ETC2 H-5331 Hp5 cycl-flexâ® reset timer Datasheet

EAGLE SIGNAL brand
HP5 CYCL-FLEX® Reset Timer
Electric Timers
The high quality timer
that has become an
industry standard...
knob setpoint, cycle
progress pointer, pilot
light, and patented
plug-in housing
Also see Series HP5E
in Section 5 for SolidState Model
RECOGNIZED
6
The HP5 CYCL-FLEX® series timer is a high quality, synchronous motor
driven reset timer housed in the standard CYCL-FLEX® plug-in housing.
Dial
Minimum
Setting
APPROVED
Dial
Divisions
Repeat
Accuracy
18
15 Min.
5
30 Min.
30 Sec.
15 Sec.
±4.5 Sec.
1 Min.
1/2 Min.
■ Easily read and well-spaced calibrations
6
±9 Sec.
60 Min.
2 Min.
1 Min.
±18 Sec.
■ Red progress pointer displays remaining time interval
■ Pilot light indicates when timer motor is energized
7
150 Min.
4.5 Min.
2 Min.
±45 Sec.
8
5 Hr.
9 Min.
3 Min.
±1.5 Min.
■ Standard timers supplied with "power on" clutch operation
9
10 Hr.
20 Min.
10 Min.
±3 Min.
■ Optional reverse action clutch will not reset on power failure
10
30 Hr.
1 Hr.
1/2 Hr.
±9 Min.
■ 15 terminal ABS (UL rated 94V-0) molded housing has high impact
11
60 Hr.
2 Hr.
1 Hr.
±18 Min.
■ Knob adjustable time ranges - progress pointer for each
T
I
M
E
R
S
CERTIFIED
Time Ranges Cont.:
Sym.
■ 16 standard time ranges from 5 seconds to 60 hours
E
L
E
C
T
R
I
C
FM
®
®
■ Highly visible, calibrated dials (7.85 inch circumference)
resistance and will not support combustion
Reset Time: 1/2 second at max. setting
OPERATION
Voltage/Frequency: 120V (+10, -15%), 60 Hz
240V (+10, -15%), 60 Hz
Application of power to terminals 1, 2, and 11 energizes the clutch coil,
closes contacts 9-10 and 6-8, and starts the timing period. At time out,
contacts 4-3 close, 11-12 open, and the motor stops. The timer will
remain in this condition until power is removed from the clutch coil.
Contacts 6-7-8 and 9-10-C are instantaneous contacts and operate with
the application of power to the clutch coil. Contacts 3-4-5 and 11-12-A
operate at time out with contacts 3-4-5 operating prior to contacts
11-12-A.
Burden: Motor: 2.45 VA, 120 VAC
Clutch: 10.5 VA
Output Rating: 10 amps, resistive, 120 VAC
5 amps, resistive, 240 VAC
Electrical Lifetime: Contingent on load characteristics. Average contact
life at full load is 250,000 operations. At 1 amp load, switch life increases
to 5 million cycles. Inrush current should not exceed 10 amps.
Power On Response: 28 ms average pull-in
17 ms average drop-out
Temperature Range: 0˚ to 140˚F (-18˚ to +60˚C)
SPECIFICATIONS
Time Ranges:
Sym.
Dial
Minimum
Setting
Dial
Divisions
Repeat
Accuracy
17
5 Sec.
1/6 Sec.
.05 Sec.
±.05 Sec.
15
10 Sec.
1/3 Sec.
1/6 Sec.
±.05 Sec.
14
15 Sec.
1/2 Sec.
1/4 Sec.
±.08 Sec.
0
30 Sec.
1 Sec.
1/2 Sec.
±.15 Sec.
1
60 Sec.
2 Sec.
1 Sec.
±.3 Sec.
2
150 Sec.
4.5 Sec.
2 Sec.
±.75 Sec.
3
5 Min.
9 Sec.
3 Sec.
±1.5 Sec.
4
10 Min.
20 Sec.
10 Sec.
±3 Sec.
6.08 DANAHER SENSORS & CONTROLS
Vibration: Unaffected by 2.5G sinusoidal vibration magnitudes in both
directions of three perpendicular mounting axes imposed from 10 to
900 Hz
Approximate Weight: 2 lb. 14 oz.
Agency Approvals: UL Recognition E61735
UL Recognition 71726 (Feature 92 only)
CSA Certification LR26861
CSA Certification (Feature 92 only)
FM Approval 15030
RoHS
OPERATION
ENCLOSURES
Standard and Reverse Start
Instantaneous contacts 9-10-C and 6-7-8 operate directly with the
clutch offering different sequences of operation depending on the
control circuit configuration.
Delayed contacts 4-3 and 11-A close and contacts 4-5 and 11-12
open when timer reaches a timed out condition. Contacts 4-5 and
11-12 close and contacts 4-3 and 11-A open when timer is reset.
Schematic Diagram
1
Model No.
NEMA Class
HN308
HN364
HN368
1
1
!A
HN370
1A
Description
Surface Mtg. with terminal block
Surface Mtg. without terminal block
Dual unit cabinet with 9 position
terminal block, timer housings, and
DPST toggle switch
Dual unit cabinet less unit cases and
toggle switch, with 9 terminal block
2
ACCESSORIES
M
Model No.
A
11
H-5331
HP50-31
HP50-103
10
12
9
3
C
4
8
6
HP50-131
HP50-133
HP50-295
5
7
Description
Mounting Brackets 2 req'd per timer
One Hole Mounting Ring
120 VAC, 50/60 Hz Repeat Cycle Kit
Not applicable with Feature 19
CYCL-FLEX® Water-Sealed Housing
Surface Mounting Adapter to use in place of brackets
Dial Lock
MOUNTING
DRILL AND TAP FOUR
HOLES FOR 8-32 SCREWS
(INCLUDED W/UNIT)
3.187 + .062
(80.95 + 1.57)
DIA. CUTOUT
1.406
(35.71)
4.250
(107.95)
3.062
(77.77)
1.406
(35.71)
1.406
(35.71)
MTG. HOLE
USED FOR
GROUNDING
CASE
1.406
(35.71)
3.812
(96.82)
4.125
(104.78)
1.625
(41.27)
5.750
(146.05)
ORDERING INFORMATION
HP5
15
A6
TIME RANGE
Sym.
01
FEATURES
Description
Sym.
Description
17
0-5 Sec.
18
0-15 Min.
15
0-10 Sec.
5
0-30 Min.
14
0-15 Sec.
6
0-60 Min.
0
0-30 Sec.
7
0-150 Min.
1
0-60 Sec.
8
2
0-150 Sec.
3
4
Sym.
VOLTAGE &
FREQUENCY
Sym.
Description
0-5 Hr.
A6
120V, 60 Hz
9
0-10 Hr.
B6
240V, 60 Hz
0-5 Min.
10
0-30 Hr.
0-10 Min.
11
0-60 Hr.
Description
01
Reverse Clutch Arrangement
07
Dial Lock
19
Revision for Mtg. to HN383 Explosion Proof
Cabinet. Add when purchased without
cabinet. DOES NOT have pilot light.
22
Water Resistant Window & Housing
92*
Enclosed in HN383 Explosion Proof Cabinet
*Laboratory Testing: UL Recognition E61735
CSA Certification LR45132-1