UTC BTB16G-8-C-TA3-T 16a triac Datasheet

UNISONIC TECHNOLOGIES CO., LTD
BTB16
Preliminary
TRIAC
16A TRIACS

DESCRIPTION
The UTC BTB16 is a 16A triacs which can be operated in 4
quadrants, it uses UTC’s advanced technology to provide customers
with high commutation performances and voltage insulated tab, etc.
The UTC BTB16 is suitable for AC switching application and
phase control application such as fan speed and temperature
modulation control, lighting control and static switching relay, either in
through-hole or surface-mount packages.

SYMBOL

ORDERING INFORMATION
Ordering Number
Lead Free
Halogen Free
BTB16L-x-x-TA3-T
BTB16G-x-x-TA3-T

TO-220
Packing
Tube
SENSITIVITY AND TYPE
PART NUMBER
B
C
◎: Available

Pin Assignment
1
2
3
MT1 MT2
G
Package
VOLTAGE
600V
◎
◎
800V
◎
SENSITIVITY
TYPE
50mA
25mA
STANDARD
STANDARD
MARKING INFORMATION
PACKAGE
MARKING
TO-220
www.unisonic.com.tw
Copyright © 2014 Unisonic Technologies Co., Ltd
1 of 3
QW-R401-044.b
BTB16

Preliminary
TRIAC
ABSOLUTE MAXIMUM RATINGS
PARAMETER
RMS On-State Current (Full Sine Wave) TC=86°C
Non Repetitive Surge Peak F=50 Hz t=20ms
On-State Current (Full
F=60 Hz t=16.7ms
Cycle, TJ initial=25°C)
SYMBOL
IT(RMS)
RATINGS
16
UNIT
A
160
A
168
A
ITSM
2
I t Value for Fusing
tP=10ms
It
144
A2 s
Critical Rate of Rise of
On-State Current IG=2xIGT, F=120 Hz TJ=125°C
dI/dt
50
A/µs
tr≤100ns
Non Repetitive Surge Peak
tP=10ms TJ=25°C
VDSM/VRSM
VDRM/VRRM+100
V
Off-State Voltage
Peak Gate Current
tP=20µs
TJ=125°C
IGM
4
A
Average Gate Power Dissipation
TJ=125°C
PG(AV)
1
W
Operating Junction Temperature
TJ
-40~+125
°C
Storage Junction Temperature
TSTG
-40~+150
°C
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.

2
THERMAL RESISTANCES
PARAMETER
Junction to Ambient
Junction to Case (AC)

SYMBOL
θJA
θJC
RATINGS
60
1.2
UNIT
°C/W
°C/W
ELECTRICAL CHARACTERISTICS (TJ =25°C unless otherwise specified.)
FOR STANDARD TYPE (4 QUADRANTS)
PARAMETER
Gate Trigger Current
(Note 1)
Gate Trigger Voltage
Gate Non-Trigger
Voltage
Holding Current
(Note 2)
Latching Current
Critical Rate of Rise of
Off-State Voltage
(Note 2)
Critical Rate of Rise of
Off-State Voltage at
Commutation(Note 2)

SYMBOL
IGT
TEST CONDITIONS
VD=12V, RL=33Ω
I-II-III
IV
ALL
VD=VDRM, RL=3.3kΩ,
TJ=125°C
ALL
VGT
VGD
IH
IT=500mA
IL
IG=1.2IGT
C
MIN TYP
B
UNIT
MAX MIN TYP MAX
25
50
mA
50
100 mA
1.3
1.3
V
0.2
I-III-IV
II
0.2
V
25
50
mA
40
80
60
120
mA
mA
dV/dt
VD=67%VDRM, Gate Open,
TJ=125°C
200
400
V/µs
(dV/dt)c
(dI/dt)c=7A/ms, TJ= 125°C
5
10
V/µs
MIN
TYP MAX UNIT
1.55
V
0.85
V
25
mΩ
5
μA
2
mA
STATIC CHARACTERISTICS
PARAMETER
Peak On-State Voltage(Note 2)
Threshold Voltage(Note 2)
Dynamic Resistance(Note 2)
SYMBOL
TEST CONDITIONS
VTM
ITM=22.5A, tp=380μs
TJ=25°C
VTO
TJ=125°C
RD
TJ=125°C
IDRM
TJ=25°C
Repetitive Peak Off-State Current
VDRM=VRRM
IRRM
TJ=125°C
Note: 1. Minimum IGT is guaranteed at 5% of IGT max.
2. For both polarities of MT2 referenced to MT1.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
2 of 3
QW-R401-044.b
BTB16
Preliminary
TRIAC
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 3
QW-R401-044.b
Similar pages