Schurter CGA0.6101.151 Iec appliance inlet c14 with filter, fuseholder 1- or 2-pole (5x20 mm or 6.3x32 mm), line switch 1- or 2-pole, voltage selector (series-parallel) Datasheet

CG
Power Entry Modules with Line Filter
www.schurter.com /PG06
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole (5x20 mm or 6.3x32 mm), Line Switch 1- or
2-pole, Voltage Selector (Series-Parallel)
Standard- or Medical-Filter
C14
70° C
Description
- Panel Mount :
Screw-on mounting from front side
- 5 Functions :
Appliance Inlet , Line Switch , Fuseholder with interchangeable fuse
drawer for Fuse-links 5x20 mm or 6.3x32 mm , Voltage Selector
(series-parallel) , Line filter in standard and medical version
- Quick connect terminals 4.8 x 0.8 mm
Approvals
- VDE Certificate Number: 40004665 (FKSA, FKSB)
- UL File Number: E72928 (FKSA, FKSB)
Characteristics
- All single elements are already partially wired
- For added safety "Extra-Safe" fuse drawers are available
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
References
Alternative: version without line filter KG
Alternative: Standard version
Weblinks
pdf-datasheet, html-datasheet, General Product Information, RoHS,
CHINA-RoHS, REACH, Distributor-Stock-Check, Accessories, Detailed
request for product
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 4.8 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Voltage Selector
Line Filter
MTBF
C14 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 or 6.3 x 32 mm
5 x 20: 2.5 W (1 pole)/ 2 W (2-pole) per
pole
6.3 x 32: 3.15 W (1 pole)/ 2.5 W (2-pole)
per pole
Admissible power acceptance at higher
ambient temperature see derating curves
2-pole, non-illuminated, acc. to IEC
61058-1
Technical Details
series-parallel, 4, 3 or 2 switch positions
or usable as 2-pole change-over switch
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 1'100'000 h acc. to MIL-HB-217 F
EMC Products
1
CG
Power Entry Modules with Line Filter
www.schurter.com /PG06
Dimension
CG
55
30
M3/ø 3.6
2
R 4.5
ø 3.2
R6
89 ±0.15
+0.3
0
81
79.7
89
97
230
ø 6.3x90˚
4.8x0.8
0
R 3 -0.2
56
R 3.1
2.8
69
27.2
28.5
+0.2
0
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MΩ]
1
Standard Version
2 x 10
68
2.2
-
2
Standard Version
2x4
68
2.2
-
4
Standard Version
2 x 1.5
68
2.2
-
6
Standard Version
2 x 0.8
68
2.2
-
10
Standard Version
2 x 0.3
68
2.2
-
1
Medical Version (M5)
2 x 10
68
-
1
2
Medical Version (M5)
2x4
68
-
1
4
Medical Version (M5)
2 x 1.5
68
-
1
6
Medical Version (M5)
2 x 0.8
68
-
1
10
Medical Version (M5)
2 x 0.3
68
-
1
Diagrams
Standard version
with fuseholder 1- or 2-pole
Medical version (M5)
with fuseholder 2-pole
A
L
L1
1)
Cx
L2
N
X)
F1
Cy
PE
3
Cy
PE’
5
Voltage
6
Selector
7
8
B
F2
4
X)
2)
L1
1)
PE
9
10
A
L
N
Cx
F1
L2
5
Voltage
6
Selector
7
8
B
x) external connection to be made by the customer
1) Line
2) Load
1) Line
2) Load
EMC Products
X)
PE’
R
x) external connection to be made by the customer
2
3
F2
4
X)
9
10
2)
CG
Power Entry Modules with Line Filter
www.schurter.com /PG06
Derating Curves
2.0
I = 1.0 In
1.5
I = 0.7 In
I = << In
1.0
0.5
0.0
0
20
40
60
80
100
Ambient air temperature Ta °C
2.0
1.5
I = 1.0 In
I = 0.7 In
1.0
I = << In
0.5
0.0
0
20
40
60
80
100
Ambient air temperature Ta °C
Fuses
6.3 x 32 mm (2-pole, per pole)
3.15
2.5
I = 1.0 In
2.0
I = 0.7 In
1.5
I = << In
1.0
0.5
0.0
0
20
40
60
80
100
Admissible power
acceptance in Watt
2.5
Fuses
6.3 x 32 mm (1-pole)
Admissible power
acceptance in Watt
Fuses
5 x 20 mm (2-pole, per pole)
Admissible power
acceptance in Watt
Admissible power
acceptance in Watt
Fuses
5 x 20 mm (1-pole)
Ambient air temperature Ta °C
Attenuation Loss
2.5
2.0
I = 1.0 In
1.5
I = 0.7 In
I = << In
1.0
0.5
0.0
0
20
40
60
80
100
Ambient air temperature Ta °C
- - - - 50Ω differential mode _____ 50Ω common mode
Standard version
1A
2A
4A
6A
2A
4A
6A
10 A
Medical version (M5)
1A
10 A
EMC Products
3
CG
Power Entry Modules with Line Filter
www.schurter.com /PG06
All Variants
Type
Rated Current
[A]
Filter-Type
Fuseholder
Line Switch
Line Switch
Order Number
CG
1
Standard Version
1-pole
2-pole
-
CG16.5101.151
CG
2
Standard Version
1-pole
2-pole
-
CG26.5101.151
CG
4
Standard Version
1-pole
2-pole
-
CG36.5101.151
CG
6
Standard Version
1-pole
2-pole
-
CG46.5101.151
CG
10
Standard Version
1-pole
2-pole
-
CG66.5101.151
CG
1
Standard Version
2-pole
2-pole
-
CG10.6101.151
CG
2
Standard Version
2-pole
2-pole
-
CG20.6101.151
CG
4
Standard Version
2-pole
2-pole
-
CG30.6101.151
█
CG
6
Standard Version
2-pole
2-pole
-
CG40.6101.151
█
CG
10
Standard Version
2-pole
2-pole
-
CG60.6101.151
█
CG
1
Medical Version (M5)
2-pole
2-pole
-
CGG0.6101.151
CG
2
Medical Version (M5)
2-pole
2-pole
-
CGA0.6101.151
CG
4
Medical Version (M5)
2-pole
2-pole
-
CGC0.6101.151
CG
6
Medical Version (M5)
2-pole
2-pole
-
CGE0.6101.151
CG
10
Medical Version (M5)
2-pole
2-pole
-
CGL0.6101.151
█ Most Popular.
Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/Stock-Check-SCHURTER
Suffix ".21" corresponds to the version with V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching
system prevents against accidental removal of the cordset.
Packaging unit
5 Pcs
Required Accessory
Description
Fusedrawer 1
Fusedrawer for Fuse Links 5x20 mm resp. 6.3x32 mm
5 x 20, 2-pole
4305.0001
5 x 20, 1-pole
4305.0006
6.3 x 32, 2-pole
4305.0011
6.3 x 32, 1-pole
4305.0016
...
Jumper Wire 1
Connection with Stranded Cable
4
Type A, 70 mm
0881.0074
Type A, 100 mm
0881.0075
Type B, 70 mm
0881.0076
Type B, 100 mm
0881.0077
EMC Products
█
CG
Power Entry Modules with Line Filter
www.schurter.com /PG06
Accessories
Assorted Covers
Rear Cover
0859.0109
Cord retaining kits
Cord retaining strain relief
Flat head, A
4700.0001
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
Appliance Outlet further types to CG
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4300-06
4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
4012
Connector further types to CG
...
Mating Outlets/Connectors shuttered
Power Cord Overview complete
VAC13KS, Overview, diverse Connector IEC C13, cord end:
VAC13KS
17.11.2016
Power Cord further types to CG
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
EMC Products
5
Similar pages