Mean Well ERPF-400 400w single output switching power supply Datasheet

400W Single Output Switching Power Supply
ERPF-400
series
Bauar t gepruft
Sicherheit
egel ma ge
od
o s
be wac
g
www. tuv.com
ID 2000000000
■ Features
Universal AC input / Full range
(Withstand 300VAC surge input for 5 seconds)
Built-in active PFC function
High efficiency up to 91%
Design against rain splash
Protections: Short circuit / Overload / Over voltage/
■ Applications
LED strip lighting
LED channel letters
LED moving sign
Over temperature
Cooling by free air convection
LED indicator for power on
Low cost,high reliability
100% full load burn-in test
3 years warranty
■ Description
ERPF-400 series is a 400W single output enclosed type AC/DC power surply with the active PFC design.
It adopts an aluminum case and the interior is semi-potted, protecting the internal electronic components
from rain splash and dust. With the complete protection functions, ERPF-400 is suitable for the applications
such as outdoor LED channel letters, billboard, commercial signs, etc.
■ Model Encoding
ERPF - 400 - 24
Output voltage(12V/24V/48V)
Output wattage
Series name
File Name:ERPF-400-SPEC 2017-08-14
400W Single Output Switching Power Supply
ERPF-400
series
SPECIFICATION
ERPF-400-12
MODEL
12V
24V
48V
RATED CURRENT
30A
16.7A
8.3A
0 ~ 30A
0 ~ 16.7A
0 ~ 8.3A
360W
400.8W
398.4W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
10.8 ~ 13.2V
VOLTAGE TOLERANCE Note.3 ±1.0%
LINE REGULATION
±0.5%
21.6 ~ 26.4V
±1.0%
±0.5%
43.2 ~ 52.8V
±1.0%
±0.5%
LOAD REGULATION
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME
2000ms, 100ms/230VAC; 3000ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.)
10ms/230VAC; 10ms/115VAC at full load
VOLTAGE RANGE Note.4
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF≧0.95/230VAC, PF≧0.98/115VAC
89%
CURRENT RANGE
INPUT
Note.5
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
SHORT CIRCUIT
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
127 ~ 370VDC
90%
cold start 45A/115VAC, 90A/230VAC
<1mA / 240VAC
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13.8 ~ 16.2V
27.6 ~ 32.4V
55.2 ~ 64.8V
Protection type :Shut down O/P voltage, re-power on to recover
Shut down O/P voltage, recovers automatically after temperature goes down
-30 ~ +60℃ (Refer to output load derating curve)
20 ~ 90% RH non-condensing
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note.6)
EMC EMISSION
IEC/EN 60950-1,CCC GB4943.1-2011 approved
-30 ~ +85℃, 10 ~ 95% RH
±0.1%/℃ (0 ~ 35℃)
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH
Compliance to EN55022 (CISPR22) class A, GB9254 classA, GB17625.1; EN61000-3-2
EMC IMMUNITY
Compliance to EN61000-4-5;light industry level,criteria A
MTBF
DIMENSION
233.422Khrs min. MIL-HDBK-217F (25℃)
220.4*130*48mm (L*W*H)
1.1Kg; 9pcs / 11Kg / 0.63CUFT
PACKING
NOTE
91%
2.5A/230VAC 3A/115VAC
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OTHERS
ERPF-400-48
DC VOLTAGE
RATED POWER
OUTPUT
ERPF-400-24
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Please refer to “Static Characteristics".
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 450mm*450mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com).
File Name:ERPF-400-SPEC 2017-08-14
ERPF-400
400W Single Output Switching Power Supply
Mechanical Specification
Case No.230
200
series
Unit:mm
8.6
LED
+V
ADJ.
65
9
8
9.5
7
130
6
5
ψ8
4
8
3
20.4
2
3
1
Terminal Pin No. assignment :
5
40
Pin No.
1
2
3
Assignment
AC/L
AC/N
FG
Pin No.
Assignment Max mounting torque
4~6
DC OUTPUT +V
8Kgf-cm
7~9
DC OUTPUT -V
Block Diagram
fosc : 80KHz
EMI
FILTER
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
O.V.P.
FG
O.L.P.
O.T.P.
PWM&PFC
CONTROL
DETECTION
CIRCUIT
Derating Curve
Static Characteristics
100
100
80
75
65
50
LOAD (%)
LOAD (%)
60
40
20
-30
-10
0
10
20
30 35 40
AMBIENT TEMPERATURE (℃)
50
60
(VERTICAL)
50
25
90
100
150
200
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:ERPF-400-SPEC 2017-08-14
400W Single Output Switching Power Supply
ERPF-400
series
Installation
1.ERPF-400 is designed for outdoor application and should be installed in the place
with shelter.
2.ERPF-400 should be installed in an upright position,leaning forward,backward or
lay flat are not allowed
Faulty installation methods
Correct installation method
20cm
20cm
20cm
10m
20cm
3.For heat dissipation, at least 20cm installation distance around the PSU
should be kept, shown as below:
File Name:ERPF-400-SPEC 2017-08-14