Vicor BCM48BT030M210A00 Isolated fixed ratio dc-dc converter Datasheet

BCM® Bus Converter
BCM48Bx030y210A00
S
®
US
C
C
NRTL
US
Isolated Fixed Ratio DC-DC Converter
Features & Benefits
Product Ratings
• 48VDC – 3VDC 210W Bus Converter
• High efficiency (>94%) reduces system
power consumption
• High power density (>715W/in3) reduces
power system footprint by >40%
VIN = 48V (38 – 55V)
POUT = up to 210W
VOUT = 3V (2.4 – 3.4V)
(no load)
K = 1/16
Description
The VI Chip® bus converter is a high efficiency (>94%) Sine
Amplitude Converter™ (SAC™) operating from a 38 to 55VDC
primary bus to deliver an isolated, ratiometric output voltage from
2.4 to 3.4VDC. The Sine Amplitude Converter offers a low AC
impedance beyond the bandwidth of most downstream regulators;
therefore capacitance normally at the load can be located at the
input to the Sine Amplitude Converter. Since the transformation
ratio of the BCM48Bx030y210A00 is 1/16, the capacitance value
can be reduced by a factor of 256x, resulting in savings of board
area, materials and total system cost.
• Contains built-in protection features:
n Undervoltage
n Overvoltage Lockout
n Overcurrent Protection
n Short circuit Protection
n Overtemperature Protection
• Provides enable/disable control, internal
temperature monitoring
• Can be paralleled to create multi-kW arrays
The BCM48BF030y210A00 is provided in a VI Chip package
compatible with standard pick-and-place and surface mount
assembly processes. The co-molded VI Chip package provides
enhanced thermal management due to a large thermal interface
area and superior thermal conductivity. The high conversion
efficiency of the BCM48Bx030y210A00 increases overall
system efficiency and lowers operating costs compared to
conventional approaches.
Typical Applications
• High End Computing Systems
• Automated Test Equipment
• High Density Power Supplies
Part Numbering
• Communications Systems
Product Number
BCM48Bx030y210A00
Package Style (x)
Product Grade (y)
F = J-Lead
T = -40° to 125°C
T = Through hole
M = -55° to 125°C
For Storage and Operating Temperatures see General Characteristics
Typical Application
enable / disable
switch
SW1
F1
PC
TM
L
O
A
D
BCM®
Bus Converter
+IN
+OUT
-IN
-OUT
VIN
BCM® Bus Converter
Page 1 of 20
Rev 1.5
08/2016
vicorpower.com
800 927.9474
BCM48Bx030y210A00
Pin Configuration
4
3
2
1
A
A
+OUT
B
B
C
C
D
D
E
E
-OUT
F
G
H
H
J
J
+OUT
-OUT
+IN
K
K
L
L
M
M
N
N
P
P
R
R
TM
RSV
PC
-IN
T
T
Bottom View
Pin Descriptions
Pin Number
Signal Name
Type
Function
A1-E1, A2-E2
+IN
INPUT POWER
Positive input power terminal
L1-T1, L2-T2
–IN
INPUT POWER
RETURN
Negative input power terminal
H1, H2
TM
OUTPUT
J1, J2
RSV
NC
Temperature monitor, input side referenced signal
No connect
K1, K2
PC
OUTPUT/INPUT
A3-D3, A4-D4,
J3-M3, J4-M4
+OUT
OUTPUT POWER
Positive output power terminal
E3-H3, E4-H4,
N3-T3, N4-T4
–OUT
OUTPUT POWER
RETURN
Negative output power terminal
BCM® Bus Converter
Page 2 of 20
Rev 1.5
08/2016
Enable and disable control, input side referenced signal
vicorpower.com
800 927.9474
BCM48Bx030y210A00
Absolute Maximum Ratings
The absolute maximum ratings below are stress ratings only. Operation at or beyond these maximum ratings can cause permanent damage to the device.
Parameter
Comments
+IN to –IN
VIN slew rate
Operational
Min
Max
-1
60
V
-1
1
V/µs
2250
V
-1
6
V
-3
105
A
Isolation voltage, input to ouput
+OUT to –OUT
Output current transient
≤ 10ms, ≤ 10% DC
Output current average
Unit
-2
80
A
PC to –IN
-0.3
20
V
TM to –IN
-0.3
7
V
BCM® Bus Converter
Page 3 of 20
Rev 1.5
08/2016
vicorpower.com
800 927.9474
BCM48Bx030y210A00
Electrical Specifications
Specifications apply over all line and load conditions unless otherwise noted; boldface specifications apply over the temperature range of
​-40​°C ≤ TCASE ≤ ​100​°C (T-Grade); all other specifications are at TCASE = ​25​ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
38
55
V
38
55
V
Powertrain
Input voltage range, continuous
Input voltage range, transient
VIN_DC
VIN_TRANS
Quiescent current
IQ
VIN to VOUT time
TON1
Full current or power supported, 50ms max,
10% duty cycle max
Disabled, PC Low
VIN = 48V, PC floating
450
VIN = 48V, TCASE = 25ºC
No load power dissipation
PNL
At POUT = 210W
POUT_PK
Output current (average)
IOUT_AVG
Output current (peak)
IOUT_PK
Efficiency (ambient)
hAMB
5.5
8.5
10.5
IIN_DC
Output power (peak)
4.6
VIN = 38V to 55V
DC input current
POUT_AVG
ms
6.5
Worse case of: VIN = 55V, COUT = 16000μF,
RLOAD = 36mΩ
Output power (average)
mA
VIN = 38V to 55V, TCASE = 25ºC
IINR_P
K
1.0
800
1.5
VIN = 48V
Inrush current peak
Transformation ratio
0.5
650
10
K = VOUT / VIN, at no load
W
20
A
5
A
1/16
V/V
210
W
10ms max, POUT_AVG ≤ 210W
315
W
80
A
10ms max, IOUT_AVG ≤ 80A
105
A
VIN = 48V, IOUT = 70A; TCASE = 25°C
92.8
94.3
VIN = 38V to 55V, IOUT = 70A; TC = 25°C
88.8
VIN = 48V, IOUT = 35A; TCASE = 25°C
92.7
94.2
92.8
94.3
%
Efficiency (hot)
hHOT
VIN = 48V, IOUT = 70A; TCASE = 100°C
Efficiency (over load range)
h20%
14A < IOUT < 40A
80
ROUT_COLD
IOUT = 70A, TCASE = -40°C
0.6
1.0
1.8
ROUT_AMB
IOUT = 70A, TCASE = 25°C
0.8
1.4
2.2
ROUT_HOT
IOUT = 70A, TCASE = 100°C
1.0
1.6
2.4
1.36
1.43
1.50
MHz
330
mV
Output resistance
%
%
mΩ
Switching frequency
FSW
Output voltage ripple
VOUT_PP
COUT = 0F, IOUT = 70A, VIN = 48V,
20MHz BW
225
Output inductance (parasitic)
LOUT_PAR
Frequency up to 30MHz, Simulated J-lead model
600
pH
Output capacitance (internal)
COUT_INT
Effective value at 3VOUT
200
µF
Output capacitance (external)
COUT_EXT
BCM® Bus Converter
Page 4 of 20
0
Rev 1.5
08/2016
vicorpower.com
800 927.9474
16000
µF
BCM48Bx030y210A00
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TCASE ≤ 100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Protection
Input overvoltage lockout threshold
VIN_OVLO+
55.1
58.5
60
V
Input overvoltage recovery threshold
VIN_OVLO-
55.1
58.0
60
V
Input overvoltage lockout hysteresis
VIN_OVLO_HYST
1.2
V
Overvoltage lockout response time
TOVLO
8
µs
TAUTO_RESTART
350
420
530
ms
Input undervoltage lockout
threshold
VIN_UVLO-
28.5
31.1
37.4
V
Input undervoltage recovery
threshold
VIN_UVLO+
28.5
33.7
37.4
V
Input undervoltage lockout
hysteresis
VIN_UVLO_HYST
1.6
V
TUVLO
8
µs
Undervoltage lockout response time
Output overcurrent trip threshold
IOCP
Output overcurrent response time
constant
TOCP
Short circuit protection trip threshold
ISCP
Short circuit protection response time
TSCP
Output Power (W)
Thermal shutdown threshold
82
Effective internal RC filter
107
140
4.9
ms
140
A
1
µs
125
TJ_OTP
°C
400
160
350
140
300
120
250
100
200
80
150
60
100
40
20
50
2.13
2.26
2.40
2.53
2.66
2.79
2.93
3.06
3.19
Output Voltage (V)
P (ave)
P (pk), < 10ms
I (ave)
Figure 1 — Safe operating area
BCM® Bus Converter
Page 5 of 20
A
Rev 1.5
08/2016
vicorpower.com
800 927.9474
I (pk), < 10ms
3.33
3.46
Output Current (A)
Fault recovery time
BCM48Bx030y210A00
Signal Characteristics
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TCASE ≤ 100°C (T-Grade; all other specifications are at TCASE = 25ºC unless otherwise noted.
Primary Control: PC
• The PC pin enables and disables the BCM. When held low, the BCM is disabled.
• In an array of BCM modules, PC pins should be interconnected to synchronize start up and permit start up into full load conditions.
• PC pin outputs 5V during normal operation. PC pin internal bias level drops to 2.5V during fault mode, provided VIN remains
in the valid range.
SIGNAL TYPE
STATE
Regular
Operation
ANALOG
OUTPUT
Standby
Transition
Start Up
DIGITAL
INPUT /
OUTPUT
ATTRIBUTE
SYMBOL
MIN
TYP
MAX
UNIT
VPC
4.7
5.0
5.3
V
PC available current
IPC_OP
2.0
3.5
5.0
mA
PC source (current)
IPC_EN
50
100
PC resistance (internal)
RPC_INT
50
150
PC capacitance (internal)
CPC_INT
PC voltage
PC load resistance
RPC_S
Regular
Operation
PC enable threshold
VPC_EN
PC disable threshold
VPC_DIS
Standby
PC disable duration
TPC_DIS_T
Transition
CONDITIONS / NOTES
PC threshold hysteresis
VPC_HYSTER
PC enable to VOUT time
TON2
PC disable to standby time
TPC_DIS
PC fault response time
TFR_PC
Internal pull down resistor
To permit regular operation
µA
400
kΩ
1000
pF
60
2.0
Minimum time before attempting
re-enable
1
VIN = 48V for at least TON1 ms
50
kΩ
2.5
3.0
V
1.95
V
s
50
From fault to PC = 2V
mV
100
150
µs
4
10
µs
100
µs
Temperature Monitor: TM
• The TM pin monitors the internal temperature of the controller IC within an accuracy of ±5°C.
• Can be used as a “Power Good” flag to verify that the BCM module is operating.
• Is used to drive the internal comparator for Overtemperature Shutdown.
SIGNAL TYPE
STATE
ATTRIBUTE
TM voltage range
ANALOG
OUTPUT
Regular
Operation
DIGITAL
INPUT /
OUTPUT
Standby
CONDITIONS / NOTES
VTM_AMB
TM available current
ITM
TJ controller = 27°C
2.95
ATM
TM voltage ripple
VTM_PP
TM capacitance (external)
CTM_EXT
TM fault response time
TFR_TM
TM voltage
VTM_DIS
TM pull down (internal)
RTM_INT
3.00
120
From fault to TM = 1.5V
Internal pull down resistor
Reserved for factory use. No connection should be made to this pin.
Rev 1.5
08/2016
TYP
MAX
UNIT
4.04
V
3.05
V
100
µA
10
CTM = 0pF, VIN = 48V, IOUT = 70A
Reserved: RSV
BCM® Bus Converter
Page 6 of 20
MIN
2.12
VTM
TM voltage reference
TM gain
Transition
SYMBOL
vicorpower.com
800 927.9474
25
mV/°C
200
mV
50
pF
10
µs
0
V
40
50
kΩ
BCM® Bus Converter
Page 7 of 20
NL
5V
2.5 V
5V
3V
PC
VUVLO+
VUVLO–
Rev 1.5
08/2016
vicorpower.com
800 927.9474
1
A
E: TON2
F: TOCP
G: TPC–DIS
H: TSCP**
B
D
1: Controller start
2: Controller turn off
3: PC release
C
*Min value switching off
**From detection of error to power train shut down
A: TON1
B: TOVLO*
C: TAUTO_RESTART
D:TUVLO
0.4 V
3 V @ 27°C
TM
LL • K
VOUT
C
500mS
before retrial
3V
VIN
VOVLO+
VOVLO–
2
F
4: PC pulled low
5: PC released on output SC
6: SC removed
IOCP
ISSP
IOUT
E
3
G
4
Notes:
H
5
– Timing and signal amplitudes are not to scale
– Error pulse width is load dependent
6
BCM48Bx030y210A00
Timing Diagram
BCM48Bx030y210A00
Application Characteristics
10
95
9
Full Load Efficiency (%)
No Load Power Dissipation (W)
The following values, typical of an application environment, are collected at TCASE = 25ºC unless otherwise noted. See associated figures for general trend data.
8
7
6
5
4
3
2
1
0
38
40
42
44
46
47
49
51
53
95
94
94
93
93
92
55
Input Voltage (V)
TCASE:
-40°C
25°C
-20
0
40
60
80
38V
48V
100
55V
Figure 3 — Full load efficiency vs. temperature; Vin
35
94
30
Power Dissipation (W)
98
90
86
82
78
74
25
20
15
10
5
0
70
0
5
0
10 15 20 25 30 35 40 45 50 55 60 65 70
5
10 15 20 25 30 35 40 45 50 55 60 65 70
Load Current (A)
VIN:
38V
48V
Load Current (A)
55V
Figure 4 — Efficiency at TCASE = -40°C
VIN:
38V
48V
55V
Figure 5 — Power dissipation at TCASE = -40°C
98
35
94
30
Power Dissipation (W)
Efficiency (%)
20
Case Temperature (°C)
VIN :
100°C
Figure 2 — No load power dissipation vs. Vin
Efficiency (%)
-40
90
86
82
78
74
25
20
15
10
5
0
70
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70
Load Current (A)
Load Current (A)
VIN:
38V
48V
Figure 6 — Efficiency at TCASE = 25°C
BCM® Bus Converter
Page 8 of 20
VIN:
55V
38V
48V
Figure 7 — Power dissipation at TCASE = 25°C
Rev 1.5
08/2016
vicorpower.com
800 927.9474
55V
BCM48Bx030y210A00
98
35
94
30
Power Dissipation (W)
Efficiency (%)
Application Characteristics (Cont.)
90
86
82
78
74
70
25
20
15
10
5
0
0
5
0
10 15 20 25 30 35 40 45 50 55 60 65 70
5
10 15 20 25 30 35 40 45 50 55 60 65 70
Load Current (A)
38V
VIN:
Load Current (A)
48V
55V
Figure 8 — Efficiency at TCASE = 100°C
48V
55V
Figure 9 — Power dissipation at TCASE = 100°C
250
2.0
225
Ripple (mV pk-pk)
1.8
ROUT (mΩ)
38V
VIN:
1.5
1.3
1.0
0.8
200
175
150
125
100
75
50
25
0
0.5
-40
-20
0
20
40
60
80
100
0
5
10 15 20
I OUT :
35A
BCM® Bus Converter
Page 9 of 20
VIN :
70A
Figure 10 — ROUT vs. temperature; nominal input
Rev 1.5
08/2016
25 30
35 40 45
50 55 60
65 70
Load Current (A)
Case Temperature (°C)
48 V
Figure 11 — Vripple vs. Iout: no external Cout, board mounted
module, scope setting : 20MHz analog BW
vicorpower.com
800 927.9474
BCM48Bx030y210A00
Application Characteristics (Cont.)
Figure 12 — Full load ripple, 330µF Cin: no external Cout, board
mounted module, scope setting : 20MHz analog BW
Figure 13 — Start up from application of PC;
Vin pre-applied Cout = 16000µF
Figure 14 — 0A – 70A transient response: Cin = 330µF, Iin measured
prior to Cin, no external Cout
Figure 15 — 70A – 0A transient response: Cin = 330µF, Iin measured
prior to Cin, no external Cout
BCM® Bus Converter
Page 10 of 20
Rev 1.5
08/2016
vicorpower.com
800 927.9474
BCM48Bx030y210A00
General Characteristics
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TCASE ≤ 100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Mechanical
Length
L
32.25 / [1.270] 32.50 / [1.280] 32.75 / [1.289] mm / [in]
Width
W
21.75 / [0.856] 22.00 / [0.866] 22.25 / [0.876] mm / [in]
Height
H
Volume
Vol
Weight
W
6.48 / [0.255]
No heat sink
Lead Finish
6.73 / [0.265] 6.98 / [0.275]
mm / [in]
4.81 / [0.294]
cm3/ [in3]
14.5 / [0.512]
g / [oz]
Nickel
0.51
2.03
Palladium
0.02
0.15
Gold
0.003
0.051
BCM48Bx030T210A00 (T-Grade)
-40
125
BCM48Bx030M210A00 (M-Grade)
-55
125
µm
Thermal
Operating temperature
TJ
Thermal resistance
fJC
Isothermal heatsink and
isothermal internal PCB
Thermal capacity
°C
1
°C/W
5
Ws/°C
Assembly
Peak compressive force
applied to case (Z-axis)
Storage
Temperature
Supported by J-lead only
TST
lbs
lbs/ in2
BCM48Bx030T210A00 (T-Grade)
-40
125
°C
BCM48Bx030M210A00 (M-Grade)
-65
125
°C
ESDHBM
Human Body Model,
“JEDEC JESD 22-A114D.01”Class 1D
1000
ESDCDM
Charge Device Model,
“JEDEC JESD 22-C101-D”
400
ESD Withstand
6
5.41
V
Soldering
Peak temperature during reflow
MSL 4 (Datecode 1528 and later)
245
°C
Peak time above 217°C
60
90
s
Peak heating rate during reflow
1.5
3
°C/s
Peak cooling rate post reflow
1.5
6
°C/s
60
VDC
Safety
Working voltage (IN – OUT)
VIN_OUT
Isolation voltage (hipot)
VHIPOT
Isolation capacitance
CIN_OUT
Unpowered unit
Isolation resistance
RIN_OUT
At 500VDC
MTBF
2,250
2500
VDC
3200
10
MIL-HDBK-217Plus Parts Count - 25°C
Ground Benign, Stationary, Indoors /
Computer Profile
5.04
MHrs
Telcordia Issue 2 - Method I Case III;
25°C Ground Benign, Controlled
6.35
MHrs
cURus
CE Marked for Low Voltage Directive and ROHS recast directive, as applicable.
BCM® Bus Converter
Page 11 of 20
pF
MΩ
cTUVus
Agency approvals / standards
3800
Rev 1.5
08/2016
vicorpower.com
800 927.9474
BCM48Bx030y210A00
­Using the Control Signals PC, TM
Primary Control (PC) pin can be used to accomplish the
following functions:
n Logic enable and disable for module: Once TON1 time has
been satisfied, a PC voltage greater than VPC_EN will cause
the module to start. Bringing PC lower than VPC_DIS will
cause the module to enter standby.
n Auxiliary voltage source: Once enabled in regular
operational conditions (no fault), each BCM module
PC provides a regulated 5V, 3.5mA voltage source.
n Synchronized start up: In an array of parallel modules, PC
pins should be connected to synchronize start up across
units. This permits the maximum load and capacitance
to scale by the number of paralleled modules.
n Output disable: PC pin can be actively pulled down in order
to disable the module. Pull down impedance shall be lower
than 60Ω.
n Fault detection flag: The PC 5V voltage source is internally
turned off as soon as a fault is detected.
n Note that PC can not sink significant current during a fault
condition. The PC pin of a faulted module will not cause
interconnected PC pins of other modules to be disabled.
Temperature Monitor (TM) pin provides a voltage proportional
to the absolute temperature of the converter control IC.
It can be used to accomplish the following functions:
n Monitor the control IC temperature: The temperature in
Kelvin is equal to the voltage on the TM pin scaled
by 100. (i.e. 3.0V = 300K = 27ºC). If a heat sink is applied,
TM can be used to protect the system thermally.
n Fault detection flag: The TM voltage source is internally
turned off as soon as a fault is detected. For system
monitoring purposes microcontroller interface faults are
detected on falling edges of TM signal.
BCM® Bus Converter
Page 12 of 20
Rev 1.5
08/2016
vicorpower.com
800 927.9474
BCM48Bx030y210A00
Sine Amplitude Converter™ Point of Load Conversion
218pH
+
RRC
cin
IN
CCINin
3.2µF
ROUT
1.4mΩ
1/16 • Iout
IIQQ
81mA
+
+
–
–
K
Lout = 600pH
+
RRcC
OUT
out
81µΩ
0.2Ω
V•I
0.57mΩ
VinIN
V
Rout
out
IIOUT
Lin = 5.7nH
1/16 • Vin
CC
out
OUT
VVout
OUT
200µF
–
–
Figure 16 — VI Chip® module AC model
The Sine Amplitude Converter (SAC™) uses a high frequency
resonant tank to move energy from input to output. The resonant
LC tank, operated at high frequency, is amplitude modulated as
a function of input voltage and output current. A small amount
of capacitance embedded in the input and output stages of the
module is sufficient for full functionality and is key to achieving
power density.
The BCM48Bx030y210A00 SAC can be simplified into the
preceeding model.
ROUT represents the impedance of the SAC, and is a function of the
Rdson of the input and output MOSFETs and the winding resistance
of the power transformer. Iq represents the quiescent current of
the SAC control, gate drive circuitry, and core losses.
The use of DC voltage transformation provides additional
interesting attributes. Assuming that ROUT = 0Ω and IQ = 0A, Eq. (3)
now becomes Eq. (1) and is essentially load independent, resistor R
is now placed in series with VIN.
At no load:
R
VOUT = VIN • K
(1)
VVin
in
+
–
SAC™
SAC
K=
= 1/32
1/16
K
Vout
V
out
K represents the “turns ratio” of the SAC.
Rearranging Eq (1):
VOUT
K=
VIN
(2)
Figure 17 — K = 1/16 Sine Amplitude Converter
with series input resistor
The relationship between VIN and VOUT becomes:
In the presence of load, VOUT is represented by:
VOUT = (VIN – IIN • R) • K
VOUT = VIN • K – IOUT • ROUT
(3)
and Iout is represented by:
IIN – IQ
IOUT =
K
BCM® Bus Converter
Page 13 of 20
(4)
Rev 1.5
08/2016
(5)
Substituting the simplified version of Eq. (4)
(IQ is assumed = 0A) into Eq. (5) yields:
VOUT = VIN • K – IOUT • R • K2
vicorpower.com
800 927.9474
(6)
BCM48Bx030y210A00
This is similar in form to Eq. (3), where ROUT is used to represent
the characteristic impedance of the SAC™. However, in this case a
real R on the input side of the SAC is effectively scaled by K 2 with
respect to the output.
Assuming that R = 1Ω, the effective R as seen from the secondary
side is 3.9mΩ, with K = 1/16.
A similar exercise should be performed with the additon of a
capacitor or shunt impedance at the input to the SAC.
A switch in series with VIN is added to the circuit. This is depicted in
Figure 18.
A solution for keeping the impedance of the SAC low involves
switching at a high frequency. This enables small magnetic
components because magnetizing currents remain low. Small
magnetics mean small path lengths for turns. Use of low loss core
material at high frequencies also reduces core losses.
S
VVin
in
+
–
Low impedance is a key requirement for powering a highcurrent, low-voltage load efficiently. A switching regulation stage
should have minimal impedance while simultaneously providing
appropriate filtering for any switched current. The use of a SAC
between the regulation stage and the point of load provides a
dual benefit of scaling down series impedance leading back to
the source and scaling up shunt capacitance or energy storage
as a function of its K factor squared. However, the benefits are
not useful if the series impedance of the SAC is too high. The
impedance of the SAC must be low, i.e. well beyond the crossover
frequency of the system.
C
C
SAC™
SAC
K = 1/16
K = 1/32
VVout
out
The two main terms of power loss in the BCM module are:
n No load power dissipation (PNL): defined as the power
used to power up the module with an enabled powertrain
at no load.
Figure 18 — Sine Amplitude Converter™ with input capacitor
A change in VIN with the switch closed would result in a change in
capacitor current according to the following equation:
n Resistive loss (PR
): refers to the power loss across OUT
the BCM module modeled as pure resistive impedance.
PDISSIPATED = PNL + PROUT
(10)
Therefore,
IC(t) = C
dVIN
(7)
dt
POUT = PIN – PDISSIPATED = PIN – PNL – PROUT
Assume that with the capacitor charged to VIN, the switch is
opened and the capacitor is discharged through the idealized SAC.
In this case,
IC = IOUT • K
(8)
substituting Eq. (1) and (8) into Eq. (7) reveals:
The above relations can be combined to calculate the overall
module efficiency:
POUT
PIN – PNL – PROUT
h =
=
P P
IN
IN
= VIN • IIN – PNL – (IOUT)2 • ROUT
VIN • IIN
IOUT = C • dVOUT
K2 dt
(9)
= 1–
(PNL + (IOUT)2 • ROUT)
VIN • IIN
K2
The equation in terms of the output has yielded a
scaling factor
for C, specified in the denominator of the equation.
A K factor less than unity results in an effectively larger capacitance
on the output when expressed in terms of the input. With a
K = 1/16 as shown in Figure 18, C = 1µF would appear as
C = 256µF when viewed from the output.
BCM® Bus Converter
Page 14 of 20
Rev 1.5
08/2016
(11)
vicorpower.com
800 927.9474
(12)
BCM48Bx030y210A00
Input and Output Filter Design
A major advantage of SAC™ systems versus conventional PWM
converters is that the transformers do not require large
functional filters. The resonant LC tank, operated at extreme high
frequency, is amplitude modulated as a function of input voltage
and output current and efficiently transfers charge through the
isolation transformer. A small amount of capacitance embedded
in the input and output stages of the module is sufficient for full
functionality and is key to achieve power density.
This paradigm shift requires system design to carefully evaluate
external filters in order to:
1. Guarantee low source impedance:
To take full advantage of the BCM module’s dynamic
response, the impedance presented to its input terminals
must be low from DC to approximately 5MHz. The
connection of the bus converter module to its power
source should be implemented with minimal distribution
inductance. If the interconnect inductance exceeds
100nH, the input should be bypassed with a RC damper
to retain low source impedance and stable operation.
With an interconnect inductance of 200nH, the RC damper
may be as high as 1µF in series with 0.3Ω. A single
electrolytic or equivalent low-Q capacitor may be used in
place of the series RC bypass.
2. Further reduce input and/or output voltage ripple without sacrificing dynamic response:
Given the wide bandwidth of the module, the source
response is generally the limiting factor in the overall
system response. Anomalies in the response of the source
will appear at the output of the module multiplied by its
K factor. This is illustrated in Figures 14 and 15.
Within this frequency range, capacitance at the input appears as
effective capacitance on the output per the relationship
defined in Eq. 13.
COUT = CIN
K2
This enables a reduction in the size and number of capacitors used
in a typical system.
Thermal Considerations
VI Chip® products are multi-chip modules whose temperature
distribution varies greatly for each part number as well as with the
input / output conditions, thermal management and environmental
conditions. Maintaining the top of the BCM48Bx030y210A00 case
to less than 100ºC will keep all junctions within the VI Chip module
below 125ºC for most applications.
The percent of total heat dissipated through the top surface
versus through the J-lead is entirely dependent on the particular
mechanical and thermal environment. The heat dissipated through
the top surface is typically 60%. The heat dissipated through the
J-lead onto the PCB surface is typically 40%. Use 100% top surface
dissipation when designing for a conservative cooling solution.
It is not recommended to use a VI Chip module for an extended
period of time at full load without proper heat sinking.
3. Protect the module from overvoltage transients imposed
by the system that would exceed maximum ratings and
cause failures:
The module input/output voltage ranges shall not be
exceeded. An internal overvoltage lockout function
prevents operation outside of the normal operating input
range. Even during this condition, the powertrain is
exposed to the applied voltage and power MOSFETs must
withstand it. A criterion for protection is the maximum
amount of energy that the input or output switches can
tolerate if avalanched.
Total load capacitance at the output of the BCM module shall not
exceed the specified maximum. Owing to the wide bandwidth
and low output impedance of the module, low-frequency bypass
capacitance and significant energy storage may be more densely
and efficiently provided by adding capacitance at the input of
the module. At frequencies <500kHz the module appears as an
impedance of ROUT between the source and load.
BCM® Bus Converter
Page 15 of 20
Rev 1.5
08/2016
(13)
vicorpower.com
800 927.9474
BCM48Bx030y210A00
Current Sharing
Fuse Selection
The performance of the SAC™ topology is based on efficient
transfer of energy through a transformer without the need of
closed loop control. For this reason, the transfer characteristic
can be approximated by an ideal transformer with a positive
temperature coefficient series resistance.
In order to provide flexibility in configuring power systems
VI Chip® modules are not internally fused. Input line fusing
of VI Chip products is recommended at system level to provide
thermal protection in case of catastrophic failure.
This type of characteristic is close to the impedance characteristic
of a DC power distribution system both in dynamic (AC) behavior
and for steady state (DC) operation.
When multiple BCM modules of a given part number are
connected in an array they will inherently share the load current
according to the equivalent impedance divider that the system
implements from the power source to the point of load.
Some general recommendations to achieve matched array
impedances include:
n Provide as symmetric a PCB layout as possible among modules
n Apply same input / output filters (if present) to each unit.
For further details see AN:016 Using BCM Bus Converters
in High Power Arrays.
BCM®1
ZOUT_EQ1
R0_1
ZIN_EQ2
BCM®2
VOUT
ZOUT_EQ2
Load
ZIN_EQn
BCM®n
n Maximum voltage rating (usually greater than the maximum
possible input voltage)
n Ambient temperature
Reverse Operation
BCM® modules are capable of reverse power operation. Once the
unit is started, energy will be transferred from secondary back to
the primary whenever the secondary voltage exceeds VIN • K. The
module will continue operation in this fashion for as long as no
faults occur.
The BCM48Bx030y210A00 has not been qualified for continuous
operation in a reverse power condition. Furthermore fault
protections which help protect the module in forward operation
will not fully protect the module in reverse operation.
R0_2
+ DC
of BCM module)
n Recommend fuse: ≤ 10A Littlefuse Nano2 Fuse.
to deliver and return the current to the modules.
ZIN_EQ1
n Current rating (usually greater than maximum current
n Nominal melting I2t
n Dedicate common copper planes within the PCB
VIN
The fuse shall be selected by closely matching system
requirements with the following characteristics:
Transient operation in reverse is expected in cases where there is
significant energy storage on the output and transient voltages
appear on the input. Transient reverse power operation of less than
10ms, 10% duty cycle is permitted and has been qualified to cover
these cases.
ZOUT_EQn
R0_n
Figure 19 — BCM module array
BCM® Bus Converter
Page 16 of 20
Rev 1.5
08/2016
vicorpower.com
800 927.9474
BCM48Bx030y210A00
J-Lead Package Mechanical Drawing
mm
(inch)
NOTES:
mm
1. DIMENSIONS ARE inch .
2. UNLESS OTHERWISE SPECIFIED, TOLERANCES ARE:
.X / [.XX] = +/-0.25 / [.01]; .XX / [.XXX] = +/-0.13 / [.005]
NOTES:
mmTOP SURFACE
3. PRODUCT MARKING ON
1. DIMENSIONS ARE inch .
2. UNLESS OTHERWISE SPECIFIED, TOLERANCES ARE:
DXF and PDF files are available on vicorpower.com
.X / [.XX] = +/-0.25 / [.01]; .XX / [.XXX] = +/-0.13 / [.005]
3. PRODUCT MARKING ON TOP SURFACE
DXF and PDF files are available on vicorpower.com
J-Lead Package Recommended Land Pattern
NOTES:
mm
1. DIMENSIONS ARE inch .
2. UNLESS OTHERWISE SPECIFIED, TOLERANCES ARE:
.X / [.XX] = +/-0.25 / [.01]; .XX / [.XXX] = +/-0.13 / [.005]
NOTES:
mmTOP SURFACE
3. PRODUCT MARKING ON
1. DIMENSIONS ARE inch .
2. UNLESS OTHERWISE SPECIFIED, TOLERANCES ARE:
DXF and PDF files are available on vicorpower.com
.X / [.XX] = +/-0.25 / [.01]; .XX / [.XXX] = +/-0.13 / [.005]
3. PRODUCT MARKING ON TOP SURFACE
DXF and PDF files are available on vicorpower.com
BCM® Bus Converter
Page 17 of 20
Rev 1.5
08/2016
vicorpower.com
800 927.9474
BCM48Bx030y210A00
Through-Hole Package Mechanical Drawing
mm
(inch)
TOP VIEW ( COMPONENT SIDE )
TOP VIEW ( COMPONENT SIDE )
NOTES:
(mm)
NOTES:
1. DIMENSIONS ARE inch .
(mm)
1. DIMENSIONS
2. UNLESS ARE
OTHERWISE
inch . SPECIFIED TOLERANCES ARE:
X.X [X.XX] = ±0.25 [0.01]; X.XX [X.XXX] = ±0.13 [0.005]
2. UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:
X.X3.[X.XX]
±0.25 [0.01];PER
X.XXCST-0001
[X.XXX] =LATEST
±0.13 [0.005]
RoHS=COMPLIANT
REVISION
3. RoHS
LATEST
REVISION
DXFCOMPLIANT
and PDF filesPER
are CST-0001
available on
vicorpower.com
DXF and PDF files are available on vicorpower.com
Through-Hole Package Recommended Land Pattern
NOTES:
(mm)
NOTES:
1. DIMENSIONS ARE inch .
(mm)
1. DIMENSIONS
ARE
.
2. UNLESS OTHERWISE
SPECIFIED TOLERANCES ARE:
inch
X.X [X.XX] = ±0.25 [0.01]; X.XX [X.XXX] = ±0.13 [0.005]
2. UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:
X.X3.[X.XX]
=
±0.25
[0.01];
X.XX
[X.XXX] =LATEST
±0.13 [0.005]
RoHS COMPLIANT PER CST-0001
REVISION
RECOMMENDED HOLE PATTERN
( COMPONENT
SIDE
SHOWN )
RECOMMENDED
HOLE
PATTERN
( COMPONENT SIDE SHOWN )
3. RoHS
LATEST
REVISION
DXFCOMPLIANT
and PDF filesPER
are CST-0001
available on
vicorpower.com
DXF and PDF files are available on vicorpower.com
BCM® Bus Converter
Page 18 of 20
Rev 1.5
08/2016
vicorpower.com
800 927.9474
BOTTOM VIEW
BOTTOM VIEW
BCM48Bx030y210A00
Recommended Heat Sink Push Pin Location
(NO GROUNDING CLIPS)
(WITH GROUNDING CLIPS)
Notes:
1. Maintain 3.50 (0.138) Dia. keep-out zone
free of copper, all PCB layers.
2. (A) Minimum recommended pitch is 39.50 (1.555).
This provides 7.00 (0.275) component
edge-to-edge spacing, and 0.50 (0.020)
clearance between Vicor heat sinks.
(B) Minimum recommended pitch is 41.00 (1.614).
This provides 8.50 (0.334) component
edge-to-edge spacing, and 2.00 (0.079)
clearance between Vicor heat sinks.
BCM® Bus Converter
Page 19 of 20
3. VI Chip® module land pattern shown for reference
only; actual land pattern may differ.
Dimensions from edges of land pattern
to push–pin holes will be the same for
all full-size VI Chip® products.
5. Unless otherwise specified:
Dimensions are mm (inches)
tolerances are:
x.x (x.xx) = ±0.3 (0.01)
x.xx (x.xxx) = ±0.13 (0.005)
4. RoHS compliant per CST–0001 latest revision.
6. Plated through holes for grounding clips (33855)
shown for reference, heat sink orientation and
device pitch will dictate final grounding solution.
Rev 1.5
08/2016
vicorpower.com
800 927.9474
BCM48Bx030y210A00
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power
systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls
are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of
all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW)
WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY,
FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER
MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
The products described on this data sheet are protected by the following U.S. Patents Numbers:
5,945,130; 6,403,009; 6,710,257; 6,911,848; 6,930,893; 6,934,166; 6,940,013; 6,969,909; 7,038,917; 7,145,186; 7,166,898; 7,187,263;
7,202,646; 7,361,844; D496,906; D505,114; D506,438; D509,472; and for use under 6,975,098 and 6,984,965.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: [email protected]
Technical Support: [email protected]
BCM® Bus Converter
Page 20 of 20
Rev 1.5
08/2016
vicorpower.com
800 927.9474
Similar pages