ETC2 DI3DIN Panel meters and controllers ac ammeter or voltmeter Datasheet

Panel Meters and Controllers
AC Ammeter or Voltmeter
Type DI3-DIN AV1/AV5
• 3-dgt µP-based for AC currents or voltages
• Selectable CT/VT primary range
• DIN-rail mounting
• Degree of protection (front): IP 40
Product Description
Ordering Key
3-dgt µP-based meter with
double input for AC currents
or voltages. With 20 selectable CV/VT primary ranges.
Model
Range code
Measurement
Power supply
Setpoints
Options
The housing is for DIN-rail
mounting and ensures a
degree of protection (front) of
IP 40.
Type Selection
Range code
AV1:
AV5:
Supply Specifications
Power supply
1 A/100 V
Standard current/voltage
5 A/500 V
Standard current/voltage
See Range Table
AC supply
24 VAC, -15% +10%,
50/60 Hz
B:
48 VAC, -15% +10%,
50/60 Hz
C:
115 VAC, -15% +10%,
50/60 Hz
D:
230 VAC, -15% +10%,
50/60 Hz (standard)
Power supply on request
A:
1)
1)
Overload protection
Cont. Current:
Voltage:
For 1 s Current:
Voltage:
Accuracy
(@ 25°C ± 5°C, R.H. ≤ 60%)
Temperature drift
Display
Sampling rate
Indication
Max.
Min.
500 VAC range
Other ranges
Over range
Input range selection
Decimal point position
Power consumption
230 VAC, -15% +10%,
50/60 Hz (standard)
24 VAC, 48 VAC, 115 VAC,
-15% +10%, 50/60 Hz
(on request)
3.2 VA
1)
1)
Input Specifications
Rated input
DI3-DIN AV5AD0XX
General Specifications
5 A/500 VAC, 45 to 400 Hz
(1 A/100 VAC on request)
Operating temperature
Storage temperature
1.2 x rated input
1.2 x rated input
5 x rated input
2 x rated input
± 0.5% f.s., ± 1 dgt
± 350 ppm/ºC
7-segment LED, h 14.2 mm,
3 digits
1 time/s
999
000
Scalesuppressionupto5%f.s.
Scalesuppressionupto 3% f.s.
EEE
DIP-switch selectable
DIP-switch selectable
Specifications are subject to change without notice
Insulation reference voltage
Dielectric strength
Noise rejection
CMRR
EMC
Safety standards
Connector
Housing
Dimensions
Material
Degree of protection
Weight
Approvals
0° to 50°C (32° to 122°F)
(R.H. < 90% non-condensing)
-10° to 60°C (14° to 140°F)
(R.H. < 90% non-condensing)
300 V to ground
4000 V for 1 minute
rms
rms
100 dB, 40 to 60 Hz.
IEC 60801-2, IEC 60801-3,
IEC 60801-4 (level 2),
EN 50 081-1, EN 50 082-1
EN 61 010-1, IEC 61010-1,
VDE 0411
Screw-type
89 x 53.5 x 58.5 mm
(3-DIN modules)
ABS, self-extinguish.: UL 94 V-0
Front: IP 40
Approx 200 g
CE, CSA
1
DI3-DIN AV1/AV5
Range Table
Range
Connection
1A/100 V
5A/500 V
10 A
15 A
25 A
40 A
50 A
60 A
100 A
150 A
220 V
250 A
380 V
400 A
500 A/V
500 A
600 A/V
600 A
1000 A/V
1000 A
Direct 1A
Direct 5A
CT10/1 A
CT15/1 A
CT25/1 A
CT40/1 A
CT50/1 A
CT60/1 A
CT100/1 A
CT150/1 A
CT10/5 A
CT15/5 A
CT25/5 A
CT40/5 A
CT50/5 A
CT60/5 A
CT100/5 A
CT150/5 A
CT250/1 A
CT250/5 A
CT400/1 A
CT500/1 A
CT500/5 A
CT600/1 A
CT600/5 A
CT1000/1 A
CT1000/5 A
CT400/5 A
Direct 100 V
Direct 500 V
VT220/100 V
VT380/100 V
VT500/100 V
VT600/100 V
VT1000/100 V
Decimal point Resolution
position
Voltage drop Input imp. Range code
ammeters
voltmeters
999/99.9
9.99/999
9.99
99.9
99.9
99.9
99.9
99.9
99.9
999
999
999
999
999
999
999
999
999
999
999
1V
250 mV
1 V/250 mV
1 V/250 mV
1 V/250 mV
1 V/250 mV
1 V/250 mV
1 V/250 mV
1 V/250 mV
1 V/250 mV
1 MΩ
1 MΩ
V
AV1
AV5
AV1/AV5
AV1/AV5
AV1/AV5
AV1/AV5
AV1/AV5
AV1/AV5
AV1/AV5
AV1/AV5
AV1
AV1/AV5
AV1
AV1/AV5
AV1
AV5
AV1
AV5
AV1
AV5
1 MΩ
1 V/250 mV
1 MΩ
1 V/250 mV
1V
250 mV
1V
250 mV
1V
250 mV
1 MΩ
1 MΩ
1 MΩ
Dimensions (mm)
A
45
89
Front Panel Description
1 mA/0.1 V
10 mA/1 V
10 mA
100 mA
100 mA
100 mA
100 mA
100 mA
100 mA
1A
1V
1A
1V
1A
1 A/V
1A
1 A/V
1A
1 A/V
1A
1
53.5
49.5
58.5
1. Display
3-dgt (maximum read-out 999).
46
54.5
Alphanumeric indication by means of 7-segment display
for:
- Displaying of the measured value, over-range.
Wiring Diagrams
2
Power supply
4
5
6
7
8
1
2
3
Power supply
4
5
6
7
8
IN
V
3
NC
2
IN
1
IN
A
8
NC
7
V.T.
IN
V
6
NC
5
IN
A
Power supply
4
IN
3
NC
2
IN
V
1
NC
8
IN
7
IN
A
6
NC
5
Voltage measurements
Direct
C.T.
IN
V
Power supply
4
NC
3
IN
2
NC
1
IN
A
Current measurements
Direct
Specifications are subject to change without notice
Similar pages