CUI AE10-EW-S5 Dc-dc converter Datasheet

For more information, please visit the product page.
date
09/13/2017
page
1 of 7
SERIES: AE10-EW │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
10 watts
high operating temp -40 to +70°C
4,000 Vac isolation
extra wide input voltage 10:1
input voltage up to 1 kVdc
OVP protection
output short circuit protection
board mounted
EN 62109 approved
MODEL
input
voltage
output
voltage
range
(Vdc)
(Vdc)
min
(A)
AE10-EW-S5
100~1000
5
AE10-EW-S9
100~1000
AE10-EW-S24
100~1000
Notes:
output
current
output
power
ripple
& noise1
efficiency2
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
0
2.00
10
200
72
9
0
1.11
10
200
76
24
0
0.42
10
200
80
1. Measured at nominal input, 20 MHz bandwidth oscilloscope, with 10 µF electrolytic and 1 µF ceramic capacitors on the output.
2. Measured at 200 Vdc input voltage, full load.
3. All specifications are measured at Ta=25°C, humidity < 75%, nominal input voltage, and rated output load unless otherwise specified.
PART NUMBER KEY
AE10-EW - SXX
Output Voltage
Base Number
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: AE10-EW │ DESCRIPTION: DC-DC CONVERTER
date 09/13/2017 │ page 2 of 7
INPUT
parameter
conditions/description
min
operating input voltage
typ
100
current
at 200 Vdc
at 600 Vdc
at 1000 Vdc
inrush current
at 200 Vdc
at 600 Vdc
at 1000 Vdc
input fuse
1 A / 1000 Vdc (external)
max
units
1000
Vdc
75
25
16
mA
mA
mA
7
20
30
A
A
A
OUTPUT
parameter
conditions/description
maximum capacitive load
5 Vdc output model
9 Vdc output model
24 Vdc output model
min
voltage accuracy
typ
max
units
6,000
4,000
470
μF
μF
μF
±1
±2
%
line regulation
from low line to high line, full load
±0.5
±1
%
load regulation
from 0% to full load
±0.5
±1
%
delay time
from Vin = 0 V to 90% of rated ouptut voltage
1
s
switching frequency
temperature coefficient
75
at full load
±0.02
kHz
%/°C
PROTECTIONS
parameter
conditions/description
min
over voltage protection
5 Vdc output model
9 Vdc output model
24 Vdc output model
over current protection
automatic recovery
short circuit protection
continuous, automatic recovery
typ
max
units
7.5
12
28
Vdc
Vdc
Vdc
110
%
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output for 1 minute
min
typ
safety approvals
EN 62109
conducted emissions
CISPR22/EN55022, class A (external circuit required, see Figure 2)
radiated emissions
CISPR22/EN55022, class A (external circuit required, see Figure 2)
ESD
IEC/EN61000-4-2, contact ± 6kV/air ± 8kV, class B
radiated immunity
IEC/EN61000-4-3, 10V/m, class A
EFT/burst
IEC/EN61000-4-4, ± 4kV, class B (external circuit required, see Figure 2)
surge
IEC/EN61000-4-5, ± 2kV, class B (external circuit required, see Figure 2)
conducted immunity
IEC/EN61000-4-6, 10 Vr.m.s, class A
MTBF
as per MIL-HDBK-217F, 25°C
RoHS
2011/65/EU
4,000
300,000
cui.com
max
units
Vac
hours
For more information, please visit the product page.
CUI Inc │ SERIES: AE10-EW │ DESCRIPTION: DC-DC CONVERTER
date 09/13/2017 │ page 3 of 7
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curves
-40
70
°C
-40
105
°C
95
%
2000
m
storage temperature
storage humidity
typ
non-condensing
altitude
SOLDERABILITY
parameter
conditions/description
min
typ
max
units
hand soldering
for 3~5 seconds
350
360
370
°C
wave soldering
for 5~10 seconds
255
260
265
°C
parameter
conditions/description
min
typ
max
units
dimensions
70.00 x 48.00 x 23.50 [2.756 x 1.890 x 0.925 inch]
case material
black flame-retardant heat-proof plastic (UL94V-0)
MECHANICAL
weight
mm
95
MECHANICAL DRAWING
units: mm [inch]
tolerance: ±0.50[±0.020]
pin diameter tolerance: ±0.10[±0.004]
PIN CONNECTIONS
PIN
Function
1
NC
2
-Vin
3
+Vin
4
+Vout
5
-Vout
NC=no connection
Recommended PCB Layout
Top View
cui.com
g
For more information, please visit the product page.
CUI Inc │ SERIES: AE10-EW │ DESCRIPTION: DC-DC CONVERTER
date 09/13/2017 │ page 4 of 7
DERATING CURVES
Temperature Derating Curve
(100~150 Vdc input voltage)
Temperature Derating Curve
(150~1000 Vdc input voltage)
100
Output Load (%)
Output Load (%)
100
80
60
40
20
0
-40 -30
0
Ambient Temperature (°C)
60
40
20
0
-40
70
50
80
0
50
Ambient Temperature (°C)
70
Load vs. Input Voltage Derating Curve
(at 25°C)
Output Load (%)
100
80
70
60
40
20
0
100
200
Input Voltage (Vdc)
1000
EFFICIENCY CURVES
AE10-EW-S5 Efficiency Curve
Efficiency vs. Load Current
76
80
74
75
72
Efficiency (%)
Efficiency (%)
AE10-EW-S5 Efficiency Curve
Efficiency vs. Input Voltage
70
68
66
70
65
60
55
50
45
64
40
10
62
60
100 200
300
400 500 600 700 800
Input Voltage (Vdc)
900 1000
cui.com
20
30
40
50
60
70
Load Current (%)
80
90
100
For more information, please visit the product page.
CUI Inc │ SERIES: AE10-EW │ DESCRIPTION: DC-DC CONVERTER
date 09/13/2017 │ page 5 of 7
EFFICIENCY CURVES (CONTINUED)
AE10-EW-S9 Efficiency Curve
Efficiency vs. Load Current
82
85
80
80
Efficiency (%)
Efficiency (%)
AE10-EW-S9 Efficiency Curve
Efficiency vs. Input Voltage
78
76
74
72
70
65
60
55
50
70
68
100 200
75
300 400 500 600 700 800
Input Voltage (Vdc)
10
20
80
90
100
80
90
100
AE10-EW-S24 Efficiency Curve
Efficiency vs. Load Current
85
86
84
80
82
Efficiency (%)
Efficiency (%)
40
50
60
70
Load Current (%)
900 1000
AE10-EW-S24 Efficiency Curve
Efficiency vs. Input Voltage
80
78
76
74
72
75
70
65
60
55
70
100 200
30
300
400 500 600 700
Input Voltage (Vdc)
800
900 1000
cui.com
50
10
20
30
40 50 60 70
Load Current (%)
For more information, please visit the product page.
CUI Inc │ SERIES: AE10-EW │ DESCRIPTION: DC-DC CONVERTER
date 09/13/2017 │ page 6 of 7
APPLICATION CIRCUIT
Figure 1
NTC
FU S E
+ IN P UT
+ VI N
+ Vo
- V IN
- Vo
C1
C2
TVS RL
M OV
- IN PU T
Table 1
Vout
(Vdc)
Fuse
MOV
NTC
C1
(µF)
C2
(µF)
TVS
5
1 A / 1000 Vdc
S14K880
10D-11
1
220
SMBJ7.0A
9
1 A / 1000 Vdc
S14K880
10D-11
1
120
SMBJ12A
24
1 A / 1000 Vdc
S14K880
10D-11
1
68
SMBJ33A
EMC RECOMMENDED CIRCUIT
Figure 2
Table 2
Recommended External Circuit Components
F US E
+ I NP U T
MOV
- IN P U T
N TC
LD M
LC M
C3
R1
C4
R2
C5
R3
C6
R4
+Vin
- V in
+ Vo
C1
- Vo
C2
TV S RL
FUSE
1 A/1000 Vdc
MOV
S14K880
C3, C4, C5, C6
47 µF/400 Vdc
R1, R2, R3, R4
1 MΩ/2 W
NTC
10D-11
LDM
4.7 mH/0.38 A
LCM
10 mH
Note: See also Table 1.
Notes:
1. C1 is a ceramic capacitor used to filter high frequency noise.
2. C2 is electrolytic and is recommended to be high frequency and low resistance. For capacitance and current of the capacitor, refer to the datasheet provided by the
manufacturer. Capacitance withstand voltage derating should be 80% or above.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: AE10-EW │ DESCRIPTION: DC-DC CONVERTER
date 09/13/2017 │ page 7 of 7
REVISION HISTORY
rev.
1.0
description
date
initial release
09/13/2017
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Similar pages