AIMTEC AMER120C-70170Z-P Up to 1700ma | ac-dc led driver Datasheet

Series AMER120C-Z
up to 1700mA | AC-DC LED driver
FEATURES:
•
•
•
•
•
Models
Single output
Model
AMER120C-70170Z
AMER120C-70170Z-P
AMER120C-70170Z-PD
AMER120C-60200Z
Accurate Constant Current Output ±3%
High Efficiency: Up to 91%
Active Power Factor Correction
UVLO, Short Circuit, Over Voltage
Adjustable output current: 50-100%
•
•
•
•
•
IP65/IP67 design for indoor/outdoor
Over Temperature Protection
Dimmable output current: 10-100%
Open circuit protection
5 Year Warranty
Max Output
Power (W)
Input Voltage
(VAC/Hz)
Output Voltage
Range (V)
Output Current
(A)
Efficiency
(%)
119
119
119
120
90-305/47-63
90-305/47-63
90-305/47-63
90-305/47-63
35-70
35-70
35-70
42-60
1.7
1.7
1.7
2
91
90.5
90
90
Model Nomenclature functional differences:
With Suffix “-PD”
With Suffix “-P”
Without Suffix
With manually adjustable 50-100% & fully dimmable 10-100% (0-10V/10PWM/Resistive) output current
Only with manually adjustable output current: 50-100%
Only with fully dimmable 10-100% (0-10V/10PWM/Resistive) output current
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Input Current
Inrush current <2ms
Conditions
Typical
90 VAC, full load
115 VAC, cold start
305 VAC, cold start




Leakage current
Maximum
No Load
Output Short
115 VAC, full load
277 VAC, full load
Input dissipation
Power Factor
Input Fuse
Units
1.6
45
75
0.75
3.0
10.0
0.98
0.92
Arms
1.5
1.0
Sec.
Sec.
A
mA
W
W
3.15A / 300V
115 VAC, full load
277 VAC, full load
Start-up Time
Output Specifications
Parameters
Current accuracy
Line regulation
Load regulation
Ripple & Noise
Output Current Ripple
Current Overshoot
Hold-up time (min.)
Minimum Load Voltage
Conditions
Typical
LL to HL
Full Output Voltage Range
±3
±1
±1
Full load, 16.7-20ms duration
LL to HL, full load at cold start, % of rated output current
Maximum
Units
4.5
%
%
%
V p-p
A p-p
%
ms
1.5
10
0.5
See Models Table Above
Isolation Specifications
Parameters
I/O Isolation Voltage
Isolation Resistance
www.aimtec.com
F 052.1e R3
Conditions
I/P – O/P
I/P – FG
O/P – FG
I/P – O/P, 500Vdc
Typical
>100MΩ
Tel: +1 514 620 2722
1 of 6
Rated
Units
3750
2000
500
VAC
VAC
VAC
VAC
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120C-Z
up to 1700mA | AC-DC LED driver
Isolation Capacitance
3800
pF
General Specifications
Parameters
Conditions
Switching frequency
Over Voltage protection
Short circuit protection
Open circuit protection
Over Temperature Protection
Operating temperature
Maximum case temperature
Warranty case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Potting material
IP Rating
Weight
Dimensions (L X W X H)
MTBF
Typical
Maximum
Units
130
KHz
V
75
Continuous, Hiccup mode, auto recovery
Continuous
Threshold – Shutdown Output
+106
Hysteresis – Auto Recovery
+90
With Derating over 60oC
-40 to +70
90
-40 to 73
-40 to +85
oC
oC
oC
oC
oC
0.03
oC
% / oC
95
% RH
Free Air Convection
Metal (Aluminum)
Polysiloxane
IP67
850
6.93 x 2.70 x 1.65 inches 176.0 x 68.7 x 42.0 mm
>400,000 hrs (MIL-HDBK-217F at +25°C)
g
Safety Specifications
Parameters
Standards
Electromagnetic Interference
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient / Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Electromagnetic Immunity Requirements Applies
to Lighting Equipment
Pin Definition
Wire
Pin
Blue
Brown
Yellow/Green
Red LED+
Black LEDRed
Black
AC-N
AC-L
FG
+V Output
-V Output
DIM+
DIM-
Input wire gauge #18
Output wire gauge #14
EN55015 / FCC Part 15, Class B
EN61000-3-2, Class B
EN61000-3-3
EN61000-4-2, 8kV Air, 4kV Contact, Level 3, Criteria A
EN61000-4-3, Test-RS Level 3, Criteria A
EN61000-4-4, Burst EFT Level 3, Criteria A
EN61000-4-5, Line to Neutral 4kV, Line/Neutral to FG 6kV
EN61000-4-6. Test-CS Level 3, Criteria A
EN61000-4-8, Test 3A/m, Criteria A
EN61000-4-11, Criteria B
EN61547
Block diagram
AC-L
LED+
1st LED
AC
LEDAC-N
DIM+
R
AC-N
www.aimtec.com
F 052.1e R3
LED
LED
Tel: +1 514 620 2722
2 of 6
DIM+
10V
0-10V
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120C-Z
up to 1700mA | AC-DC LED driver
Dimensions
Top View
320.0±20.0
12.60±0.79
7.4
5.0±1.0
30.3 0.29
0.20±0.04
4.0 1.19
0.16
35.0±2.0
1.38±0.08
163.0±1.5
6.42±0.06
320.0±20.0
12.60±0.79
159.0±1.0
6.26±0.04
30.0±2.0
1.18±0.08
10.0±1.0
0.39±0.04
68.7±1.0
2.70±0.04
7.4
0.29
4.0
0.16
4.0
0.16
12.7
0.50
150.0±0.5
5.91±0.02
175.4±1.0
6.91±0.04
12.7
0.50
Side View
Yellow/Green
42.0±1.0
1.65±0.0
4
Blue
Brown
150.0±0.5
5.91±0.02
175.4±1.0
6.91±0.04
Derating Graph
Free Air Convection
Safe Operating Area
www.aimtec.com
F 052.1e R3
Tel: +1 514 620 2722
3 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120C-Z
up to 1700mA | AC-DC LED driver
Case Temperature (TC ) vs. Life Time
Case temperature vs Life time
Lilfe time(Khours)
180
135
90
45
0
40
50
60
70
Case temperature (℃)
80
90
Efficiency Vs. Input Voltage & Output Voltage (Constant current mode)
www.aimtec.com
F 052.1e R3
Tel: +1 514 620 2722
4 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120C-Z
up to 1700mA | AC-DC LED driver
PF vs. Input Voltage & Output Voltage (constant current mode)
Output Current vs. Output Voltage
www.aimtec.com
F 052.1e R3
Tel: +1 514 620 2722
5 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMER120C-Z
up to 1700mA | AC-DC LED driver
Output Current vs. Resistive / 0-10V Dimming
Output Current vs.10V PWM Dimming
Percentage of rated output current
Output Current vs. 10V PWM Duty Cycle
115/230/277 VAC
120.00%
110.00%
100.00%
90.00%
80.00%
70.00%
60.00%
50.00%
40.00%
30.00%
20.00%
10.00%
0.00%
0
10
20
30
40
50
60
70
10V PWM Duty Cycle (%)
80
90
100
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R3
Tel: +1 514 620 2722
6 of 6
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only