Bel MAP40-3105G Rohs compliant Datasheet

The Bel Power Solutions MAP30/40/42 Series of power supplies
combines low cost and universal input in a board-only power solution
to meet commercial and industrial requirements. Full international
safety, EMI and ESD compliance ensure worldwide acceptance.
All units bear the CE Mark.
Fixed frequency operation simplifies system level operation. The
MAP30/40/42 Series is configured to the international standard 3 x 5
inch footprint. Input and output connections are made via popular
single-row Molex connectors. Single output models feature widerange output adjustability to meet a wide variety of standard and userspecific output voltage requirements.

Universal Input 85-264 VAC

Input Transient & ESD Compliance to EN61000-4-2/-3/-4

Meets EN55022 Conducted and Radiated Limits

Greater than 311,000 Hours MTBF

Remote Sense (MAP30, MAP42)

RoHS Compliant

CE Marked to Low Voltage Directive
MAP30/40/42 Series
2
MODEL 9
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAX OUTPUT
CURRENT
PEAK
OUTPUT
CURRENT 1
LINE
REGULATION
LOAD
REGULATION
RIPPLE &
NOISE 2
INITIAL SETTING
ACCURACY
MAP30-1005G
5V
4.7V to 5.8V
6A
8A 8
0.2%
±1%
1%
4.9V to 5.1V
MAP42-1005
5V
4.7V to 5.8V
8A
11A
0.2%
±1%
1%
4.9V to 5.1V
3
0.2%
1%
1%
11.9V to 12.1V
2.3/1.9A 3
0.2%
1%
1%
23.8V to 24.2V
3
MAP42-1012G
12V/15V
11V to 18V
3.4/2.7A
MAP42-1024G
24V/28V
23V to 29V
1.7/1.4A 3
PEAK
OUTPUT
CURRENT 4
LINE
REGULATION
3A
5A
2A
3.5A
MODEL 9
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT
+5V
4.7V to 5.5V
MAP40-3000G
+12V
Fixed
MAP40-3100G
MAP40-3101G
MAP40-3105G
MAP40-3500G
MAP40-3003G
4.6/3.7A
LOAD
REGULATION
RIPPLE &
NOISE 2
0.2%
2%
1%
4.9V to 5.1V
1%
3.5% 5
1%
11.5V to 12.5V
1%
-11.5V to -12.5V
1%
4.9V to 5.1V
1%
11.5V to 12.5V
-12V
Fixed
0.3A
0.5A
1%
+5V
4.75V to
5.25V
3A
5A
0.2%
+12V
2%
6
2%
5
INITIAL SETTING
ACCURACY
Fixed
2A
3.5A
1%
3.5%
-12V
Fixed
0.3A
0.5A
1%
2%
1%
-11.4V to -12.6V
+5V
4.75V to
5.25V
3A
5A
0.2%
2%
1%
4.9V to 5.1V
+24V
Fixed
1A
1.5A
1%
3.5% 5
1%
23.0V to 25.0V
-12V
Fixed
0.3A
0.5A
1%
2%
1%
-11.5V to -12.5V
+5V
4.7V to 5.8V
3A
5A
0.2%
2%
1%
4.9V to 5.1V
+12V
Fixed
2A
3.5A
1%
3.5% 5
1%
11.5V to 12.5V
-5V
Fixed
0.5A
1A
1%
2%
1%
-4.75V to -5.25V
+5V
4.7V to 5.8V
5A
6A
0.2%
2%
1%
4.9V to 5.1V
1%
11.5V to 12.5V
-11.4V to -12.6V
5
+12V
Fixed
1A
3.5A
1%
3.5%
-12V
Fixed
0.3A
0.5A
1%
2%
1%
+5V
4.7V to 5.8V
3A
5A
0.2%
2%
1%
4.9V to 5.1V
+15V
Fixed
1.5A
3A
1%
3.5% 5
1%
14.7V to 15.3V
1%
-14.3V to -15.7V
-15V
Fixed
0.2A
0.5A
1%
2%
6
MAXIMUM
OUTPUT
POWER
40 W 7
40 W 7
40 W 7
40 W 7
40 W 7
40 W 7
1
Peak ratings may be used as maximum output current with 100 Linear Feet per Minute (LFM) forced air cooling.
Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3 MAP42-1012G output currents are expressed as 12V/15V operation. MAP42-1024G output currents are expressed as 24V/28V operation.
4 Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.).
5 Quasi regulated output. See Regulation Curves for more information.
6 Requires a minimum load of 0.5A on V1 or 0.3A on V2.
7 Needs 170 LFM forced air cooling for use at 50°C ambient.
8 Needs 200 LFM forced air cooling for use at 50°C ambient.
9 Non-G models use lead solder exemption and are not recommended for new designs.
Xxx Model highlighted in yellow is not recommended for new designs.
2
[email protected]
MAP30/40/42 Series
PARAMETER
3
CONDITIONS / DESCRIPTION
MIN
MAP42
MAP30, MAP40
MAX
UNITS
85
90
NOM
264
264
VAC
63
Hz
Input Voltage - AC
Continuous input range
Input Frequency
AC input
47
Brown Out Protection
Lowest AC input voltage that regulation is maintained with full rated
loads.
85
VAC
Hold-up Time
Nominal AC Input Voltage (115VAC), full rated load.
15
ms
Input Current
90 VAC (40W load).
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Internally limited by thermistor, Vin = 264 VAC (one cycle), 25° C
Operating Frequency
Switching frequency of power supply (fixed frequency).
PARAMETER
CONDITIONS / DESCRIPTION
Efficiency
Full load @120 VAC
Minimum Loads
Single output models; MAP30, MAP42.
All multiple output models, see regulation graphs.
Ripple and Noise
Full load, 20 MHz bandwidth.
Output Power
Multiple output models with convection cooling.
40
Watts
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on, V1.
1
%
Regulation
Transient Response
23
25
MIN
NOM
30
kHz
MAX
UNITS
See Model Selection Chart.
Varies by output, total regulation includes: Line changes from 90132 VAC or 175-264, changes in load starting at 20% load and
changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only of multiple
output units).
See regulation graphs.
μs
500
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
20
PARAMETER
CONDITIONS / DESCRIPTION
MIN
MAP30-1005G, MAP42-1005
MAP42-1012G
MAP42-1024G
Main output only of multiple output units.
Fully protected against output overload and short circuit. Automatic
recovery upon removal of overload condition.
5.8
20.0
32.0
5.8
8
APK
Amps
1
Remote Sense
38
70% typical
Time required for initial output voltage stabilization.
Overload Protection
ARMS
0.0
Turn-on Delay
Overvoltage Protection
1.2
NOM
2
ms
MAX
UNITS
6.8
22.0
37.0
6.8
V
130
Total cable drop, single output models only.
Sec
%
250
mV
Power Fail Warning is not available for MAP80-1024G. The MAP80-1012G is an open collector output, capable of sinking 35 mA, maximum.
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2016 Bel Power Solutions & Protection
BCD.00563_AC
Asia-Pacific
+86 755 298 85888
MAP30/40/42 Series
4
PARAMETER
CONDITIONS / DESCRIPTION
MIN
Approved to the latest edition of the following standards;
Agency Approvals
UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd.
Input to Chassis
Dielectric Withstand Voltage
Input to Output (tested by manufacturer only)
FCC CFR title 47 part 15 sub-part B - conducted
Electromagnetic
EN55022 / CISPR 22 conducted (Note 1)
Interference
EN55022 / CISPR 22 radiated (Note 2)
Line to Line
Input Transient Protection
EN61000-4-5 Level 3
Line to Ground
Insulation Resistance
Leakage Current
PARAMETER
Altitude
Operating Temperature
UNITS
VDC
B
B
B
Class
1
2
kV
7
MΩ
MAP42,
MAP40-3100G/3001G/3105G/3500G
MAP30-1005G,
MAP40-3000G, MAP40-3003G
500
μA
750
CONDITIONS/DESCRIPTION
MIN
Operating
Non-operating
Derate linearly above 50°C by 2.5% per °C
to a maximum temperature of 70°C
MAX
2121
4242
Input to output
Per EN60950, 264VAC
NOM
At 100% load:
At 50% load:
Storage Temperature
NOM
MAX
UNITS
0
0
10k
40k
50
70
-40
85
°C
±0.03
%/°C
95
%RH
±0.02
ASL Ft.
°C
Temperature Coefficient
0°C to 70°C (after 15 minute warm-up)
Relative Humidity
Non-condensing
Shock
Operating, peak acceleration
20
G
Vibration
Random vibration, 10Hz to 2kHz, 3 axis
6
GRMS
5
14.25
13.75
13.25
12.75
+5V @ 5.0 Amps
12.25
+5V @ 3.0 Amps
+5V @ 1.0 Amps
11.75
+5V @ 0 Amps
11.25
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
12V OUTPUT CURRENT
Figure1. MAP40-3500G Typical Quasi Regulation Performance For +12V Output
[email protected]
MAP30/40/42 Series
5
13.5
13.0
12.5
12.0
+5V @ 3.0 Amps
+5V @ 1.8 Amps
11.5
+5V @ 0.6 Amps
+5V @ 0 Amps
11.0
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
12V OUTPUT CURRENT
Figure 2. MAP40-3000/3100/3105G Typical Quasi Regulation Performance For +12V Output
17.0
16.5
16.0
15.5
15.0
+5V @ 3.0 Amps
+5V @ 1.8 Amps
14.5
+5V @ 0.6 Amps
+5V @ 0 Amps
14.0
13.5
0
0.15
0.3
0.45
0.6
0.75
0.9
1.05
1.2
1.35
1.5
15V OUTPUT CURRENT
Figure 3. MAP40-3003G Typical Quasi Regulation Performance For +15V Output
J1
NEUTRAL
LINE
MAP30 J2
PIN 1
PIN 7
PIN 2 J3
SAFETY EARTH GROUND
(0.250" x 0.032" FASTON)
PIN 1
MAP40 J2
N/C
V1
V1
GND
GND
+Sense
-Sense
PIN 6
PIN 1
MAP42 J2
V2
V1
V1
GND
GND
V3
PIN 6
V1
V1
GND
GND
+Sense
-Sense
PIN 1
J1/J2 MATES WITH MOLEX (SERIES 2139 or SERIES 41695) .156" (4mm)
CENTER CRIMP TERMINAL HOUSING OR EQUIVALENT
Figure 4. Electrical Connectors
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
127.0 x 76.2 x see table below
5.0 x 3.0 x see table below
0.26
0.6
Dimensions
Weight
UNITS
mm
in
kg
lb
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2016 Bel Power Solutions & Protection
BCD.00563_AC
Asia-Pacific
+86 755 298 85888
MAP30/40/42 Series
6
SINGLE OUTPUT MODELS
MULTIPLE OUTPUT MODELS
Model
Height
Model
Height
MAP30-1005G
1.16" (29.5)
MAP40-3000G
1.16" (29.5)
MAP42-1005
1.25" (31.8)
MAP40-3003G
1.16" (29.5)
MAP42-1012G
1.25" (31.8)
MAP40-3100G
1.25" (31.8)
MAP42-1024G
1.25" (31.8)
MAP40-3101G
1.25" (31.8)
MAP40-3105G
1.25" (31.8)
MAP40-3500G
1.60" (40.6)
Table 1. MAP30/40/42 Series Height
.
.
Figure 1. Mechanical Drawing
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
[email protected]
Similar pages