ETC2 EFRP-S500 500w redundant power module Datasheet

EFRP-S500
500W Redundant Power Module
Features:
≧
High Efficiency 80%
0~45
℃ Working Temperature
Power Failure Alarm
PMBus Support
General Specification
Input Range: 100 to 240 VAC, +/-10%
Power Factor: > 0.95 minimum
Hold Up Time: 17ms @ 80% Load
Short Circuit Protection
Over Current Protection
Over Voltage Protection
No Load Operation
℃
MTBF >100,000 Hours@25
Operating Temperature: 0 to 45
℃
Operating Humidity: 20 to 90 %
EMI/RFI: CE, FCC class B
Safety: UL, TUV, CCC, CB, BSMI
Input and Output Characteristics
Input
Output
)
+5V
+12V
-12V Optional
+5VSB(Optional)
Max.Load
28A
32A
41A
0.5A
3A
Min.Load
0.1A
0.1A
0.5A
0A
0A
Frequency
Current
Load
100~240
47~63Hz
7~3.5A
VAC
(
+3.3V
Voltage
Note:
+3.3V and +5V combined output shall not exceed 200W
Ripple and Noise
Output
+3.3V
+5V
+12V
-12V(Optional)
5Vsb(Optional)
Load Regulation
±5%
± 5%
± 5%
± 10%
± 5%
Line Regulation
± 1%
± 1%
± 1%
± 1%
± 1%
Ripple & Noise
60mV
60mV
120mV
120mV
60mV
Mechanical
Outline Dimension: 82mm(W) x 40mm(H) x 250mm(D)
Outline Drawing