DB Lectro HG4519/012-2Z1A Automotive subminiature pcb twin relay Datasheet

HG4519
Automotive Subminiature PCB Twin Relay
FEATURES
Two indepandent relay installed in one package
Miniaturized structure, light weight
TYPICAL AUTOMOTIVE APPLICATIONS
Power antenna
Tilt lock wheel
Power window
Automatic door lock
Interval wiper
Automatic seat adjustment
Slide roof control
Immobilizers
CONTACT DATA
Mechanical
2 Form C (2Z)
30A
30A
AgNi0.15, AgSnOInO
See curve, Current dependent
30A
0.1A, 12VDC
107 ops.
Electrical
105 ops. see Note 3
Form
Max. Switching Current
Make
Break
Material
Max. Switching Voltage
Max. Continuous Current
Min. Load
Service Life
COIL DATA
Type
Standard
0.8W
Sensitive
0.6W
Coil Voltage
Code
Nominal
Voltage
(VDC)
Resistance
(Ω) ±10%
Must Operate
Voltage max.
(VDC)
Allowable Voltage
(VDC)
Must Release
Voltage min.
(VDC)
006
009
012
024
006
009
012
024
6
9
12
24
6
9
12
24
45
100
178
700
64
135
255
1000
2.9
4.4
5.8
11.6
3.5
5.2
6.9
13.8
12.6
19.0
25.3
51.0
15.0
22.5
30.0
60.0
0.40
0.60
0.80
1.60
0.50
0.75
1.00
2.00
CHARACTERISTICS
Operate Time
Release Time
Insulation Resistance
Dielectric Strength
Shock Resistance
Vibration Resistance
Drop Resistance
Power Consumption
Ambient Temperature
Weight
3 ms. typical
1.3 ms. typical
100 MΩ, at 500 VDC, 50%RH
500 Vrms, 1 min.
30 g, 6ms.
6g / 30g, 10 - 200 Hz
1 M height drop on concrete
Standard: 0.8W; Sensitive: 0.6W
-40 C to 85 C operating; -40 C to 125 C storage
10 g, approx.
ORDERING DESIGNATION
Example:
HG4519 /
Model
Coil Voltage Code
Contact Form
2Z: 2 Form C
Version
1: Sealed
Contact Material
Nil: AgNi10; A: AgNi0.15; C: AgCdO; S: AgSnOInO
Coil Sensitivity
Nil: Standard 0.8W; L: Sensitive 0.6W
012 -
2Z
1
A
L
HG4519
1/2
HG4519
REFERENCE CURVE
* Not consider temperrature rise caused by contact current.
OVERALL DIMENSIONS, MOUNTING HOLES AND WIRING DIAGRAM (mm)
Overall Dimensions
Mounting Holes (Bottom View)
Wiring Diagrams (Bottom View)
NOTES
1.
2.
3.
4.
5.
All parameters, unless otherwise specified, are measured at ambient temperature 23ºC.
Maximum make current refers to inrush current of motor load.
Electrical life obtained at motor load of locked rotor at 25A, 13.5VDC with operating frequency of 1 ops/sec.
Custom-made services available with operational quantity. Please let us know your special requirements.
Specifications subject to change without prior notice.
DB LECTRO INC. 3600 boul. Matte suite I Brossard Qc J4Y-2Z2
TEL: (450)-444-1424 FAX: (450)-444-4714
HG4519
2/2
Similar pages