 1257, 1270, 1280, 1300,
1/2 1314,
- NPSF1332,
(DRYSEAL)
PIPE THREADS
1333,STRAIGHT
1390, 1400,
1414, 1427, 1440, 1484,
NOTE: THIS WIRING PORT WILL BE SEALED WITH A PIPE
PLUG
IF
THE
EM
OR
EC
OPTION
IS
SPECIFIED
1500, 1562, 1570, 1596, 1600,
1650, 1666, 1718, 1745,
1774, 1800, 1840*, 1850, 1855, 1875, 1894, 1920, 1952,
1968, 1979, 1995, 2000, 2048, 2080, 2094, 2100, 2160,
2164, 2199, 2200, 2250, 2356, 2400, 2485, 2500, 2514,
2519, 2540, 3000, 3125, 3600, 4000, 4096, 5000
*AB or ABC output only. NOTE: Resolutions up to 72,000 are available.
BEARING RATING LIFE (HOURS)
Dimensions
Notes
SPEED (RPM)
1. Mounting is usually done either using the D-style square flange mount, E- or
G-style servo mounts, or one of the standard face mounts, F1 for example. Consult
factory for additional face mount options.
2.The shaft seal is recommended in virtually all installations. The most common exceptions are applications requiring a very low starting torque or those requiring operation at
both high temperature and high speed.
3. Non-standard index widths and multiple indices are available by special order.
Consult factory.
4. Complementary outputs are recommended for use with line driver type (source/
sink) outputs. When used with differential receivers, this combination provides a high
degree of noise immunity.
5. Output IC’s: Output IC’s are available as either Line Driver (LD) or NPN Open Collector
(OC) types. Open Collectors require pull-up resistors, resulting in higher output source
impedance (sink impedance is similar to that of line drivers). In general, use of a Line
Driver style output is recommended. Line Drivers source or sink current and their lower
impedance mean better noise immunity and faster switching times. Warning: Do not
connect any line driver outputs directly to circuit common/OV, which may damage the
2.03
driver. Unused outputs
should be isolated and left floating. Our applications specialists
would be pleased to discuss your system requirements and the compatibility of your
0.59
receiving electronics with Line Driver type outputs.
28V/V: Multi-voltage Line Driver (7272*): 100 mA source/sink. Input voltage 5 to 28 VDC
+/- 5% standard (Note: Vout = Vin). This driver is TTL compatible when used with 5 volt
supply. Supply lines are protected against overvoltage to 60 volts and reverse voltage.
Outputs are short circuit protected for one minute. Supply current is 120 mA typical (plus
load current). This is the recommended replacement for 3904R and 7406R open collector
outputs with internal pullup resistors. It is also a direct replacement for any 4469, 88C30,
8830 or 26LS31 line driver
28V/5: Multi-voltage Line Driver (7272*): 100 mA source/sink. Input voltage 5 to 28 VDC
+/- 5% standard, internally regulated with 5V (TTL compatible) logic out. Supply lines are
protected
against
overvoltage to 60 volts and reverse voltage. Outputs are short circuit
1/4-20
UNC-2B
protected
one minute.
Supply current is 90 mA typical (plus load current).
0.50forDEEP
(4) ON
A Multi-voltage
3.0 DIA B.C.
15V/V:
Line Driver (4469*): 100 mA source/sink. Input voltage 5 to 15
VDC +/- 5% standard (Note: Vout = Vin). TTL compatible when used with 5 volt supply.
Supply lines are protected against overvoltage to 60 volts and reverse voltage. Outputs
are short circuit protected for one minute. Supply current is 90 mA typical (plus load current). This is a direct replacement for the 4469 Line Driver.
28V/OC: NPN Open Collector (3904*, 7273*). Current sink of 80 mA max. Current
4.06
sourced by external pull- up resistor. Output can be pulled up to voltage other than supply
voltage (30 V max). Input voltage 5 to 28 VDC +/- 5% standard. Supply current is 120 mA
typical. This replaces prior IC’s with designations of 3904, 7406, 3302, 681 and 689.
5V/OCR, 15V/OCR, 24V/OCR: Open
Collector (3904R*, 7406R*, 7273R*): Current sink of
4.00
70 mA max. Includes internal pull-ups sized at approximately 100 ohms/volt. Max current
source is 10 mA. Supply current is 100 mA typical, 120 mA with internal pull-ups. The 5V/
OCR, 15V/OCR and 24V/OCR are often replaced by the 28V/V in system upgrades.
2.45 3904, 3904R, 4469, 5V/V, 5V/OC, 5V/OCR, 9V/OC: Intrinsically safe line driver and open
collector outputs. These drivers are specific to intrinsically safe encoders, and are installed per the
appropriate control drawings listed in Table 2.1 on page 48 of the 2008 BEI Specifying Guide.
6. Special
2.56–S at the end of the model number is used to define a variety of non-standard
features such as special shaft lengths, voltage options, or special testing. Please consult
the factory to discuss your special requirements.
7. Higher frequency response may be available. Please consult with the factory.
8. Extended temperature ratings are available in the following ranges:
-40 to 70°C, -40 to 85°C, –20 to 105°C and –40 to 105°C depending on the particular
model. Some models can operate down to
-55°C. Extended temperature ranges can affect other performance factors. Consult with
factory for more specific information.
9. Mating straight plug receptacles may be ordered from the factory:
For M12 use MS3116F12-10S, For M14 use MS3106F14S-6S
For M14/19 use MS3116J14-19S, For M16 use MS3106F16S-1S
For M18 use MS3106F18-1S, For M20 use MS3106F20-29S
* Products manufactured prior to April 2007 used the line driver IC number instead of­ voltage output in model number.
Tel: 805-968-0782 /800-350-2727 | Fax: 805-968-3154 / 800-960-2726 | 7230 Hollister Ave., Goleta, CA 93117-2807
www.beisensors.com
A B Z V G CG A B Z S
Similar pages