ETC2 BPWX4-14-00 Bias power supply module bpwx 4 sery Datasheet

BIAS Power Supply Module
BPWX 4 Series Data Sheet
Single (Vo) or Dual (Vo & Vr) output
BPWX 4-08-00, -08-33, -08-50
BPWX 4-14-00, -14-33, -14-50
BPWX 4-24-00
The BPWX Power Supply Module is the ideal low EMI solution
for worldwide deployment of control applications in wireless/
M2M, lighting, sensing, smart building and power distribution,
especially where long range wireless operation or extended temperature is required.
A patented design incorporating a custom integrated circuit into a
small package (2.45 in3 [40.1 cm3]) the BIAS Module provides an
immediate “drop-in” solution, requiring no additional external
components.
Operating Specifications
•
•
•
•
•
•
•
Extended Temperature with NO DE-RATING!
(-40 to +85°C )
Universal Input (90-308 VAC, 50/60Hz)
Small Size—2.45 in3 [40.1 cm3]
Low no-load input power <30mW
Constant power mode (not current limit)
3000 VAC Isolation
EN 55022, Class B; FCC Part 15, Class B
Meets UL/CSA and EN Product Safety (ITE)
The characteristics of the main (Vo) and auxiliary (Vr) outputs
are different and each has application-specific benefits which
can provide high value to the system designer:
Electrical
Input Voltage Range
90 - 308 VAC (50/60Hz)
Input Surge Withstand
345V, < 30 sec
Output Power (Pmax)
4 W min. (60Hz)
3.33 W min. (50Hz)
Efficiency
≥ 70%
Output Vo (Peak)
8, 14 or 24 VDC nom. +/- 5%
Line / Load Regulation Vo (Peak)
+/- 1% Po < Pmax
Temperature Regulation Vo (Peak)
+/- 2% Po < Pmax
Ripple Vo (@120 Hz)
(@ 100 kHz)
1.75 V p:p
0.25 V p:p
For Vo = 8V, Ir out 160mA max, Io+Ir ≤ 500mA
For Vo = 14V, Ir out 70mA max, Io+Ir ≤ 285mA
For Vo = 24V, Vr not available
Output Vr, 5.0 volt (+/- 5%)
For Vo = 8V, Ir out 250mA max, Io+Ir ≤ 500mA
For Vo = 14V, Ir out 83mA max, Io+Ir ≤ 285mA
For Vo = 24V, Vr not available
No-load Consumption
30 mW typical @ Vin=120 VAC
Isolation
3000 VAC (meets UL / CSA & EN Product Safety)
Earth Leakage @ 120 VAC
•
Bias Power AC/DC power supplies are available with two
different types of outputs to fit your applications…
(@120VAC / 60 Hz / 25ºC unless otherwise specified)
Output Vr, 3.3 volt (+/- 5%)
Features:
< 10 uA
Short Circuit Protection
Continuous, Pin ≤ 0.7 w @ Vin = 120 VAC
Reliability @ 25° C, MIL HDBK-217F
> 500 Khr MTBF
Vo is a voltage-regulated output which has a constant power
mode instead of a conventional current limit. This output is
best suited as a source for isolated DC utility power, which may
be used directly or post-regulated with either a linear regulator
or a DC/DC converter. Vo is self protecting, cannot be overloaded and can be shorted indefinitely. So unlike design-yourown, or partially complete modules where significant design
margin is required to stay far away from current limit, there is
no need to oversize a Bias Power supply. The graceful transition from voltage regulation to constant power along with the
wide range of product ratings allows the designer to select a
supply tightly matched to the design load.
Vr is also a voltage-regulated output and is thermally protected
from overload. It has very low output ripple capable of driving
elements which require a low-noise, tightly-regulated supply.
In addition, Vr is supplied internally by Vo. This means that any
capacitance added to Vo can increase the hold-up time of Vr as
well.
*Note: maximum currents specified for constant voltage range
only. See V-I curve on page 2 for Vo in constant power range.
Thermal
Operating Temperature
-40 to +85o C
Operating Relative Humidity
0 – 95%, non-condensing
Storage Temperature
-40 to +105º C
Mechanical
Package Size (L x W x H)
1.91 x 1.31 x 0.98 inches [48.5 x 33.3 x 24.9
mm]
Safety
Safety Compliance
UL / EN 60950-1 2nd Ed. (CB Report Available)
EMI Emissions
EN 55022, Class B, FCC Part 15, Class B
www.biaspower.com
BPWX 4 Series Data Sheet, Page 1 of 2
Revised 11/02/2013
Specifications subject to change
BIAS Power Supply Module
BPWX 4 Series Data Sheet
Single (Vo) or Dual (Vo & Vr) output
BPWX 4-08-00, -08-33, -08-50
BPWX 4-14-00, -14-33, -14-50
BPWX 4-24-00
Part Number Designation
PIN
DESCRIPTION
L1
Input High
L2
Input Low
Part Number
Output Configuration
Vo
Vr
BPWX 4-08-00
Single output
8 VDC
N/A
N/C
No Connection
BPWX 4-08-33
Dual Output
8 VDC
3.3 VDC
BPWX 4-08-50
Dual Output
8 VDC
5.0 VDC
Vo
Output
BPWX 4-14-00
Single output
14 VDC
N/A
GND
Ground
BPWX 4-14-33
Dual Output
14 VDC
3.3 VDC
Vr
Vr Output
BPWX 4-14-50
Dual Output
14 VDC
5.0 VDC
BPWX 4-24-00
Single Output
24 VDC
N/A
N/C
No Connection
1.
Recommended Land Pattern, top view
2.
NOTES
Pins 0.031” [0.787 mm] round
Pins extend 0.125” [3.175 mm]
below stand-offs
Recommended Isolation,
V-I Curve (For Vo in Constant Power Range)
V - I, typical
12.00
Vo, volts
10.00
Constant Power Region
8.00
6.00
4.00
2.00
0.00
0
200
400
600
800
1,000
1,200
1,400
1,600
Io, mA
www.biaspower.com
BPWX 4 Series Data Sheet, Page 2 of 2
Revised 11/02/2013
Specifications subject to change
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
BIAS Power:
BPWX 2-24-33 BPWX 2-24-50 BPWX 4-05-00 BPWX 4-05-33 BPWX 4-08-00 BPWX 4-08-33 BPWX 4-08-50
BPWX 4-12-00 BPWX 4-12-33 BPWX 4-12-50 BPWX 4-14-00 BPWX 4-14-33 BPWX 4-14-50 BPWX 4-24-00
BPWX 4-24-33 BPWX 4-24-50
Similar pages