ETC C350KH21 Iec contactors & starter Datasheet

IEC Contactors & Starters
Freedom
34-313
March 2008
Accessories
Auxiliary Contacts
Contact Configuration Code
NEMA Sizes 00 – 2 — IEC Sizes A – K
The auxiliary contacts listed below are designed for installation on Freedom Series starters and contactors. Snap-on
design facilitates quick, easy installation.
These bifurcated design contact blocks, featuring silver
cadmium alloy contacts, are well suited for use in very low
energy (logic level) circuits.
This two-digit code is found on the auxiliary contact to assist
in identifying the specific contact configuration. The first
digit indicates the quantity of NO contacts and the second
indicates the quantity of NC contacts.
NEMA Sizes 3 – 8 — IEC Sizes L – Z
Table 34-398. Product Selection
Circuit
Contact
Configuration
Code Catalog Number
Price
U.S. $
Base Auxiliary Contacts — NEMA Sizes 3 – 5, IEC Sizes L – S
NO
NO-NC
10
11
NEMA Size 3
IEC Sizes L – N
NEMA Sizes 4 – 5
IEC Sizes P – S
C320KGS31
C320KGS32
C320KGS41
C320KGS42
Auxiliary Contacts — NEMA Sizes 3 – 5, IEC Sizes L – S
Catalog Number
Side Mounted
NO
NC
NO-NC Top Mounted
C320KGS20
C320KGS21
C320KGS22
Auxiliary Contacts — NEMA Sizes 6 – 8, IEC Sizes T – Z
Table 34-397. Selection Product
Contact
Configuration
Code Catalog
Number
1NO
1NO (Logic Level)
1NC
10
10
01
C320KGS1
C320KGS1L
C320KGS2
1NO-1NC
1NO-1NC (Logic Level)
2NO
2NO (Logic Level)
2NC
1NO-1NCI
1NO (EC)-1NC (LO)
1NCI
11
11
20
20
02
N/A
N/A
N/A
C320KGS3
C320KGS3L
C320KGS4
C320KGS4L
C320KGS5
C320KGS6
C320KGS7
C320KGS8
1NO
1NC
10
01
C320KGT1
C320KGT2
1NO-1NC
1NO-1NC (Logic Level)
2NO
2NC
1NO-1NCI
1NO (EC)-1NC (LO)
1NCI
11
11
20
02
N/A
N/A
N/A
C320KGT3
C320KGT3L
C320KGT4
C320KGT5
C320KGT6
C320KGT7
C320KGT8
3NO
2NO-1NC
1NO-2NC
3NC
4NO
30
21
12
03
40
C320KGT9
C320KGT10
C320KGT11
C320KGT12
C320KGT13
3NO-1NC
2NO-2NC
2NO-2NC (Logic Level)
1NO-3NC
4NC
3NO-1NCI
31
22
22
13
04
N/A
C320KGT14
C320KGT15
C320KGT15L
C320KGT16
C320KGT17
C320KGT18
2NO-1NCI-1NC
2NO-1NO (EC)-1NC (LO)
1NO-1NC-1NO (EC)-1NC (LO)
N/A
N/A
N/A
C320KGT19
C320KGT20
C320KGT21
Description
10
01
11
Price
U.S. $
Side Mounted
NO-NC
11
2NO-2NC 22
2NO-2NC 22
Size
Catalog Number
NEMA 8, IEC Z
NEMA 6 – 7
IEC T – X
C320KA5
C320KA6
C320KA8
For reference only — not part of Catalog Number. See above.
NO-NC occupies two positions — L2 and L3, or R2 and R3. See next
page.
Top Mounted
Base Auxiliary Contact
Cat. No. C320KGS42
Auxiliary Contact
Cat. No. C320KGS22
Note: NCI = Normally Closed early opening designed for use in
reversing applications. EC = Early Closing. LO = Late Opening.
For reference only — not part of Catalog Number. See above right.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
CA08102001E
For more information visit: www.eaton.com
34
IEC Contactors & Starters
Freedom
34-314
March 2008
Accessories
Auxiliary Contact Location
NEMA Sizes 3 – 8, IEC Sizes L – Z
NEMA Sizes 00 – 2, IEC Sizes A – K
The sketches below illustrate the maximum number of auxiliary contacts that can be assembled to a contactor and their
locations.
The sketches below illustrate the maximum number of auxiliary contacts that can be assembled to a contactor or starter
and their locations.
Table 34-399. Auxiliary Contacts
Catalog
Number
Size
AE16
A–K
AN16
Poles
Available Mounting Positions Enclosed
3
T1, L1
L1
00
0–2
3
3
T1, L1, R1
T1, L1
L1
L1
AE56
A–K
3
L1, R1
L1, R1
AN56
00 – 2
3
T1, T2
—
CE15
A–C
D–K
G–J
G–J
2–4
3
4
5
T1, L1, R1
T1, L1
T1, R1
T1
L1, R1
L1
—
—
CN15
00
0–2
1, 2
1, 2
2–4
2–3
4
5
T1, L1, R1
T1, L1
T1, L1
T1, L1
L1
L1
—
—
10A
20 – 60A
60A
60A
2–4
2–3
4
5
T1, L1, R1
T1, L1
T1, L1
T1, L1
L1
L1
—
—
CE55
A–K
3
L1, R1
L1, R1
CN55
00 – 2
3
T1, T2
—
CN35
Table 34-400. Auxiliary Contacts
Size
Available Mounting Positions NEMA Size 3, IEC Sizes L – N
R2, R3, L1, L2, L3
NEMA Sizes 4 – 5, IEC Sizes P – S
L2, L3, R1, R2, R3
NEMA Sizes 6 – 7, IEC Sizes T – X
R1
NEMA Size 8, IEC Size Z
L2, R2
Available positions on contactors or starters other than what is factory
installed.
L1
L2
L3
R3
Base Aux. Aux.
Aux. Cont. Cont.
Cont.
R2
R1
Aux. Aux. Base
Cont. Cont. Aux.
Cont.
Front
of Contactor
Left Side
of Contactor
Rear
Open Type
Rear
34
Note: A Base Auxiliary Contact must be added in position R1 before
additional auxiliary contacts can be mounted on NEMA Size 3 and
IEC Sizes L – N, or in L1 on NEMA Sizes 4 – 5 and IEC Sizes P – S.
Right Side
of Contactor
NEMA Sizes 3 – 5
IEC Sizes L – S
Available positions on contactors or starters other than what is factory
installed.
When a pneumatic timer is mounted on contactor, only side mounted
auxiliary contact positions are available. The solid-state timer, when
added, takes up side mounted auxiliary contact position.
L1
L1
R1
L1
T1
T1
T2
Top View
Top View
L1
NEMA Sizes 6 – 7
IEC Sizes T, U, V, W and X
R1
T1
R1
L1
R1
T1
T2
L1
R1
L2
R2
R1
NEMA Size 8
IEC Size Z
Front View
Front View
Non-reversing
Contactors and Starters
Reversing
Contactors and Starters
Figure 34-172. Auxiliary Contact Location
Figure 34-171. Auxiliary Contact Location
For more information visit: www.eaton.com
CA08102001E
IEC Contactors & Starters
Freedom
34-315
March 2008
Accessories
DC Magnet Coils
Non-reversing Kit Consists of:
■
1 Encapsulated DC magnet coil
■ 1 NCI or NO/NCI side mounted
auxiliary contact
When Ordering Specify
Conversion Kit for Field Assembly
■ Catalog Number
Note: These kits are supplied with a NO/
NCI side mounted auxiliary contact in
place of the NCI contact.
Factory Installed DC Coil
■ For factory installed DC magnet coil
on AC contactors or non-combination starters (open type only), substitute the Code Suffix from table
below for the magnet coil identifier
in the device Catalog Number.
EXAMPLE: For Size 0 AC contactor
with a 24V DC coil, change
CN15BN3AC to CN15BN3T1C.
■
2 Blue colored connection wires
■ 1 Instruction publication
Operation
These DC coil kits have separate pickup and seal windings. A special (side
mounted) early-break NCI auxiliary
contact is used to either disconnect the
pick-up winding or insert the seal
winding in series with the pick-up
winding, depending on the frame size
of the contactor. DC coil kits come in
two styles, a suffix 1 and a suffix 4. The
1 suffix contains only the special (side
mounted) early break NCI auxiliary
contact. The 4 suffix contains a NO
contact in the same package as the
special (side mounted) early-break NCI
auxiliary contact.
Application
■
Connect for separate control
Not for use with cover control
switch operators
■ Use twin break, heavy-duty pilot
devices
■ Designed for +10%, -20% rated voltage, continuous duty operation
■
Note: For NEMA Sizes 00 and 0 and IEC
Sizes A – F, contactors may utilize either
suffix 1 or 4 DC coil kits; starters may utilize
suffix 4 DC coil kits only. For NEMA Sizes 1
and 2 and IEC Sizes G – K, both contactors
and starters may utilize a suffix 4 DC coil kit
only.
On the above sizes only, when the
special auxiliary package is mounted
on the side of a contactor or starter,
no standard auxiliary contact may be
mounted on the same side.
Note: For NEMA Sizes 3 – 5 and IEC Sizes
L – S, the special coil NCI clearing contact is
an add-on auxiliary (must mount on a base
mount auxiliary contact; normally a 1NO).
This arrangement will normally account for
two of the three contact positions on the
side of each contactor or starter.
Table 34-401. Product Selection DC Magnet Coils
Contactor or
Starter Size
NEMA
Conversion Data
Volts
IEC
Complete Conversion Kit
Magnet Coil
Coil
Number
Amps
P.U./Seal
Watts
P.U./Seal
NCI
Interlock
Number
Catalog
Number
Price
U.S $
Factory Installed
Ship Wt. Code
Lbs. (kg) Suffix
Adder
U.S $
Non-reversing — Kit includes NCI Side Mounted Auxiliary Contact
00 and 0
CN35 – A, B, D
D15 Relays
A–F
12
24
48
120
9-2988-11
9-2988-12
9-2988-13
9-2988-14
6.4/.28
3.2/.14
1.6/.07
.64/.028
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
C320KGD1
C320KGD1
C320KGD1
C320KGD1
C335KD3R1
C335KD3T1
C335KD3W1
C335KD3A1
1.0 (.5)
R1
T1
W1
A1
A–F
12
24
48
120
9-2988-11
9-2988-12
9-2988-13
9-2988-14
6.4/.28
3.2/.14
1.6/.07
.64/.028
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
C320KGD2 C320KGD2 C320KGD2 C320KGD2 C335KD3R4
C335KD3T4
C335KD3W4
C335KD3A4
1.0 (.5)
R4
T4
W4
A4
1 and 2
CN35 – G
G–K
12
24
48
120
9-2990-1
9-2990-2
9-2990-3
9-2990-4
15.4/.42
7.7/.21
3.9/.11
1.5/.041
185/4.98
185/4.96
185/5.04
185/4.87
C320KGD5
C320KGD5
C320KGD5
C320KGD5
C335KD4R4
C335KD4T4
C335KD4W4
C335KD4A4
1.0 (.5)
R4
T4
W4
A4
3
CN35 – K
L–N
12
24
48
120
9-3002-1
9-3002-2
9-3002-3
9-3002-4
24/.40
12/.20
6.1/.097
2.5/.038
293/4.84
288/4.75
295/4.67
298/4.57
C320KGD3
C320KGD3
C320KGD3
C320KGD3
C335KD5R1
C335KD5T1
C335KD5W1
C335KD5A1
2.0 (.9)
R1
T1
W1
A1
4 and 5
CN35 – N, S
P–S
24
48
120
240
9-2026-4
9-2026-3
9-2026-2
9-2026-1
18/.22
9/.11
3.3/.05
1.7/.02
400/5.3
400/5.2
450/5.4
440/4.9
C320KGD3
C320KGD3
C320KGD3
C320KGD3
C335KA3T1
C335KA3W1
C335KA3A1
C335KA3B1
2.5 (1.1)
T1B
W1B
A1B
B1B
00 and 0
CN35 – A, B, D
D15 Relays
A–F
12
24
48
120
9-2988-1 9-2988-2 9-2988-3 9-2988-4 C320KGD1 C320KGD1 C320KGD1 C320KGD1 C335KD3R1 C335KD3T1 C335KD3W1 C335KD3A1 1.0 (0.9)
R1 T1 W1 A1 1 and 2
CN35 – G
G–K
12
24
48
120
9-2990-1 9-2990-2 9-2990-3 9-2990-4 C320KGD3 C320KGD3 C320KGD3 C320KGD3 00 and 0
CN35 – A, B, D
D15 Relays
Reversing
6.4/.28
3.2/.14
1.6/.07
.64/.028
15.4/.42
7.7/.21
3.9/.11
1.5/.041
76.8/3.36
76.8/3.36
76.8/3.36
76.8/3.36
185/4.98
185/4.96
185/5.04
185/4.87
R1 T1 W1 A1 These kits are supplied with a NO/NCI side mounted auxiliary contact in place of the NCI contact.
Kit does not include mechanical interlock or crossover wiring. Two NO/NCI top mounted auxiliary contacts are supplied for electrical interlocking.
Factory installed DC coils on NEMA contactors and starters include a NO/NC top mounted auxiliary contact on each contactor for electrical interlocking. On IEC contactors and starters, a NC top mounted auxiliary contact is supplied on each contactor for electrical interlocking.
Available factory assembled only.
Two required per reversing assembly.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
CA08102001E
For more information visit: www.eaton.com
34
IEC Contactors & Starters
Freedom
34-316
March 2008
Accessories
Remote Reset Module
(32A Overload Relay)
34
Table 34-404. Metal Mounting Plates — Approximate Dimensions and Shipping Weights
The C316RR remote reset module for
the C316F, C316S and C316U overload
relays allows remote resetting of
tripped (32A) overload relays by
means of an electrical solenoid attachment which mounts on the side of the
overload relay.
Table 34-402. Product Selection
Remote Reset Module
Operating Voltage
Catalog
Number
24V 50/60 Hz
110V 50/60 Hz
C316RR1U
C316RR1A
Price
U.S. $
Catalog
Number
Dimensions in Inches (mm)
C321MP1
C321MP2
C321MP3
C321MP4
C321MP5
2.00 (50.8)
2.56 (65.0)
1.80 (45.7)
2.56 (65.0)
1.77 (45.0)
3.88 (98.6)
5.05 (128.3)
6.60 (167.6)
8.08 (205.2)
4.63 (117.6)
1.50 x 3.38 (38.1 x 85.9)
2.00 x 4.50 (50.8 x 114.3)
6.07 (154.2) 2.00 x 7.63 (50.8 x 193.8)
4.27 (108.5) .2 (.1)
.4 (.2)
.7 (.3)
.6 (.3)
.3 (.1)
C321MP6
C321MP7
C321MP8
C321MP9
2.52 (64.0)
4.20 (106.7)
4.20 (106.7)
5.66 (143.8)
5.14 (130.6)
7.38 (187.5)
4.35 (110.5)
5.05 (128.3)
2.00 x 4.59 (50.8 x 116.6)
3.50 x 6.87 (88.9 x 174.5)
3.50 x 3.86 (88.9 x 98.0)
5.25 x 3.63 (133.4 x 92.2)
.4 (.2)
.8 (.4)
.5 (.2)
.8 (.4)
C321MP11
C321MP12
C321MP13
8.70 (221.0)
5.71 (145.0)
8.70 (221.0)
11.35 (288.3)
8.08 (205.2)
7.17 (182.1)
Metal Mounting Plates
Wide
High
Mounting
7.00 x 10.81 (177.8 x 274.6) 5.25 x 6.75 (133.4 x 171.5) 7.00 x 6.63 (177.8 x 168.4) Ship
Wt.
Lbs. (kg)
1.2 (.5)
.9 (.4)
.9 (.4)
2-hole mounting.
3-hole mounting.
3-Pole Top Mounted Fuse Block Kit
IEC Sizes A – K, NEMA Sizes 00 – 2
Field mount to Freedom Series starters
and contactors. Designed to save
space and reduce installation costs.
They provide short circuit protection
for branch circuits.
Table 34-403. For Use on IEC Style Contactors,
Starters and Overload Relays
Application
Catalog
Number
Contactors
IEC Sizes A – F
IEC Sizes G – K
C321MP1
C321MP2
Non-reversing Starters
IEC Sizes A – F
IEC Sizes G – K
C321MP3
C321MP4
Overload Relays 32A
75A
C321MP5
C321MP6
Reversing Starters
IEC Sizes A – F
IEC Sizes G – K
IEC Sizes L – N
C321MP7
C321MP12
C321MP11
Reversing Contactors
IEC Sizes A – F
IEC Sizes G – K
IEC Sizes L – N
C321MP8
C321MP9
C321MP13
Price
U.S. $
Table 34-405. Selection Product
Fuse Type
Catalog
Number
Class H
Class R
—
—
30A 250V
30A 250V
C350KH21
C350KR21
Class G
Class G
Class G
Class G
—
—
—
—
15A 300V
20A 300V
30A 300V
60A 300V
C350KG37
C350KG38
C350KG31
C350KG32
Class T
Class T
—
—
30A 300V
60A 300V
C350KT31
C350KT32
Class J
Class J
Type M
Class CC
—
—
—
—
30A 600V
60A 600V
30A 600V 30A 600V
C350KJ61
C350KJ62
C350KM61
C350KC63
Class T
Class T
—
—
30A 600V
60A 600V
C350KT61
C350KT62
Price
U.S. $
Type M fuse block not approved for branch circuit protection.
For use with DIN rail and base mounting
adapters listed on Page 34-309.
Discount Symbol (Remote Reset). . . . . . . . . 1CD7
Discount Symbol (Mounting Plates) . . . . . . 1CD1C
For more information visit: www.eaton.com
CA08102001E
IEC Contactors & Starters
Freedom
34-317
March 2008
Accessories
Mechanical Interlock and Reversing Kits
Solid-State Timers
Mechanical interlocks and reversing kits are designed for
field assembly of reversing contactors or starters from Freedom Series components. The Reversing Kits include a
Mechanical Interlock, stabilizer bar and a pre-cut, trimmed
and formed wire set. Auxiliary contacts, if required, must be
ordered separately. See Page 34-313.
Solid-State ON DELAY Timer — Side Mounted on Freedom Series
NEMA 00 – 2, IEC A – K and C25D, C25E and C25F Frame
This timer is designed to be wired in
SERIES with the load (typically a coil).
When the START button is pushed
(power applied to timer), the ON DELAY
timing function starts. At the completion
of the set timing period, timer and series
wired load will both be energized.
Table 34-408. Product Selection — Mounted Timer
Cat. No.
C321KM60B
Part No.
23-7165
Wire Set
Table 34-406. Reversing Kits (Horizontal Contactor Mounting Only)
NEMA Size
Application
IEC Size
Catalog
Number
00
0
1
2
3
A–C
D–F
—
G–K
—
C321KM60K14B
C321KM60K13B
C321KM60K15B
C321KM60K16B
C321KM60K17 —
—
4
5
—
L and M
N
—
—
P–S
C321KM60K21 C321KM60K18 C321KM60K19 C321KM60K20 C321KM60K44 Price
U.S. $
Timing Range
Catalog
Number .1 – 1.0 Seconds
1 – 30 Seconds
30 – 300 Seconds
5 – 30 Minutes
C320TDN1_
C320TDN30_
C320TDN300_
C320TDN2000_
Add operating voltage Suffix to Catalog Number. A = 120V, B = 240V,
E = 208V
Rated .5 ampere pilot duty – not to be used on larger contactors.
Terminal connections are quick connects only. Two per side.
Shorting Bar Kits
These kits provide phase-to-phase power connections of
contactors for field assembly. The kits include bus connections and mounting hardware. The shorting bars connect all
three phases of a single contactor.
Table 34-409. Product Selection
Description
Catalog
Number
NEMA Size 3, IEC Sizes L – N
NEMA Size 4, IEC Sizes P – S
NEMA Size 5
NEMA Size 6, IEC Sizes T and U
C321SB18
C321SB19
C321SB21
C321SB22
Kit includes (2) NC auxiliary contacts.
Table 34-407. Mechanical Interlock Only Application
Catalog
Number
Price
U.S. $
NEMA Size
IEC Size
Contactor
Mounting
00 – 2
A–K
Horizontal
C321KM60B
3
L–N
Horizontal
C321KM30
Price
U.S. $
Price
U.S. $
Pneumatic Timers — Top Mounted
3 to 4
N to P
Horizontal
C321KM43
4
P–S
Horizontal
C321KM40
4 to 5
—
Horizontal
C321KM45
4 to 6
S to T/U
Horizontal
C321KM80
5
—
Horizontal
C321KM50
Attachment mounts on top of any NEMA Size
00 – 2 or IEC Size A – K Freedom Series starter
or contactor (top mounted auxiliary contacts
can not be installed on device when timer is
used). Timer unit has 1NO-1NC isolated timed
contacts — circuits in each pole must be the same polarity.
Units are convertible from OFF to ON DELAY or vice-versa.
5 to 6
—
Horizontal
C321KM56
Table 34-410. Maximum Ampere Ratings
6
T and U
Horizontal
C321KM70
6 to 7
T/U to V – X
Horizontal
C321KM90
7
V, W and X
Horizontal
C321KM34
4 or 5 to 5
P – S to 5
Vertical
C321KM55
5 to 6
—
Vertical
C321KM65
6
T and U
Vertical
C321KM66
6 to 7
T/U to V – X
Vertical
C321KM67
Without cross-wiring.
For use with latest series product.
Description
Make
Break
Volts AC
120
240
480
600
30
3
15
1.5
7.5
.75
6
.6
Table 34-411. Product Selection
Timing Range
Catalog
Number
.1 to 30 Seconds
10 to 180 Seconds
C320TP1
C320TP2
Price
U.S. $
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
CA08102001E
For more information visit: www.eaton.com
34
IEC Contactors & Starters
Freedom
34-318
March 2008
Accessories
Locking Cover for Overload Relay — C306 Only
Transient Suppressor Kits
Snap-on transparent or opaque plastic panel for covering access port to the overload relay trip setting dial — helps prevent accidental or unauthorized changes to
trip and reset setting.
NEMA Sizes 00 – 2, IEC Sizes A – K
Table 34-412. Product Selection
Description
Min. Ordering Catalog
Qty. (Std. Pkg.) Number
34
Clear cover, no accessibility
50
C320PC3
Gray cover, no accessibility, with Auto
only nib
50
C320PC4
Gray cover, no accessibility, with Manual
only nib
50
C320PC5
Gray cover with FLA dial accessibility,
A, B, C, D positions an Auto only nib
50
C320PC6
Gray cover with FLA dial accessibility,
A, B, C, D positions and Manual only nib
50
C320PC7
Price
U.S. $
Cat. No.
C320TS2
These devices mount directly to the
coil terminals of Freedom Series contactors or starters NEMA Sizes 00 – 2,
IEC Sizes A – K and lighting contactors
10 – 60A. Reversing devices will
require two.
Control Circuit Fuse Block
Finger Protection Shields
These panel mounted
fuse holders, designed
for control circuit protection or other similar low
current requirements,
have extractor type fuse
caps. The Class CC rejection type fuses
(KTK-R) used in these holders are
intended for use with equipment
designated as being suitable for use
on systems having high available fault
currents. If branch circuit protective
device is 45A or greater, C320FBR fuse
kit may be required for control circuit
protection per NEC 430-72.
Snap-on shields for both contactors
and starters provide IEC Type IP20
Finger Protection. Prevents accidental
contact with line/load terminals.
Table 34-413. Product Selection
Type
Max.
Amperes
Catalog
Number
Fuse Holder
Only
15
30
C320FB C320FBR Price
U.S. $
A fuse is not supplied, but holder will
accept a Bussman Type KTK or KTK-R
(13/32" x 1-1/2") fuse, 600V maximum.
Includes a 5A, 600V KTK-R fuse.
DIN Rail Mounting Channel —
35 mm
Designed for DIN rail mounting of IEC
style contactors and starters.
Table 34-415. Product Selection
Application
Catalog
Number
NEMA Size 00,
IEC Sizes A – C
NEMA Size 0,
IEC Sizes D – F
C320LS1
Price
U.S. $
C320LS3
C320LS4
NEMA Size 1
Starters
Reversing Starters
C320LS5
C320LS6
NEMA Size 2,
IEC Sizes G – K
Starters
Reversing Starters
C320LS7
C320LS8
Table 34-417. Product Selection
Description
Coil Voltage
50/60 Hz Catalog
Number
Transient
Suppressor
24 – 120V
208 – 240V
277 – 480V
C320TS1
C320TS2
C320TS3
Price
U.S. $
Suppressor is compatible with coil voltages/
ranges as shown, 50 and 60 Hz.
NEMA Sizes 3 – 5, IEC Sizes L – S
C320LS2
NEMA Sizes 1 – 2,
IEC Sizes G – K
Contactors
Reversing Contactors
These kits limit high
voltage transients produced in the control
circuit when power is
removed from the contactor or starter coil.
There are three separate suppressors for
use on 24 – 120V, 208 –
240V or 277 – 480V coils
respectively.
This device mounts on
top of any side mounted
auxiliary contact on
Freedom Series NEMA
Sizes 3 – 5, IEC Sizes
L – S and lighting contactors 100 – 300A. It connects across
coil terminals on any 120V contactor
or starter magnet coil (reversing starters or contactors require 2).
Adapter to DIN Rail Mount
Limits high voltage transients produced in the circuit when power is
removed from the coil.
NEMA 1 – 2 and IEC G – K Contactors
Table 34-418. Product Selection
Designed to allow DIN rail mounting of
NEMA 1 – 2 and IEC G – K contactors.
Includes all hardware required to convert contactors from panel mounting
to 35 mm DIN rail mounting.
Description
Coil
Voltage
Catalog
Number
Transient
Suppressor
120V
C320AS1
Price
U.S. $
Table 34-416. Product Selection
Catalog
Number
Price
U.S. $
C320DN65
DIN Rail
Table 34-414. Product Selection
Description
Catalog
Number
1 Meter Length
MC382MA1
Price
U.S. $
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
For more information visit: www.eaton.com
CA08102001E
IEC Contactors & Starters
Freedom
34-319
March 2008
Accessories
DC/AC Interface Module
Adhesive Dust Cover
The Catalog Number
C320DC Interface
Module is an optically
isolated solid-state
switch which provides
a means of operating
AC coils with a 5 – 48V
DC control signal. It
Cat. No.
acts as a space saving
C320DC
interposing relay which
can switch a specified 50/60 Hz AC
source to the contactor or starter coil.
NEMA Sizes 00 – 2, IEC Sizes A – K
The module may be directly attached
to the coil terminals of any Freedom
Series contactor or starter — NEMA
Sizes 00 – 3, IEC Sizes A – N and lighting contactors 10 – 100A. It also has
provisions for DIN rail mounting.
This device mounts on the side of Freedom NEMA Size 00 – 2 and IEC Size A – K
contactors. One unit can be mounted on each side and carries UL, cUL and IEC ratings. The device is rated for resistive, inductive and lighting applications.
The module will operate coils within
the voltage ranges shown below.
These adhesive stickers come 25 to a
package and provide extra protection
from contaminants when applied to
the sides of Freedom NEMA Sizes
00 – 2 and IEC Sizes A – K. Adhesive
covers are easily applied to side opening where auxiliaries are not installed
DC Input: 5 – 48V DC ±10% at
mA nominal
■ AC Operating Voltage: 240V AC
max. (360 VA) ±10% 50/60 Hz
■ DC Operating Voltage: 30V DC max.
(5A)
■ AC Current Rating:
❑ 10A make (inrush)
❑ 1A break (sealed)
Table 34-421. Product Selection
Description
Catalog
Number
25 to a package
C320DSTCVR
Price
U.S. $
Add-On Power Pole Kit
NEMA Sizes 00 – 2, IEC A – K
Table 34-422. Product Selection — Add-On Power Pole Kit
UL Ampere Rating
Locked Lighting AC-1
Rotor Ballast
600V
Tungsten
115V 230V 240V
480V
IEC 947 Ampere Rating
AC-3
600V
AC-5a
AC-5b
480V
1NO
Power
Pole
Catalog
Number
1/2
12
18
C320PPD10
Inductive Resistive hp
600V
600V
1-Phase
Design Characteristics
■
and provide extra protection from
metal filings and other debris.
15
20
2
96
20
20
Price
U.S. $
Table 34-419. Controller Coil Voltage Ranges
Controller Catalog
Number Prefix
Controller Coil
Size or
Range
Rating
Volts AC
AE16, AE17, AE56,
AE57, CE15, CE55
A–F
G–K
L–N
24 – 240
48 – 240
110 – 240
AN16, AN56, CN15,
CN55
00 – 0
1–2
3
24 _ 240
48 – 240
110 – 240
CN35
10 – 30A
60A
100A
24 – 240
48 – 240
110 – 240
Table 34-420. Product Selection
Coil
Voltage
Catalog
Number
6V DC
9V DC
C320DC2V6
C320DC2V9
12V DC
24V DC
48V DC
C320DC2V12
C320DC2V24
C320DC2V48
Price
U.S. $
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
CA08102001E
For more information visit: www.eaton.com
34
Similar pages