MPD MPO-60S Mpo-60s sery Datasheet

MPO-60S Series
Single Output, 60W
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 60W Output Power
• Universal 90-264 AC Input
• EN 60950 Approved (UL)
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
• Eight Standard Models
• Meets EN 55022 B
Inrush Current
• Meets EN 61000-4
• >200 kHour MTBF
Min.
Typ.
Max.
90
264
127
373
47
63
Meets EN 55022 Class B; FCC Class B
See Model Selection Guide
Cold Start, 115 VAC
32.0
Cold Start, 230 VAC
50.0
264 VAC
3.5
Universal
Input Voltage Range
Input Frequency
Input Filter
Input Current
• Compact 2 x 4 In Package
Conditions
Safety Ground Leakage Current
Units
VAC
VDC
Hz
A Pk
mA
Output
Parameter
Output Voltage/Current
Output Voltage Tolerance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Overload Protection
Conditions
Min.
Typ.
See Model Selection Guide
See Note 1
±1.0
Vin = Min to Max
±0.5
Iout = 10% to 100%
±1.0
See Note 2
±1.0
115 VAC
8
230 VAC 100
±0.05
Continuous (Autorecovery)
See Note 3
150
Max.
Conditions
Input to Output
500 VDC
Max.
Units
%
%
%
%
mSec
%/°C
%
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
EMI/RFI
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Fixed
EMC Compliance
Switching Frequency
Min.
3,000
Typ.
Units
VAC
1,000
M⍀
4,700
pF
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
66
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Size
Weight
Conditions
Min.
Typ.
Max.
0
+25
+50
-20
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
4.00 x 2.00 x 1.20 Inches (101.60 x 50.08 x 30.48 mm)
5.21 Oz (0.150 kg)
Reliability Specifications
Parameter
MTBF
Safety Standards
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
200
kHours
UL 1950, EN 60950
Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Model
Number
MPO-60S-03
MPO-60S-05
MPO-60S-09
MPO-60S-12
MPO-60S-138
MPO-60S-15
MPO-60S-24
MPO-60S-48
Input
Current (A)
115 VAC
230 VAC
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Voltage
(VDC)
Output
Current (A)
Rated
3.3
5.0
9.0
12.0
13.8
15.0
24.0
48.0
8.00
8.00
6.67
5.00
4.35
4.00
2.50
1.25
% Min.
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Max
Output
Power
Max
Output
Capacitance
(W)
(µF)
26
40
60
60
60
60
60
60
8,800
8,800
6,670
5,000
3,600
3,600
2,500
770
Efficiency
(%, Typ)
74
78
82
84
83
85
86
88
Derating Curve
Other Models Are Available. Contact The Factory For Details
Notes:
1. Output voltage tolerance is measured at nominal input and 60% load.
2. Output ripple is measured at 20 MHz bandwidth using 0.1 µF and 10 µF
capacitors connected in parallel as close to the power supply terminals
as possible.
3. Overload protection is provided by an internal “hiccup” circuit. The unit
recovers automatically when the fault condition is removed.
4. These units will operate at no load without damage. For most applications however, MPD recommends that a minimum load always be
used. Contact the factory for more information.
5. Each unit includes an input fuse (250V/2A). Since this fuse is not field
replaceable, it is recommended that an external fuse of the same size
be used on the input of the power supply for protection.
Mechanical Dimensions
Connections
Input Connector (CN1):
• Molex 5273-03A or equivalent (one pin removed)
• Mating Housing: Molex 5195-03 or equivalent
• Mating Terminal: Molex 5293 or equivalent
Pin
1
2
3
Function
AC-Neutral
Removed
AC-Line
Safety Ground:
The mounting holes marked “Use metal standoffs” should be
connected to the system earth ground via metal spacers or
a cable. The input side mounting hole marked “FG” provides
the safety earth ground for the unit. This connection should
be locked to prevent possible loosening. Connecting the
output side mounting hole improves EMI.
Output Connector (CN2):
• Molex 5273-04A or equivalent
• Mating Housing: Molex 5195-04 or equivalent
• Mating Terminal: Molex 5293 or equivalent
Pin
1
2
3
4
Function
+VOUT
+VOUT
-VOUT
-VOUT
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages