Amphenol M30-08P-A-2-S General eastern differential pressure transmitter Datasheet

Modus M Series
General Eastern
Differential Pressure
Transmitters
The Modus M Series family of differential pressure
transmitters measure low pressures, and feature
a variety of analog signal outputs with low power
consumption. A wide selection of standard
pressure ranges and electrical ratings is available.
These transmitters feature no moving parts to
wear out, reliable long term stability, and are
virtually position insensitive. The Modus M Series
transmitters are typically used for monitoring
cleanroom pressures, HVAC, velocity pressures,
bubbler level systems, and leak detection; as well
as filter differential, draft, fume hood, and other
low pressure applications.
The transmitters are housed in a compact
heavy duty, gasketted, cast aluminum enclosure
designed to Type 4/IP 65. The die cast aluminum
enclosure incorporates a recessed neoprene
gasket to prevent ingress of moisture or dust. Wall
mounting holes are enclosed in the cast aluminum
box and concealed by the cover. The wall
mounting holes and the cover attaching screws
Amphenol
Advanced Sensors
are outside the gasketted area. Access to the
terminals is made through knockouts on the front
of the box. A choice of two knockouts and three
hole sizes is available to accommodate usage of
1/2 in (12.70 mm) conduit and metric sizes PG11
and PG13.
Pluggable terminal block connectors are provided
with captive wire protection and captive terminal
screws.
The Modus M Series includes the M30 Series:
• Two-wire
• DC Voltage In
• 4 to 20 mA out
The span or zero adjustment is performed with a
20 turn potentiometer for fine resolution.
The Modus M Series transmitters comply with
the European requirements of EMC Directive
2004/108/EC, LVD 2006/95/EC and PED 97/23/EC.
Operation
The pressure sensing element is a differential
capacitance cell for pressure measurements ranging
from 0.1 in to 5 in (3.04 mm to 127 mm) of water (25
kPa to 1.0 kPa), or piezoresistive (silicon) sensors for
pressure measurements ranging from 5 in (127 mm) of
water to 10 in (1.0 kPa to 2.5 kPa).
The capacitance cell is capable of sensing very low,
negative or differential pressures.
Standard Pressure Ranges
US Units
Pressure Code
Momentary
Overpressure
03E
04E
05E
06E 07E
08E
Pressure Range
Maximum Safe
0 to 0.300 in H20
0 to 0.500 in H20
0 to 1.00 in H20
0 to 2.00 in H20
0 to 3.00 in H20
0 to 5.00 in H20
20 inH2O
-
Metric Units, Millimeters of Water
Pressure Code
Pressure Range
Momentary
Overpressure
03M
04M
05M
06M 07M
08M
0 to 7.50 mm H20
0 to 10.00 mm H20
0 to 25.0 mm H20
0 to 50.0 mm H20
0 to 75.0 mm H20
0 to 100 mm H20
Maximum Safe
500 mm
-
A very lightweight, responsive diaphragm within the
cell deflects a small amount when a small pressure
is applied. This deflection results in a change in
capacitance which is then detected and amplified
electronically.
The piezoresistive sensor is a solid state device
designed in a Wheatstone bridge configuration. When
pressure is applied to the device, the resistance of the
bridge changes by a small amount. The output of the
bridge is ratiometric to the supply voltage, and a small
change in resistance is detected as a change in output
voltage.
Metric Units, Pascal
Pressure Code
Momentary
Overpressure
03P
04P
05P
06P
07P
08P
Pressure Range
Maximum Safe
0 to 75.0 Pa
0 to 100.0 Pa
0 to 250 Pa
0 to 500 Pa 0 to 750 Pa
0 to 1.00 kPa
5 kPa
-
M Series Specifications
2 mounting holes for
#8 (4 mm) maximum screw
Performance
Accuracy
2.4 in (60 mm)
mounting hole
±1% of Span (including non-linearity and hysteresis)
3.6 in
(90 mm)
0.6 in
(15 mm)
Calibration
0.26 in
(6.5 mm
Traceable to National Institute of Standards and
Technology (NIST)
4.0 in (102 mm)
mounting holes
4.54 in (115 mm
G11, PG13 or 1/2 conduit holes
Environmental
1.37 in
(35 mm)
Storage Temperature
1.35 in
(34 mm)
-20°F to 160°F (-30°C to 70°C)
Effect of Temperature on Span
±0.02%/°C
Operating Humidity Range
10% to 90% RH, non-condensing
Shock Resistance
10 G (11 ms)
Vibration Resistance
5 G to 50 Hz
Electrical Connectors
Polarized Euro-plug/connectors
Connections
Pluggable terminal block for wire, 14 to 26 AWG
Material
Glass filled polyester
Physical
Dimensions
3.56 in x 4.54 in x 2.18 in (90 mm x 115 mm x 55 mm)
Pressure Port
2.5 in
(63.5 mm)
Effect of Temperature on Zero
±0.05%/°C
1.2 in
(30.5 mm)
1.6 in
(40.5 mm)
32°F to 115°F (0°C to 45°C)
2.18 in
(55 mm)
Operating Temperature Range
High
Low
3.4 in (86.5 mm)
Material
Aluminum alloy #A380
Cover Screws
M4 stainless steel, non-magnetic
Finish
Black epoxy paint
Knockout
Choice of 2 holes. Knockout hole sizes 1/2 in (12.70 mm)
conduit, PG11 or PG13. Cable glands not included.
Pressure Port Connection
3/16 in (4.57 mm) diameter
Suitable for:
• 1/8 in (3.04 mm) ID Tygon™ or polyurethane tubing
0.11 in to 0.15 in (3 mm to 4 mm)
• 1/4 in (6.35 mm) OD polyethylene tubing 0.23 in
(6 mm)
Weight
1.27 lb (576 g) maximum
Integral filters at both ports. Measures differential, gage
pressure or vacuum. Suitable for air or inert gases.
M30 Specifications
Ordering Information
Two-wire, 4 to 20 mA output
M30
Electrical
Supply Voltage
11 to 32 VDC (see diagram below for maximum loop
resistance)
Protected against reversal of polarity. Output limited
to approximately 3.85 mA at low end of span and
approximately 27 mA at upper end of span.
Code Input Pressure (IP)
X
See standard pressure ranges tables on page 4
Code
Offset (O)*
A
1/4 offset
B
1/2 offset
0
none
Code Knockout Quantity (KQ)
1
One hole
2
Two holes
Code
Knockout Size (KS)
R
1/2 in (12.7 mm) conduit
S
PG 11
M30 1500
___ -
___ -
___ -
T
PG 13
___ Typical model number.
*If the measured differential pressure is expected to go from positive to negative, a
transmitter with offset (elevated zero) should be ordered.
ce
ist
an
Pressure excursion
0% to 100% of range, see standard pressure ranges tables on page 4
“A” 1/4 span offset. At zero differential pressure, the output signal is:
Re
s
Loop Resistance (W*
Three options are available:
“0” No offset. At zero differential pressure, the output signal is:
4 mA (4 to 20 mA range)
1000
M
ax
im
um
500
Operating
Region
• 8 mA (4 to 20 mA range)
0
0
10
20
30
40
Power Supply Voltage
*Loop resistance = wire resistance + receiver resistance
Pressure excursion
-33% to 100% of range see standard pressure ranges tables on page 4
“B” 1/2 span offset. At zero differential pressure, the output signal is:
• 12 mA (4 to 20 mA range)
Pressure excursion
-100% to 100% of range, see standard pressure ranges tables on page 4.
To order: Determine the positive pressure range. From standard pressure
ranges table on page 4, find the corresponding pressure code. Add the required
offset (none, A, or B).
Power Supply
For example, M30 05E A__, is a transmitter with a maximum range of 1 in of H2O at
20 mA and a minimum range of -0.33 in of H2O at 4 mA.
11 to 32 Vdc
Enclosure
Ground
Receiver
Wire
0 to 1050 W
Wire
Modus M30 Series schematic diagram
Amphenol
Advanced Sensors
www.amphenol-sensors.com
© 2014 Amphenol Corporation. All Rights Reserved. Specifications are subject to change without notice.
Other company names and product names used in this document are the registered trademarks or
trademarks of their respective owners.
AAS-920-293G-03/2014
Similar pages