IRF M3G700515T Hybrid-high reliability radiation hardened dc-dc converter Datasheet

PD-94533P
M3G-SERIES
70V Input, Triple Output
HYBRID-HIGH RELIABILITY
RADIATION HARDENED
DC-DC CONVERTER
Description
The M3G-Series of DC-DC converters are radiation hardened,
high reliability converters designed for extended operation
in hostile environments. Their small size and low weight
make them ideal for applications such as geostationary earth
orbit satellites and deep space probes. They exhibit a high
tolerance to total ionizing dose, single event effects and
environmental stresses such as temperature extremes,
mechanical shock, and vibration.
The converters incorporate a fixed frequency single ended
forward topology with magnetic feedback and an internal
EMI filter that utilizes multilayer ceramic capacitors that are
subjected to extensive lot screening for optimum reliability.
By using two stage filtering these converters produce low
input and output noise. External inhibit and synchronization input
and output allow these converters to be easily incorporated into
larger power systems. They are enclosed in a hermetic
3" x 2" x 0.475" package constructed of an AluminumSilicon-Carbide (AlSiC) base and an Alloy 48 ring frame
and they weigh less than 110 grams. The package utilizes
rugged ceramic feed-through copper core pins and is
sealed using parallel seam welding.
Manufactured in a facility fully qualified to MIL-PRF-38534,
these converters are fabricated utilizing DLA Land and
Maritime qualified processes. For available screening options,
refer to device screening table in the data sheet.
Non-flight versions of the M3G-Series converters are available
for system development purposes. Variations in electrical
specifications and screening to meet custom requirements can
be accommodated.
1
M3G
Features


















Total Dose > 200 kRads(Si)
typically usable to > 300 kRads(Si)
SEE Hardened to LET up to 82 MeV.cm2/mg
Low Input & Output Noise
Low Weight < 110 grams
Magnetically Coupled Feedback
60V to 120V DC Input Range
Up to 40W Output Power
Triple Output Models Include
+5V and ±12V or ±15V
Main Output Isolated from Dual Outputs
High Efficiency - to 82%
-55°C to +125°C Operating Temperature Range
100M @ 500VDC Isolation
Under-Voltage Lockout
Synchronization Input and Output
Short Circuit and Overload Protection
Output Over Voltage Limiter
External Inhibit
> 5,000,000 hour MTBF
Applications



Geostationary Earth Orbit Satellites (GEO)
Deep Space Satellites / Probes
Strategic Weapons and Communication System
2016-06-30
M3G-SERIES
(70V Input, Triple Output)
Circuit Description
The M3G-Series converters utilize a single-ended forward
topology with resonant reset. The nominal switching frequency
is 500 kHz.. Electrical isolation and tight output regulation are
achieved through the use of a magnetically coupled feedback.
Voltage feed-forward with duty factor limiting provides high
line rejection.
An internal EMI filter reduces the conducted emissions to
less than 5mArms on the input power leads. A two stage
output filter reduces the typical output ripple to less than
20mV peak-to-peak.
The main (+5 volt) output is regulated by the control loop
and typically exhibits better than 1% regulation. The auxiliary
(±12 volt or ±15 volt) outputs are maintained through tight
coupling in the power transformer and main output filter
inductor and typically exhibit better than 5% regulation.
The main output and auxiliary outputs are isolated from
each other.
Output current is limited under any load fault condition to
approximately 125% of rated. An overload condition causes
the converter output to behave like a constant current
source with the output voltage dropping below nominal.
The converter will resume normal operation when the load
current is reduced below the current limit point. This protects
the converter from both overload and short circuit conditions.
The current limit point exhibits a slightly negative temperature
coefficient to reduce the possibility of thermal runaway.
An under-voltage lockout circuit prohibits the converter
from operating when the line voltage is too low to maintain the
output voltage. The converter will not start until the line
voltage rises to approximately 58 volts and will shut down
when the input voltage drops 54 volts. The four volt of hysteresis reduces the possibility of line noise interfering with
the converter’s start-up and shut down.
An external inhibit port is provided to control converter
operation. The nominal threshold relative to the input
return (pin 2) is 1.4V. If 2.0 volts or greater are applied
to the Inhibit pin (pin 3) then the converter will operate
normally. A voltage of 0.8V or less will cause the converter to
shut-down. The pin may be left open for normal operation
and has a nominal open circuit voltage of 4.0V.
Synchronization input and output allow multiple converters to
operate at a common switching frequency. Converters
can be synchronized to one another or to an externally
provided clock. This can be used to eliminate beat frequency
noise or to avoid creating noise at certain frequencies for
sensitive systems.
Design Methodology
The M3G-Series was developed using a proven conservative
design methodology which includes selecting radiation
tolerant and established reliability components and fully
de-rating to the requirements of MIL-STD-975 and MILSTD-1547 except for the CDR type ceramic capacitors, a
capacitor with 50V rating is used for in-circuit voltage
stress of less than 10V. Careful sizing of decoupling
capacitors and current limiting resistors minimizes the
possibility of photo-current burn-out. Heavy de-rating of
the radiation hardened power MOSFET virtually eliminates the
possibility of SEGR and SEB. A magnetic feedback circuit is
utilized instead of opto-couplers to minimize temperature,
radiation and aging sensitivity. PSPICE and Rad SPICE
were used extensively to predict and optimize circuit
performance for both beginning and end-of-life. Thorough design
analyses include Radiation Susceptibility (TREE), Worst Case,
Stress, Thermal, Failure Modes and Effects (FMEA) and Reliability (MTBF).
.
2
2016-06-30
M3G-SERIES
(70V Input, Triple Output)
Specifications
Absolute Maximum Ratings
Input voltage range
Recommended Operating Conditions
-0.5VDC to +150VDC
Output power
Internally limited
Lead temperature
Operating temperature
Storage temperature
Input voltage range
+60VDC to +120VDC
1
+60VDC to +100VDC
Input voltage range
+300°C for 10 seconds
-55°C to +135°C
-55°C to +135°C
0 to Max. Rated
Output power
Operating temperature
Operating temperature1
1
2
2
-55°C to +125°C
-55°C to +70°C
Meets de-rating per MIL-STD-975
For operation at +125°C see table note 15
Electrical Performance Characteristics
Parameter
Input voltage
Group A
Subgroup
Conditions
-55°C TC  +85°C
VIN = 70V DC ± 5%, CL = 0
unless otherwise specified
1,2,3
Note 2
Output voltage (VOUT)
(main)
M3G700512T (aux.)
M3G700515T (aux.)
(main)
M3G700512T (aux.)
M3G700515T (aux.)
Output power (POUT)
1
IOUT = 100% rated load, Note 5
Output current (IOUT)
(main)
M3G700512T (aux.)
M3G700515T (aux.)
Line regulation (VRLINE )
(main)
M3G700512T (aux.)
M3G700515T (aux.)
Load regulation (VRLOAD )
(main)
M3G700512T (aux.)
M3G700515T (aux.)
1,2,3
Min
Nom
Max
60
70
100
4.98
5.00
5.02
±11.50 ±11.80 ±12.10
±14.60 ±14.90 ±15.20
Unit
V
V
4.93
±11.30
±14.40
5.07
±12.30
±15.40
VIN = 60, 70, 100 Volts, Note 2
0
40
W
VIN = 60, 70, 100 Volts, Notes 2,3,4,5
400
83
67
4000
±833
±667
mA
-10
-120
-150
10
120
150
-50
-400
-500
50
400
500
-3.5
-3.0
2,3
1,2,3
Limits
1,2,3
VIN = 60, 70, 100 Volts
IOUT =10%, 50%, 100% rated
Note 5, 14
1,2,3
IOUT = 10%, 50%, 100% rated
VIN = 60, 70, 100 Volts
Notes 5,13
Cross regulation (VRCROSS)
M3G700512T (aux.)
M3G700515T (aux.)
1,2,3
VIN = 60, 70, 100 Volts
IOUT = 2.5A to 1A and 2.5A to 4A on main
and ±half rated on aux. outputs
Input current (IIN)
1,2,3
IOUT = 0, Pin 3 open
Pin 3 shorted to pin 2
35
2.0
3.5
3.0
50
5.0
1,2,3
VIN = 60, 70, 100 Volts
25
30
30
50
60
75
mVp-p
1,2,3
Sync. Input (Pin 4) open
500
550
kHz
Output ripple (VRIP)
(main)
700512T (aux.)
700515T (aux.)
Switching frequency (FS)
450
mV
mV
%
mA
For Notes to Electrical Performance Characteristics, refer to page 5
3
2016-06-30
M3G-SERIES
(70V Input, Triple Output)
Electrical Performance Characteristics (continued)
Parameter
Efficiency (EFF)
Group A
Subgroup
1,2,3
Inhibit input
open circuit voltage
drive current (sink)
voltage range
Power dissipation, load fault (PD)
Output response to
step load changes (VTLD)
Recovery time,
step load changes (TTLD)
Nom
78
82
-0.5
Ext. Clock on Sync. Input (Pin 4)
Note 1
450
4.0
-0.5
40
20
Unit
%
5.0
100
50
V
A
V
600
10.0
0.5
80
kHz
V
V
V/s
%
VOUT = 90% of Nominal, Note 5
135
%
1,2,3
Short Circuit, Overload, Note 8
18
W
4,5,6
Half Load to/from Full Load, Notes 5,9
300
mVpk
4,5,6
Half Load to/from Full Load, Note 5,9,10
200
s
300
mVpk
200
s
500
750
5.0
mV
mV
ms
1000
200
µF
Recovery time,
step line changes (TTLN)
Turn-on response
Overshoot (VOS)
60V to/from 100V
IOUT = 100% rated load, Notes 1. 5,10,11
4,5,6
-300
50
-300
50
No Load, Full Load
Notes 5,12
1.0
Capacitive load (CL)
IOUT = 100% rated load, No effect on DC
performance, Notes 1, 5, 7
(main)
(Each aux. output)
Line rejection
1
DC to 50 kHz, Notes 1, 5
IOUT = 100% rated load
40
Input to Output or Any Pin to Case
except pin 10, test @ 500VDC
100
Device weight
MTBF
Max
1,2,3
60V to/from 100V
IOUT = 100% rated load, Notes1, 5,11
Isolation
Min
3.0
Output response to
step line changes (VTLN)
(main)
(aux.)
Turn-on delay (TDLY)
Limits
Note 1
Synchronization input
frequency range
pulse high level
pulse low level
pulse transition time
pulse duty cycle
Current limit point
Expressed as a percentage
of full rated output power
Conditions
-55°C TC +85°C
VIN = 70V DC ± 5%, CL = 0
unless otherwise specified
IOUT = 100% rated load
Note 5
60
dB
M
110
MIL-HDBK-217F2, SF, 35°C
5 x 106
g
Hrs
For Notes to Electrical Performance Characteristics, refer to page 5
4
2016-06-30
M3G-SERIES
(70V Input, Triple Output)
Notes: Electrical Performance Characteristics Table
1. Parameter is tested as part of design characterization or after design changes. Thereafter, parameter shall be guaranteed
to the limits specified..
2. Parameter verified during line and load regulation tests.
3. Although operation with no load is permissible, light loading on the main (+5 volt) output may cause the output voltage of the auxiliary
outputs (±12 volt or ±15 volt) to drop out of regulation. It is therefore recommended that at least 200 mA or 20 percent of the total out
put power, whichever Is greater, be taken from the main (+5 volt) output.
4. Although operation with no load is permissible, heavy loading on the main (+5 volt) output may cause the output voltage of the auxiliary
outputs (±12 volt or ±15 volt) to rise out of regulation. It is therefore recommended that at least 50 mA or 20 percent of the total output
power, whichever is greater, be taken from the auxiliary (±12 volt or ±15 volt) outputs.
5. Unless otherwise specified, “Rated” load is 20W on the main (+5 volt) output and 10 watts each on the auxiliary (±12 volt or ±15 volt)
outputs. Load currents of up to 5A and ±1A on the main and auxiliary outputs respectively are acceptable as long as the total output
power does not to exceed 40 watts.
6. Guaranteed for a D.C. to 20 MHz bandwidth. Tested using a 20 kHz to 10 MHz bandwidth.
7. Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of
the maximum limit may interfere with the proper operation of the converter’s overload protection, causing erratic behavior during turn-on.
8. Overload power dissipation is defined as the device power dissipation with the load set such that VOUT = 90% of nominal.
9. Load step transition time 10 s.
10. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of its steady state value.
11. Line step transition time 100 s.
12. Turn-on delay time from either a step application of input power or a logic low to a logic high transition on the inhibit pin(pin3 to
the point where VOUT = 90% of nominal.
13. Load Regulation relative to output voltage at 50% rated load.
14. Line Regulation relative to output voltage at 70Vdc input.
15. Although operation at temperatures between +85°C and +125°C is guaranteed, no parametric limits are specified.
Radiation Performance Characteristics
Test
Conditions
Min
Typ
Unit
Total Ionizing Dose (Gamma)
MIL-STD-883, Method 1019
Operating bias applied during exposure,
Full Rated Load, VIN = 70V
200
300
kRads (Si)
Dose Rate (Gamma Dot)
Temporary Saturation
Survival
MIL-STD-883, Method 1023
Operating bias applied during exposure,
Full Rated Load, VIN = 70V
1E8
4E10
1E11
MIL-STD-883, Method 1017
8E12
1E13
Neutron Fluence
Single Event Effects
SEU, SEL, SEGR, SEB
Heavy ions (LET)
Operating bias applied during exposure,
Full Rated Load, VIN = 70V
Test lab: Brookhaven National Laboratory,
Tandem Van de Graaff Generator
82
Rads (Si)/sec
Neutrons/cm2
MeVcm2 /mg
IR HiRel currently does not have a DLA Land and Maritime certified Radiation Hardness Assurance Program.
5
2016-06-30
M3G-SERIES
(70V Input, Triple Output)
Fig 1. Block Diagram - Triple Output
Vin
EMI
FILTER
1
+10.5V
UNDER VOLTAGE
LOCKOUT
& INHIBIT
INHIBIT 3
BIAS
SUPPLY
+AUX.
OUTPUT
12
AUX.
RETURN
11
-AUX.
OUTPUT
7
+MAIN
6
MAIN
RETURN
10
CASE
GROUND
+5V
SHORT CIRCUIT
&
OVERLOAD
LEVEL
TRANSLATOR
& FET DRIVE
RETURN
13
2
+5V
+
+5V
EA
-
SYNC.
INPUT
4
+
OSCILLATOR
SYNC.
OUTPUT
PWM
5
-
RAMP
GENERATOR
REF
SAMPLE
&
HOLD
FEEDBACK
TRIGGER
Fig 2. ±12V Load Regulation vs 5V Load
14
±12V Magnitudes ( Volts )
13.5
13
12.5
12
5V load = 4A
5V load = 2A
11.5
5V load = 0.4A
11
10.5
10
0
6
0.1
0.2
0.3
0.4
0.5
0.6
±12V Load Current ( Amps each )
0.7
0.8
0.9
1
2016-06-30
M3G-SERIES
(70V Input, Triple Output)
Fig 3. ±15V Load Regulation vs 5V Load
18
17.5
±15V Magnitudes ( Volts )
17
16.5
16
15.5
15
5V load = 4A
14.5
5V load = 2A
14
5V load = 0.4A
13.5
13
0
0.1
0.2
0.3
0.4
0.5
0.6
±15V Load Current ( Amps each )
0.7
0.8
0.9
1
Fig 4. Line Rejection, Main Output
0
-10
-20
-30
dB
-40
-50
-60
-70
-80
-90
-100
1E2
1E3
1E4
1E5
Frequency ( Hz )
7
2016-06-30
M3G-SERIES
(70V Input, Triple Output)
Fig 5. Line Rejection, Aux. Outputs
0
-10
-20
-30
dB
-40
-50
-60
-70
-80
-90
-100
1E2
1E3
1E4
1E5
Frequency ( Hz )
Fig 6. Conducted Emissions, Normal Mode
100
90
80
70
MIL-STD-461C
CE03 LIMIT
dB-uA
60
50
40
30
20
10
0
1E3
1E4
1E5
1E6
1E7
1E8
Frequency ( Hz )
8
2016-06-30
M3G-SERIES
(70V Input, Triple Output)
Fig 7. Conducted Emissions, Common Mode
100
90
80
70
MIL-STD-461C
CE03 LIMIT
dB-uA
60
50
40
30
20
10
0
1E3
1E4
1E5
1E6
1E7
1E8
Frequency ( Hz )
Application Notes
A) Attachment of the Converter:
The following procedure is recommended for mounting the converter for optimum cooling and to circumvent any potential
damage to the converter.
Ensure that flatness of the plate where M3G converter to be mounted is no greater than 0.003” per linear inch. It is
recommended that a thermally conductive gasket is used to promote the thermal transfer and to fill any voids existing
between the two surfaces. IR HiRel recommends Sil-Pad 2000 with the thickness of 0.010". The shape of the gasket
should match the footprint of the converter including the mounting flanges. The gasket is available from IR HiRel. The
M3G-Series converter requires either M3 or 4-40 size screws for attachment purposes.
The procedure for mounting the converter is as follows
1. Check the mounting surfaces and remove foreign material, burrs if any or anything that may
interfere with the attachment of the converter.
2. Place the gasket on the surface reserved for the converter and line it up with the mounting holes.
3. Place the converter on the gasket and line both up with mounting holes.
4. Install screws using appropriate washers and tighten by hand (~ 4 in·oz) in the sequence shown below.
5. Tighten the screws with an appropriate torque driver. Torque the screws up to 6 in·lb in the sequence shown above.
9
2016-06-30
M3G-SERIES
(70V Input, Triple Output)
Mechanical Outline
3.055 MAX.
0.500
0.080
Max.
2.00
R0.0625
4 places
0.30
0.50
0.20
13
1
12
2
11
10
0.60
9
3
8
4
7
5
6
2.055
MAX.
2.30
2.500
0.200 Typ.
Noncum.
1.400
Ref.
Pin
Ø0.040
0.45
1.10
0.260
FLANGE DETAIL
3.50
Ref.
5
62
.0
R0
0.25
0.25
0.14
0.475
MAX.
0.40
Tolerance :
.XX
.XXX
±0.01
±0.005
Pin Designation
10
Pin #
Designation
Pin #
Designation
1
+ Input
8
NC
2
Input Return
9
NC
3
Inhibit
10
Case Ground
4
Sync. Input
11
- Aux. Output
5
Sync. Output
12
Aux. Output Return
6
Main Return
13
+ Aux. Output
7
+ Main Output
2016-06-30
M3G-SERIES
(70V Input, Triple Output)
Device Screening
Requirement
MIL-STD-883 Method
No Suffix 
CK 
EM 
Temperature Range
—
-55°C to +85°C
-55°C to +85°C
-55°C to +85°C
Element Evaluation
MIL-PRF-38534
Class K
Class K
N/A
Non-Destructive Bond Pull
2023
Yes
Yes
N/A
Internal Visual
2017
Yes
Yes

Temperature Cycle
1010
Cond C
Cond C
Cond C
Constant Acceleration
PIND
2001, Y1 Axis
2020
1015
Final Electrical
(Group A)
PDA
MIL-PRF-38534
& Specification
MIL-PRF-38534
3000 Gs
Cond A
320 hrs @ 125°C
(2 x 160 hrs)
-55°C, +25°C,
+85°C
2%
3000 Gs
N/A
Burn-In
3000 Gs
Cond A
320 hrs @ 125°C
(2 x 160 hrs)
-55°C, +25°C,
+85°C
2%
Seal, Fine and Gross
1014
Cond A, C
Cond A, C
Cond A
Radiographic
2012
Yes
Yes
N/A
External Visual
2009
Yes
Yes

48 hrs @ 125°C
-55°C, +25°C,
+85°C
N/A
Notes:
 Best commercial practice.
 CK is a DLA Land and Maritime (formerly DSCC) part marking used to designate a Class K compliant hybrid.
The CK marking does not indicate the hybrid is radiation certified.
No Suffix is a radiation rated device but not available as a DLA Land and Maritime qualified SMD per MIL-PRF-38534.
 Any Engineering Model (EM) build with the “EM” Suffix shall only be form, fit and functional equivalent to its
Flight Model (FM) counterpart, and it may not meet the radiation performance. The EM Model shall not be expected
comply with MIL-PRF-38534 flight quality/workmanship standards, and configuration control. An EM build may use
electrical equivalent commercial grade components. IR HiRel will provide a list of non-compliance items upon request.
Part Numbering
M3G 70 05 15 T /XX X
Model
Nominal Input
Voltage
70 = 70V
Main Output
Voltage
03R3 = 3.3V
05 = 5V
12 = 12V
15 =15V
Lead Finish for CK only
C = Gold Plated
A = Solder Dipped
Blank for No Suffix and EM
Lead Finish for No Suffix = Gold Plated
Lead Finish for EM is Gold Plated or
Solder Dipped depending on availability
Screening Level
(Please refer to Screening Table)
No Suffix, CK, EM
Output
T = Triple
Auxiliary Output Voltage
05 =  5V, 12 =  12V, 15 =  15V
IR HiRel Headquarters: 101 N. Sepulveda Blvd., El Segundo, California 90245, USA Tel: (310) 252-7105
IR HiRel Leominster: 205 Crawford St., Leominster, Massachusetts 01453, USA Tel: (978) 534-5776
IR HiRel San Jose: 2520 Junction Avenue, San Jose, California 95134, USA Tel: (408) 434-5000
Data and specifications subject to change without notice.
11
2016-06-30
M3G-SERIES
(70V Input, Triple Output)
IMPORTANT NOTICE
The information given in this document shall be in no event regarded as guarantee of conditions or characteristic. The
data contained herein is a characterization of the component based on internal standards and is intended to
demonstrate and provide guidance for typical part performance. It will require further evaluation, qualification and
analysis to determine suitability in the application environment to confirm compliance to your system requirements.
With respect to any example hints or any typical values stated herein and/or any information regarding the application of
the product, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind including without
limitation warranties on non- infringement of intellectual property rights and any third party.
In addition, any information given in this document is subject to customer’s compliance with its obligations stated in this
document and any applicable legal requirements, norms and standards concerning customer’s product and any use of
the product of Infineon Technologies in customer’s applications.
The data contained in this document is exclusively intended for technically trained staff. It is the responsibility of any
customer’s technical departments to evaluate the suitability of the product for the intended applications and the
completeness of the product information given in this document with respect to applications.
For further information on the product, technology, delivery terms and conditions and prices, please contact your local
sales representative or go to (www.infineon.com/hirel).
WARNING
Due to technical requirements products may contain dangerous substances. For information on the types in question,
please contact your nearest Infineon Technologies office.
12
2016-06-30