PAIRUI LXB-50C Constant current led power supply Datasheet

2016-V1.0-1119
Specifications
Constant Current LED Power Supplies
LXB-50C Series, 50W
PAIRUI ELECTRONICS
No. 545 Museum Road
Yangzhou, Jiangsu
China 225009
Tel: 86 (514) 8279 1592
Fax: 86 (514) 8769 3159
2016
led power supplies
PRODUCT SPECIFICATION
LED Power Supplies for Indoor Use
LXB-50C SERIES, 50WATT, IP20 RATING
Features
3 Year Warranty
High Input Voltage Range: 200~240Vac
Constant Current Output Mode
Waterproof Rating IP20
Built-in Active Power Factor Correction
Class II Power, no FG
Short Circuit, and Over Temperature Protections
Applications
√
Panel Light
√
Down Light
√
Cabinet Light
√
Other Indoor used Lights
√
Recessed Light
Electrical
LX B 50 - C 700 ST
Strain ReliefSet
Output Current(mA)
Output Mode
C = Constant Current Mode
Output Power(W)
Input Voltage Range
B = 200-240Vac
Series Name
PAIRUI ELECTRONICS
www.pairuigroup.com
Updated 2016-V1.0-1119
Page:1/6
led power supplies
PRODUCT SPECIFICATION
Electrical
PartNumber
Nominal
Input Voltage
LXB50-C350
200-240VAC
LXB50-C500
Output Current
Output Voltage
No Load
Output Voltage
Ripple
Efficiency
Certificate
350mA(100-142V)
156V
50%
90%
CE
200-240VAC
500mA(70-100V)
110V
50%
90%
CE
LXB50-C700
200-240VAC
700mA(50-71V)
78V
50%
89%
CE
LXB50-C1050
200-240VAC
1050mA(33-48V)
52V
50%
88%
CE
NOTE: Other output models are may available on request.
PAIRUI ELECTRONICS
www.pairuigroup.com
Updated 2016-V1.0-1119
Page:2/6
led power supplies
PRODUCT SPECIFICATION
INPUT
PARAMETER
CONDITIONS
Input frequency
Input current
Full load, Vin=220Vac
Inrush current
Cold start, Vin=230Vac
Power factor(PF)
Full load, Vin=220Vac
Surge voltage
L-N
MIN
TYP
MAX
47
50
63
0.29
UNITS
Hz
A
35
A
0.96
2
KV
PAIRUI ELECTRONICS
www.pairuigroup.com
Updated 2016-V1.0-1119
Page:3/6
led power supplies
PRODUCT SPECIFICATION
OUTPUT
PARAMETER
CONDITIONS
Output current accuracy
MIN
TYP
MAX
UNITS
±5
%
Line regulation
Vin from 200Vac to 240Vac
3
%
Load regulation
Vout from min. to max.
3
%
Output current overshoot
Turning on
Turn-on delay time
Cold start, power on
1000
ms
Ripple
Please refer to below measuring
method
50%Io
mAp-p
THD
Output load≥60%
%
10
%
20
NOTE: The values are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with
0.1uF & 47uF parallel capacitor under ambient temperature 25℃ at rated input voltage and rated load.
Protection
Short circuit
In hiccup mode, it will recover automatically after fault condition is removed
Over
temperature
120℃-160℃
It will recover automatically after the temperature goes down
PAIRUI ELECTRONICS
www.pairuigroup.com
Updated 2016-V1.0-1119
Page:4/6
led power supplies
PRODUCT SPECIFICATION
Environment
PARAMETER
CONDITIONS
MIN
Ambient operating
temperature
Startup at rated voltage
Operating relative humidity
TYP
MAX
UNITS
-25
+70
℃
Non condensing
20
90
%
Storagetemperature
Humidity 10 ~ 95% RH
- 40
+ 80
℃
Maximum case temperature
Hot-spotoncase
+ 75
℃
MTBF
Fullload, 220Vac input, 25℃ambient
temperature
Waterproof rating
IP20
Dimension(LxWxH)
122.0 x 43.0 x 30.0mm
Weight
300g
230
Khrs
Safety/EMC
Safety
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, FCC Part 15 Class B, EN61000-3-2, EN61000-3-3,
EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
NOTE: Unless otherwise specified, all the above parameters are measured at ambient temperature of
25℃andVin=200Vac to 240Vac.
PAIRUI ELECTRONICS
www.pairuigroup.com
Updated 2016-V1.0-1119
Page:5/6
PRODUCT SPECIFICATION
led power supplies
Mechanical
30
43
122
Unit: mm
Electrical Curve
DERATING CURVE
100
90
Load(%)
80
70
60
50
40
30
-25 -15
0
10
20 30 40 50 60 70
Temperature(℃)
PAIRUI ELECTRONICS
www.pairuigroup.com
Updated 2016-V1.0-1119
Page:6/6
Similar pages